ABAP Select data from SAP table RFKORD30_S_WT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RFKORD30_S_WT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RFKORD30_S_WT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RFKORD30_S_WT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RFKORD30_S_WT TYPE STANDARD TABLE OF RFKORD30_S_WT,
      WA_RFKORD30_S_WT TYPE RFKORD30_S_WT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RFKORD30_S_WT> TYPE RFKORD30_S_WT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RFKORD30_S_WT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RFKORD30_S_WT
  INTO TABLE IT_RFKORD30_S_WT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RFKORD30_S_WT
*  INTO TABLE @DATA(IT_RFKORD30_S_WT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RFKORD30_S_WT INDEX 1 INTO DATA(WA_RFKORD30_S_WT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RFKORD30_S_WT ASSIGNING <RFKORD30_S_WT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RFKORD30_S_WT>-WITHT = 1.
<RFKORD30_S_WT>-WITHTTXT = 1.
<RFKORD30_S_WT>-WT_WITHCD = 1.
<RFKORD30_S_WT>-WT_WITHCDTXT = 1.
<RFKORD30_S_WT>-WT_QSSHB = 1.
ENDLOOP.

LOOP AT IT_RFKORD30_S_WT INTO WA_RFKORD30_S_WT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RFKORD30_S_WT-WT_QBSHB, sy-vline,
WA_RFKORD30_S_WT-WT_BWAERS, sy-vline,
WA_RFKORD30_S_WT-BEZSHKZG, sy-vline,
WA_RFKORD30_S_WT-WT_QBSHH, sy-vline,
WA_RFKORD30_S_WT-WT_QSSHH, sy-vline,
WA_RFKORD30_S_WT-WT_HWAERS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RFKORD30_S_WT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RFKORD30_S_WT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RFKORD30_S_WT INTO WA_RFKORD30_S_WT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AC152, internal->external for field WT_QSSHB CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_RFKORD30_S_WT-WT_QSSHB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKORD30_S_WT-WT_QSSHB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBSHB CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_RFKORD30_S_WT-WT_QBSHB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKORD30_S_WT-WT_QBSHB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QBSHH CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_RFKORD30_S_WT-WT_QBSHH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKORD30_S_WT-WT_QBSHH.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC152, internal->external for field WT_QSSHH CALL FUNCTION 'CONVERSION_EXIT_AC152_OUTPUT' EXPORTING input = WA_RFKORD30_S_WT-WT_QSSHH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RFKORD30_S_WT-WT_QSSHH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RFKORD30_S_WT_STR,
WITHT TYPE STRING,
WITHTTXT TYPE STRING,
WT_WITHCD TYPE STRING,
WT_WITHCDTXT TYPE STRING,
WT_QSSHB TYPE STRING,
WT_QBSHB TYPE STRING,
WT_BWAERS TYPE STRING,
BEZSHKZG TYPE STRING,
WT_QBSHH TYPE STRING,
WT_QSSHH TYPE STRING,
WT_HWAERS TYPE STRING,END OF T_EKKO_STR. DATA: WA_RFKORD30_S_WT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RFKORD30_S_WT_STR-WITHT sy-vline
WA_RFKORD30_S_WT_STR-WITHTTXT sy-vline
WA_RFKORD30_S_WT_STR-WT_WITHCD sy-vline
WA_RFKORD30_S_WT_STR-WT_WITHCDTXT sy-vline
WA_RFKORD30_S_WT_STR-WT_QSSHB sy-vline
WA_RFKORD30_S_WT_STR-WT_QBSHB sy-vline
WA_RFKORD30_S_WT_STR-WT_BWAERS sy-vline
WA_RFKORD30_S_WT_STR-BEZSHKZG sy-vline
WA_RFKORD30_S_WT_STR-WT_QBSHH sy-vline
WA_RFKORD30_S_WT_STR-WT_QSSHH sy-vline
WA_RFKORD30_S_WT_STR-WT_HWAERS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.