ABAP Select data from SAP table REVAL_6B into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP REVAL_6B table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to REVAL_6B. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the REVAL_6B table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_REVAL_6B TYPE STANDARD TABLE OF REVAL_6B,
      WA_REVAL_6B TYPE REVAL_6B,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <REVAL_6B> TYPE REVAL_6B.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_REVAL_6B.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM REVAL_6B
  INTO TABLE IT_REVAL_6B.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM REVAL_6B
*  INTO TABLE @DATA(IT_REVAL_6B2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_REVAL_6B INDEX 1 INTO DATA(WA_REVAL_6B2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_REVAL_6B ASSIGNING <REVAL_6B>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<REVAL_6B>-BUKRS = 1.
<REVAL_6B>-RLDEPO = 1.
<REVAL_6B>-RANL = 1.
<REVAL_6B>-BBEZUGWR = 1.
<REVAL_6B>-BBEZUGHW = 1.
ENDLOOP.

LOOP AT IT_REVAL_6B INTO WA_REVAL_6B.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_REVAL_6B-SCWHR, sy-vline,
WA_REVAL_6B-JIREC, sy-vline,
WA_REVAL_6B-RLDEPO_N, sy-vline,
WA_REVAL_6B-RANL_N, sy-vline,
WA_REVAL_6B-ASTUECK_N, sy-vline,
WA_REVAL_6B-BNOMINAL_N, sy-vline.
ENDLOOP. *Add any further fields from structure WA_REVAL_6B you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_REVAL_6B TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_REVAL_6B INTO WA_REVAL_6B. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RANL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REVAL_6B-RANL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REVAL_6B-RANL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RANL_N CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REVAL_6B-RANL_N IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REVAL_6B-RANL_N.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RANL_OS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REVAL_6B-RANL_OS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REVAL_6B-RANL_OS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field FW_ANKURS CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_REVAL_6B-FW_ANKURS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REVAL_6B-FW_ANKURS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field FW_BUKURS CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_REVAL_6B-FW_BUKURS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REVAL_6B-FW_BUKURS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field FW_BEKURS CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_REVAL_6B-FW_BEKURS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REVAL_6B-FW_BEKURS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_REVAL_6B_STR,
BUKRS TYPE STRING,
RLDEPO TYPE STRING,
RANL TYPE STRING,
BBEZUGWR TYPE STRING,
BBEZUGHW TYPE STRING,
SCWHR TYPE STRING,
JIREC TYPE STRING,
RLDEPO_N TYPE STRING,
RANL_N TYPE STRING,
ASTUECK_N TYPE STRING,
BNOMINAL_N TYPE STRING,
RANL_OS TYPE STRING,
ASTUECK_OS TYPE STRING,
AJUNG TYPE STRING,
ABEZ TYPE STRING,
BBABD_AN TYPE STRING,
EBBABD_AN TYPE STRING,
BBABD_BU TYPE STRING,
EBBABD_BU TYPE STRING,
BJUNGD TYPE STRING,
EBJUNGD TYPE STRING,
