ABAP Select data from SAP table RFKP6_INT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RFKP6_INT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RFKP6_INT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RFKP6_INT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RFKP6_INT TYPE STANDARD TABLE OF RFKP6_INT,
      WA_RFKP6_INT TYPE RFKP6_INT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RFKP6_INT> TYPE RFKP6_INT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RFKP6_INT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RFKP6_INT
  INTO TABLE IT_RFKP6_INT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RFKP6_INT
*  INTO TABLE @DATA(IT_RFKP6_INT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RFKP6_INT INDEX 1 INTO DATA(WA_RFKP6_INT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RFKP6_INT ASSIGNING <RFKP6_INT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RFKP6_INT>-TABIX = 1.
<RFKP6_INT>-XREPL = 1.
<RFKP6_INT>-OPSPZ = 1.
<RFKP6_INT>-XMARK = 1.
<RFKP6_INT>-DSTNR = 1.
ENDLOOP.

LOOP AT IT_RFKP6_INT INTO WA_RFKP6_INT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RFKP6_INT-ICON, sy-vline,
WA_RFKP6_INT-ICON2, sy-vline,
WA_RFKP6_INT-PRZNT, sy-vline,
WA_RFKP6_INT-ICON_LPAY, sy-vline,
WA_RFKP6_INT-ICON_LDUN, sy-vline,
WA_RFKP6_INT-ICON_LINT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RFKP6_INT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RFKP6_INT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RFKP6_INT INTO WA_RFKP6_INT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RFKP6_INT_STR,
TABIX TYPE STRING,
XREPL TYPE STRING,
OPSPZ TYPE STRING,
XMARK TYPE STRING,
DSTNR TYPE STRING,
ICON TYPE STRING,
ICON2 TYPE STRING,
PRZNT TYPE STRING,
ICON_LPAY TYPE STRING,
ICON_LDUN TYPE STRING,
ICON_LINT TYPE STRING,
ICON_LCLR TYPE STRING,
ICON_ESR TYPE STRING,
LICON TYPE STRING,END OF T_EKKO_STR. DATA: WA_RFKP6_INT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RFKP6_INT_STR-TABIX sy-vline
WA_RFKP6_INT_STR-XREPL sy-vline
WA_RFKP6_INT_STR-OPSPZ sy-vline
WA_RFKP6_INT_STR-XMARK sy-vline
WA_RFKP6_INT_STR-DSTNR sy-vline
WA_RFKP6_INT_STR-ICON sy-vline
WA_RFKP6_INT_STR-ICON2 sy-vline
WA_RFKP6_INT_STR-PRZNT sy-vline
WA_RFKP6_INT_STR-ICON_LPAY sy-vline
WA_RFKP6_INT_STR-ICON_LDUN sy-vline
WA_RFKP6_INT_STR-ICON_LINT sy-vline
WA_RFKP6_INT_STR-ICON_LCLR sy-vline
WA_RFKP6_INT_STR-ICON_ESR sy-vline
WA_RFKP6_INT_STR-LICON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.