ABAP Select data from SAP table REVMGT_FKKKO_FIELDS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP REVMGT_FKKKO_FIELDS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to REVMGT_FKKKO_FIELDS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the REVMGT_FKKKO_FIELDS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_REVMGT_FKKKO_FIELDS TYPE STANDARD TABLE OF REVMGT_FKKKO_FIELDS,
      WA_REVMGT_FKKKO_FIELDS TYPE REVMGT_FKKKO_FIELDS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <REVMGT_FKKKO_FIELDS> TYPE REVMGT_FKKKO_FIELDS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_REVMGT_FKKKO_FIELDS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM REVMGT_FKKKO_FIELDS
  INTO TABLE IT_REVMGT_FKKKO_FIELDS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM REVMGT_FKKKO_FIELDS
*  INTO TABLE @DATA(IT_REVMGT_FKKKO_FIELDS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_REVMGT_FKKKO_FIELDS INDEX 1 INTO DATA(WA_REVMGT_FKKKO_FIELDS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_REVMGT_FKKKO_FIELDS ASSIGNING <REVMGT_FKKKO_FIELDS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<REVMGT_FKKKO_FIELDS>-FIKEY = 1.
<REVMGT_FKKKO_FIELDS>-ERNAM = 1.
<REVMGT_FKKKO_FIELDS>-WWERT = 1.
<REVMGT_FKKKO_FIELDS>-ABGRD = 1.
<REVMGT_FKKKO_FIELDS>-XEIBH = 1.
ENDLOOP.

LOOP AT IT_REVMGT_FKKKO_FIELDS INTO WA_REVMGT_FKKKO_FIELDS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_REVMGT_FKKKO_FIELDS-XBWER, sy-vline,
WA_REVMGT_FKKKO_FIELDS-AWTYP, sy-vline,
WA_REVMGT_FKKKO_FIELDS-AWKEY, sy-vline,
WA_REVMGT_FKKKO_FIELDS-STBEL, sy-vline,
WA_REVMGT_FKKKO_FIELDS-BLTYP, sy-vline,
WA_REVMGT_FKKKO_FIELDS-AGINF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_REVMGT_FKKKO_FIELDS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_REVMGT_FKKKO_FIELDS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_REVMGT_FKKKO_FIELDS INTO WA_REVMGT_FKKKO_FIELDS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field STBEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REVMGT_FKKKO_FIELDS-STBEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REVMGT_FKKKO_FIELDS-STBEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field STORB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REVMGT_FKKKO_FIELDS-STORB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REVMGT_FKKKO_FIELDS-STORB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AWSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REVMGT_FKKKO_FIELDS-AWSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REVMGT_FKKKO_FIELDS-AWSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_REVMGT_FKKKO_FIELDS_STR,
FIKEY TYPE STRING,
ERNAM TYPE STRING,
WWERT TYPE STRING,
ABGRD TYPE STRING,
XEIBH TYPE STRING,
XBWER TYPE STRING,
AWTYP TYPE STRING,
AWKEY TYPE STRING,
STBEL TYPE STRING,
BLTYP TYPE STRING,
AGINF TYPE STRING,
STBUK TYPE STRING,
STORB TYPE STRING,
APPDX TYPE STRING,
AWSYS TYPE STRING,END OF T_EKKO_STR. DATA: WA_REVMGT_FKKKO_FIELDS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-FIKEY sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-ERNAM sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-WWERT sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-ABGRD sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-XEIBH sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-XBWER sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-AWTYP sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-AWKEY sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-STBEL sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-BLTYP sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-AGINF sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-STBUK sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-STORB sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-APPDX sy-vline
WA_REVMGT_FKKKO_FIELDS_STR-AWSYS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.