FW_ANKURS TYPE STRING,
FW_BUKURS TYPE STRING,
FW_BEKURS TYPE STRING,
KURS_CUM_P TYPE STRING,
KURS_CUM_B TYPE STRING,
KURS_CUM_D TYPE STRING,
KURS_OS_B TYPE STRING,
KURS_OS_D TYPE STRING,
KURS_EX_B TYPE STRING,
KURS_EX_P TYPE STRING,
DBEST6B TYPE STRING,
NORDER TYPE STRING,
BNOMINAL TYPE STRING,
ASTUECK TYPE STRING,
SBWHR TYPE STRING,
SHWHR TYPE STRING,
BKAUFWR TYPE STRING,
BKAUFHW TYPE STRING,
BBUCHWR TYPE STRING,
BBUCHHW TYPE STRING,
BKOSTWR TYPE STRING,
BKOSTHW TYPE STRING,
BKSTBWR TYPE STRING,
BKSTBHW TYPE STRING,
BKSTAWR TYPE STRING,
BKSTAHW TYPE STRING,
BACTLWR TYPE STRING,
BACTLHW TYPE STRING,
BWPBWWR TYPE STRING,
BWPBWHW TYPE STRING,
BFWBWHW TYPE STRING,
BKOBWWR TYPE STRING,
BKOBWHW TYPE STRING,
BKOFBHW TYPE STRING,
BWPAEWR TYPE STRING,
BWPAEHW TYPE STRING,
BFWAEHW TYPE STRING,
BAMT1WR TYPE STRING,
BAMT1HW TYPE STRING,
BAMT2WR TYPE STRING,
BAMT2HW TYPE STRING,
BAMT3WR TYPE STRING,
BAMT3HW TYPE STRING,
BAMT4WR TYPE STRING,
BAMT4HW TYPE STRING,END OF T_EKKO_STR. DATA: WA_REVAL_6B_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_REVAL_6B_STR-BUKRS sy-vline
WA_REVAL_6B_STR-RLDEPO sy-vline
WA_REVAL_6B_STR-RANL sy-vline
WA_REVAL_6B_STR-BBEZUGWR sy-vline
WA_REVAL_6B_STR-BBEZUGHW sy-vline
WA_REVAL_6B_STR-SCWHR sy-vline
WA_REVAL_6B_STR-JIREC sy-vline
WA_REVAL_6B_STR-RLDEPO_N sy-vline
WA_REVAL_6B_STR-RANL_N sy-vline
WA_REVAL_6B_STR-ASTUECK_N sy-vline
WA_REVAL_6B_STR-BNOMINAL_N sy-vline
WA_REVAL_6B_STR-RANL_OS sy-vline
WA_REVAL_6B_STR-ASTUECK_OS sy-vline
WA_REVAL_6B_STR-AJUNG sy-vline
WA_REVAL_6B_STR-ABEZ sy-vline
WA_REVAL_6B_STR-BBABD_AN sy-vline
WA_REVAL_6B_STR-EBBABD_AN sy-vline
WA_REVAL_6B_STR-BBABD_BU sy-vline
WA_REVAL_6B_STR-EBBABD_BU sy-vline
WA_REVAL_6B_STR-BJUNGD sy-vline
WA_REVAL_6B_STR-EBJUNGD sy-vline
WA_REVAL_6B_STR-FW_ANKURS sy-vline
WA_REVAL_6B_STR-FW_BUKURS sy-vline
WA_REVAL_6B_STR-FW_BEKURS sy-vline
WA_REVAL_6B_STR-KURS_CUM_P sy-vline
WA_REVAL_6B_STR-KURS_CUM_B sy-vline
WA_REVAL_6B_STR-KURS_CUM_D sy-vline
WA_REVAL_6B_STR-KURS_OS_B sy-vline
WA_REVAL_6B_STR-KURS_OS_D sy-vline
WA_REVAL_6B_STR-KURS_EX_B sy-vline
WA_REVAL_6B_STR-KURS_EX_P sy-vline
WA_REVAL_6B_STR-DBEST6B sy-vline
WA_REVAL_6B_STR-NORDER sy-vline
WA_REVAL_6B_STR-BNOMINAL sy-vline
WA_REVAL_6B_STR-ASTUECK sy-vline
WA_REVAL_6B_STR-SBWHR sy-vline
WA_REVAL_6B_STR-SHWHR sy-vline
WA_REVAL_6B_STR-BKAUFWR sy-vline
WA_REVAL_6B_STR-BKAUFHW sy-vline
WA_REVAL_6B_STR-BBUCHWR sy-vline
WA_REVAL_6B_STR-BBUCHHW sy-vline
WA_REVAL_6B_STR-BKOSTWR sy-vline
WA_REVAL_6B_STR-BKOSTHW sy-vline
WA_REVAL_6B_STR-BKSTBWR sy-vline
WA_REVAL_6B_STR-BKSTBHW sy-vline
WA_REVAL_6B_STR-BKSTAWR sy-vline
WA_REVAL_6B_STR-BKSTAHW sy-vline
WA_REVAL_6B_STR-BACTLWR sy-vline
WA_REVAL_6B_STR-BACTLHW sy-vline
WA_REVAL_6B_STR-BWPBWWR sy-vline
WA_REVAL_6B_STR-BWPBWHW sy-vline
WA_REVAL_6B_STR-BFWBWHW sy-vline
WA_REVAL_6B_STR-BKOBWWR sy-vline
WA_REVAL_6B_STR-BKOBWHW sy-vline
WA_REVAL_6B_STR-BKOFBHW sy-vline
WA_REVAL_6B_STR-BWPAEWR sy-vline
WA_REVAL_6B_STR-BWPAEHW sy-vline
WA_REVAL_6B_STR-BFWAEHW sy-vline
WA_REVAL_6B_STR-BAMT1WR sy-vline
WA_REVAL_6B_STR-BAMT1HW sy-vline
WA_REVAL_6B_STR-BAMT2WR sy-vline
WA_REVAL_6B_STR-BAMT2HW sy-vline
WA_REVAL_6B_STR-BAMT3WR sy-vline
WA_REVAL_6B_STR-BAMT3HW sy-vline
WA_REVAL_6B_STR-BAMT4WR sy-vline
WA_REVAL_6B_STR-BAMT4HW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.