ABAP Select data from SAP table RF61DBD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RF61DBD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RF61DBD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RF61DBD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RF61DBD TYPE STANDARD TABLE OF RF61DBD,
      WA_RF61DBD TYPE RF61DBD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RF61DBD> TYPE RF61DBD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RF61DBD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RF61DBD
  INTO TABLE IT_RF61DBD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RF61DBD
*  INTO TABLE @DATA(IT_RF61DBD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RF61DBD INDEX 1 INTO DATA(WA_RF61DBD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RF61DBD ASSIGNING <RF61DBD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RF61DBD>-REC_TYP = 1.
<RF61DBD>-ABRKDNR = 1.
<RF61DBD>-RZNR = 1.
<RF61DBD>-A1KONST = 1.
<RF61DBD>-STECHEM = 1.
ENDLOOP.

LOOP AT IT_RF61DBD INTO WA_RF61DBD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RF61DBD-ABRLTAG, sy-vline,
WA_RF61DBD-ABNNR, sy-vline,
WA_RF61DBD-ABRGKOST, sy-vline,
WA_RF61DBD-ABRGZAHL, sy-vline,
WA_RF61DBD-ABRSALDO, sy-vline,
WA_RF61DBD-ABRABN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RF61DBD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RF61DBD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RF61DBD INTO WA_RF61DBD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RF61DBD_STR,
REC_TYP TYPE STRING,
ABRKDNR TYPE STRING,
RZNR TYPE STRING,
A1KONST TYPE STRING,
STECHEM TYPE STRING,
ABRLTAG TYPE STRING,
ABNNR TYPE STRING,
ABRGKOST TYPE STRING,
ABRGZAHL TYPE STRING,
ABRSALDO TYPE STRING,
ABRABN TYPE STRING,
ABRSTTAG TYPE STRING,
ABRUMLWBTR TYPE STRING,
ABRWAERS TYPE STRING,
ABRNZAHL TYPE STRING,
ABRMWSTBTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_RF61DBD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RF61DBD_STR-REC_TYP sy-vline
WA_RF61DBD_STR-ABRKDNR sy-vline
WA_RF61DBD_STR-RZNR sy-vline
WA_RF61DBD_STR-A1KONST sy-vline
WA_RF61DBD_STR-STECHEM sy-vline
WA_RF61DBD_STR-ABRLTAG sy-vline
WA_RF61DBD_STR-ABNNR sy-vline
WA_RF61DBD_STR-ABRGKOST sy-vline
WA_RF61DBD_STR-ABRGZAHL sy-vline
WA_RF61DBD_STR-ABRSALDO sy-vline
WA_RF61DBD_STR-ABRABN sy-vline
WA_RF61DBD_STR-ABRSTTAG sy-vline
WA_RF61DBD_STR-ABRUMLWBTR sy-vline
WA_RF61DBD_STR-ABRWAERS sy-vline
WA_RF61DBD_STR-ABRNZAHL sy-vline
WA_RF61DBD_STR-ABRMWSTBTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.