ABAP Select data from SAP table RF140_S_CORR_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RF140_S_CORR_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RF140_S_CORR_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RF140_S_CORR_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RF140_S_CORR_DATA TYPE STANDARD TABLE OF RF140_S_CORR_DATA,
      WA_RF140_S_CORR_DATA TYPE RF140_S_CORR_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RF140_S_CORR_DATA> TYPE RF140_S_CORR_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RF140_S_CORR_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RF140_S_CORR_DATA
  INTO TABLE IT_RF140_S_CORR_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RF140_S_CORR_DATA
*  INTO TABLE @DATA(IT_RF140_S_CORR_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RF140_S_CORR_DATA INDEX 1 INTO DATA(WA_RF140_S_CORR_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RF140_S_CORR_DATA ASSIGNING <RF140_S_CORR_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RF140_S_CORR_DATA>-MANDT_BK = 1.
<RF140_S_CORR_DATA>-EVENT_BK = 1.
<RF140_S_CORR_DATA>-BUKRS_BK = 1.
<RF140_S_CORR_DATA>-KOART_BK = 1.
<RF140_S_CORR_DATA>-KONTO_BK = 1.
ENDLOOP.

LOOP AT IT_RF140_S_CORR_DATA INTO WA_RF140_S_CORR_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RF140_S_CORR_DATA-BELNR_BK, sy-vline,
WA_RF140_S_CORR_DATA-GJAHR_BK, sy-vline,
WA_RF140_S_CORR_DATA-USNAM_BK, sy-vline,
WA_RF140_S_CORR_DATA-DATUM_BK, sy-vline,
WA_RF140_S_CORR_DATA-UZEIT_BK, sy-vline,
WA_RF140_S_CORR_DATA-ERLDT_BK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RF140_S_CORR_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RF140_S_CORR_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RF140_S_CORR_DATA INTO WA_RF140_S_CORR_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KONTO_BK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RF140_S_CORR_DATA-KONTO_BK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RF140_S_CORR_DATA-KONTO_BK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR_BK CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RF140_S_CORR_DATA-BELNR_BK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RF140_S_CORR_DATA-BELNR_BK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR_BK CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_RF140_S_CORR_DATA-GJAHR_BK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RF140_S_CORR_DATA-GJAHR_BK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KONTO_AD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RF140_S_CORR_DATA-KONTO_AD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RF140_S_CORR_DATA-KONTO_AD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ADRNR_AD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RF140_S_CORR_DATA-ADRNR_AD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RF140_S_CORR_DATA-ADRNR_AD.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS_FS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_RF140_S_CORR_DATA-SPRAS_FS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RF140_S_CORR_DATA-SPRAS_FS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field MAIL_SEND_ADDR_AA CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_RF140_S_CORR_DATA-MAIL_SEND_ADDR_AA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RF140_S_CORR_DATA-MAIL_SEND_ADDR_AA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MAIL_BOR_LOGSYS_AA CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RF140_S_CORR_DATA-MAIL_BOR_LOGSYS_AA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RF140_S_CORR_DATA-MAIL_BOR_LOGSYS_AA.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RF140_S_CORR_DATA_STR,
