ABAP Select data from SAP table RF10A into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RF10A table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RF10A. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RF10A table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RF10A TYPE STANDARD TABLE OF RF10A,
      WA_RF10A TYPE RF10A,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RF10A> TYPE RF10A.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RF10A.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RF10A
  INTO TABLE IT_RF10A.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RF10A
*  INTO TABLE @DATA(IT_RF10A2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RF10A INDEX 1 INTO DATA(WA_RF10A2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RF10A ASSIGNING <RF10A>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RF10A>-TKEIN = 1.
<RF10A>-TKEIN_TXT = 1.
<RF10A>-SELTXT1 = 1.
<RF10A>-SELTXT2 = 1.
<RF10A>-SELTXT3 = 1.
ENDLOOP.

LOOP AT IT_RF10A INTO WA_RF10A.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RF10A-SELLAND, sy-vline,
WA_RF10A-TBL_HDL, sy-vline,
WA_RF10A-FKT_ID, sy-vline,
WA_RF10A-SEL, sy-vline,
WA_RF10A-INPUT, sy-vline,
WA_RF10A-INP_OPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RF10A you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RF10A TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RF10A INTO WA_RF10A. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RF10A_STR,
TKEIN TYPE STRING,
TKEIN_TXT TYPE STRING,
SELTXT1 TYPE STRING,
SELTXT2 TYPE STRING,
SELTXT3 TYPE STRING,
SELLAND TYPE STRING,
TBL_HDL TYPE STRING,
FKT_ID TYPE STRING,
SEL TYPE STRING,
INPUT TYPE STRING,
INP_OPE TYPE STRING,
INP_AKT TYPE STRING,
INP_BLC TYPE STRING,
POST TYPE STRING,
POST_OPE TYPE STRING,
POST_AKT TYPE STRING,
POST_BLC TYPE STRING,
CURR TYPE STRING,
CURR_OPE TYPE STRING,
CURR_AKT TYPE STRING,
CURR_BLC TYPE STRING,END OF T_EKKO_STR. DATA: WA_RF10A_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RF10A_STR-TKEIN sy-vline
WA_RF10A_STR-TKEIN_TXT sy-vline
WA_RF10A_STR-SELTXT1 sy-vline
WA_RF10A_STR-SELTXT2 sy-vline
WA_RF10A_STR-SELTXT3 sy-vline
WA_RF10A_STR-SELLAND sy-vline
WA_RF10A_STR-TBL_HDL sy-vline
WA_RF10A_STR-FKT_ID sy-vline
WA_RF10A_STR-SEL sy-vline
WA_RF10A_STR-INPUT sy-vline
WA_RF10A_STR-INP_OPE sy-vline
WA_RF10A_STR-INP_AKT sy-vline
WA_RF10A_STR-INP_BLC sy-vline
WA_RF10A_STR-POST sy-vline
WA_RF10A_STR-POST_OPE sy-vline
WA_RF10A_STR-POST_AKT sy-vline
WA_RF10A_STR-POST_BLC sy-vline
WA_RF10A_STR-CURR sy-vline
WA_RF10A_STR-CURR_OPE sy-vline
WA_RF10A_STR-CURR_AKT sy-vline
WA_RF10A_STR-CURR_BLC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.