MANDT_BK TYPE STRING,
EVENT_BK TYPE STRING,
BUKRS_BK TYPE STRING,
KOART_BK TYPE STRING,
KONTO_BK TYPE STRING,
BELNR_BK TYPE STRING,
GJAHR_BK TYPE STRING,
USNAM_BK TYPE STRING,
DATUM_BK TYPE STRING,
UZEIT_BK TYPE STRING,
ERLDT_BK TYPE STRING,
PARAM_BK TYPE STRING,
AVSID_BK TYPE STRING,
BBUKR_BK TYPE STRING,
CAJON_BK TYPE STRING,
KOART TYPE STRING,
ANRED_AD TYPE STRING,
NAME1_AD TYPE STRING,
NAME2_AD TYPE STRING,
NAME3_AD TYPE STRING,
NAME4_AD TYPE STRING,
STRAS_AD TYPE STRING,
PFACH_AD TYPE STRING,
PSTL2_AD TYPE STRING,
PFORT_AD TYPE STRING,
LAND1_AD TYPE STRING,
PSTLZ_AD TYPE STRING,
ORT01_AD TYPE STRING,
ORT02_AD TYPE STRING,
REGIO_AD TYPE STRING,
INLND_AD TYPE STRING,
KONTO_AD TYPE STRING,
EIKTO_AD TYPE STRING,
ZSABE_AD TYPE STRING,
ADRNR_AD TYPE STRING,
BUKRS_FS TYPE STRING,
SALUT_FS TYPE STRING,
FNAME_FS TYPE STRING,
LNAME_FS TYPE STRING,
NAMP1_FS TYPE STRING,
NAMP2_FS TYPE STRING,
ID_CODE_FS TYPE STRING,
SPRAS_FS TYPE STRING,
ABTEI_FS TYPE STRING,
FUNCTION_FS TYPE STRING,
KOSTL_FS TYPE STRING,
ROOMN_FS TYPE STRING,
BUILD_FS TYPE STRING,
FLOOR_C_FS TYPE STRING,
IH_MAIL_FS TYPE STRING,
TELF1_FS TYPE STRING,
TEL_EXTEN1_FS TYPE STRING,
TELF2_FS TYPE STRING,
TEL_EXTEN2_FS TYPE STRING,
TELFX_FS TYPE STRING,
FAX_EXTENS_FS TYPE STRING,
INTAD_FS TYPE STRING,
USRNAM_FS TYPE STRING,
COUNTRY_TEL_FS TYPE STRING,
TELNR_LONG_FS TYPE STRING,
COUNTRY_FAX_FS TYPE STRING,
FAXNR_LONG_FS TYPE STRING,
COUNTRY_FS TYPE STRING,
NACHA_AA TYPE STRING,
TDSCHEDULE_AA TYPE STRING,
TDTELELAND_AA TYPE STRING,
TDTELENUM_AA TYPE STRING,
INTAD_AA TYPE STRING,
NAMEP_AA TYPE STRING,
ABTEI_AA TYPE STRING,
FORMC_AA TYPE STRING,
FORNR_AA TYPE STRING,
TEXTF_AA TYPE STRING,
TDFAXUSER_AA TYPE STRING,
INTUSER_AA TYPE STRING,
MAIL_SENSITIVITY_AA TYPE STRING,
MAIL_IMPORTANCE_AA TYPE STRING,
MAIL_SEND_PRIO_AA TYPE STRING,
MAIL_SEND_ADDR_AA TYPE STRING,
MAIL_STATUS_ATTR_AA TYPE STRING,
MAIL_BODY_FORMAT_AA TYPE STRING,
MAIL_BODY_TEXT_AA TYPE STRING,
MAIL_OUTBOX_LINK_AA TYPE STRING,
MAIL_EXPIRES_ON_AA TYPE STRING,
MAIL_BOR_OBJKEY_AA TYPE STRING,
MAIL_BOR_OBJTYPE_AA TYPE STRING,
MAIL_BOR_LOGSYS_AA TYPE STRING,
INTAD_CC_AA TYPE STRING,
INTAD_BCC_AA TYPE STRING,
SEND_FAX_WITH_CL_BCS_AA TYPE STRING,
MAIL_SIGN_AA TYPE STRING,
MAIL_ENCRYPT_AA TYPE STRING,
BIN_FILE TYPE STRING,
MAIL_SUBJECT TYPE STRING,
MAIL_BODY_ENTERED TYPE STRING,
MAIL_BODY TYPE STRING,END OF T_EKKO_STR. DATA: WA_RF140_S_CORR_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RF140_S_CORR_DATA_STR-MANDT_BK sy-vline
WA_RF140_S_CORR_DATA_STR-EVENT_BK sy-vline
WA_RF140_S_CORR_DATA_STR-BUKRS_BK sy-vline
WA_RF140_S_CORR_DATA_STR-KOART_BK sy-vline
WA_RF140_S_CORR_DATA_STR-KONTO_BK sy-vline
WA_RF140_S_CORR_DATA_STR-BELNR_BK sy-vline
WA_RF140_S_CORR_DATA_STR-GJAHR_BK sy-vline
WA_RF140_S_CORR_DATA_STR-USNAM_BK sy-vline
WA_RF140_S_CORR_DATA_STR-DATUM_BK sy-vline
WA_RF140_S_CORR_DATA_STR-UZEIT_BK sy-vline
WA_RF140_S_CORR_DATA_STR-ERLDT_BK sy-vline
WA_RF140_S_CORR_DATA_STR-PARAM_BK sy-vline
WA_RF140_S_CORR_DATA_STR-AVSID_BK sy-vline
WA_RF140_S_CORR_DATA_STR-BBUKR_BK sy-vline
WA_RF140_S_CORR_DATA_STR-CAJON_BK sy-vline
WA_RF140_S_CORR_DATA_STR-KOART sy-vline
WA_RF140_S_CORR_DATA_STR-ANRED_AD sy-vline
WA_RF140_S_CORR_DATA_STR-NAME1_AD sy-vline
WA_RF140_S_CORR_DATA_STR-NAME2_AD sy-vline
WA_RF140_S_CORR_DATA_STR-NAME3_AD sy-vline
WA_RF140_S_CORR_DATA_STR-NAME4_AD sy-vline
WA_RF140_S_CORR_DATA_STR-STRAS_AD sy-vline
WA_RF140_S_CORR_DATA_STR-PFACH_AD sy-vline
WA_RF140_S_CORR_DATA_STR-PSTL2_AD sy-vline
WA_RF140_S_CORR_DATA_STR-PFORT_AD sy-vline
WA_RF140_S_CORR_DATA_STR-LAND1_AD sy-vline
WA_RF140_S_CORR_DATA_STR-PSTLZ_AD sy-vline
WA_RF140_S_CORR_DATA_STR-ORT01_AD sy-vline
WA_RF140_S_CORR_DATA_STR-ORT02_AD sy-vline
WA_RF140_S_CORR_DATA_STR-REGIO_AD sy-vline
WA_RF140_S_CORR_DATA_STR-INLND_AD sy-vline
WA_RF140_S_CORR_DATA_STR-KONTO_AD sy-vline
WA_RF140_S_CORR_DATA_STR-EIKTO_AD sy-vline
WA_RF140_S_CORR_DATA_STR-ZSABE_AD sy-vline
WA_RF140_S_CORR_DATA_STR-ADRNR_AD sy-vline
WA_RF140_S_CORR_DATA_STR-BUKRS_FS sy-vline
WA_RF140_S_CORR_DATA_STR-SALUT_FS sy-vline
WA_RF140_S_CORR_DATA_STR-FNAME_FS sy-vline
WA_RF140_S_CORR_DATA_STR-LNAME_FS sy-vline
WA_RF140_S_CORR_DATA_STR-NAMP1_FS sy-vline
WA_RF140_S_CORR_DATA_STR-NAMP2_FS sy-vline
WA_RF140_S_CORR_DATA_STR-ID_CODE_FS sy-vline
WA_RF140_S_CORR_DATA_STR-SPRAS_FS sy-vline
WA_RF140_S_CORR_DATA_STR-ABTEI_FS sy-vline
WA_RF140_S_CORR_DATA_STR-FUNCTION_FS sy-vline
WA_RF140_S_CORR_DATA_STR-KOSTL_FS sy-vline
WA_RF140_S_CORR_DATA_STR-ROOMN_FS sy-vline
WA_RF140_S_CORR_DATA_STR-BUILD_FS sy-vline
WA_RF140_S_CORR_DATA_STR-FLOOR_C_FS sy-vline
WA_RF140_S_CORR_DATA_STR-IH_MAIL_FS sy-vline
WA_RF140_S_CORR_DATA_STR-TELF1_FS sy-vline
WA_RF140_S_CORR_DATA_STR-TEL_EXTEN1_FS sy-vline
WA_RF140_S_CORR_DATA_STR-TELF2_FS sy-vline
WA_RF140_S_CORR_DATA_STR-TEL_EXTEN2_FS sy-vline
WA_RF140_S_CORR_DATA_STR-TELFX_FS sy-vline
WA_RF140_S_CORR_DATA_STR-FAX_EXTENS_FS sy-vline
WA_RF140_S_CORR_DATA_STR-INTAD_FS sy-vline
WA_RF140_S_CORR_DATA_STR-USRNAM_FS sy-vline
WA_RF140_S_CORR_DATA_STR-COUNTRY_TEL_FS sy-vline
WA_RF140_S_CORR_DATA_STR-TELNR_LONG_FS sy-vline
WA_RF140_S_CORR_DATA_STR-COUNTRY_FAX_FS sy-vline
WA_RF140_S_CORR_DATA_STR-FAXNR_LONG_FS sy-vline
WA_RF140_S_CORR_DATA_STR-COUNTRY_FS sy-vline
WA_RF140_S_CORR_DATA_STR-NACHA_AA sy-vline
WA_RF140_S_CORR_DATA_STR-TDSCHEDULE_AA sy-vline
WA_RF140_S_CORR_DATA_STR-TDTELELAND_AA sy-vline
WA_RF140_S_CORR_DATA_STR-TDTELENUM_AA sy-vline
WA_RF140_S_CORR_DATA_STR-INTAD_AA sy-vline
WA_RF140_S_CORR_DATA_STR-NAMEP_AA sy-vline
WA_RF140_S_CORR_DATA_STR-ABTEI_AA sy-vline
WA_RF140_S_CORR_DATA_STR-FORMC_AA sy-vline
WA_RF140_S_CORR_DATA_STR-FORNR_AA sy-vline
WA_RF140_S_CORR_DATA_STR-TEXTF_AA sy-vline
WA_RF140_S_CORR_DATA_STR-TDFAXUSER_AA sy-vline
WA_RF140_S_CORR_DATA_STR-INTUSER_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_SENSITIVITY_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_IMPORTANCE_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_SEND_PRIO_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_SEND_ADDR_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_STATUS_ATTR_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_BODY_FORMAT_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_BODY_TEXT_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_OUTBOX_LINK_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_EXPIRES_ON_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_BOR_OBJKEY_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_BOR_OBJTYPE_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_BOR_LOGSYS_AA sy-vline
WA_RF140_S_CORR_DATA_STR-INTAD_CC_AA sy-vline
WA_RF140_S_CORR_DATA_STR-INTAD_BCC_AA sy-vline
WA_RF140_S_CORR_DATA_STR-SEND_FAX_WITH_CL_BCS_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_SIGN_AA sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_ENCRYPT_AA sy-vline
WA_RF140_S_CORR_DATA_STR-BIN_FILE sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_SUBJECT sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_BODY_ENTERED sy-vline
WA_RF140_S_CORR_DATA_STR-MAIL_BODY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.