ABAP Select data from SAP table RESC_SETTL_UNIT_SET into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RESC_SETTL_UNIT_SET table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RESC_SETTL_UNIT_SET. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RESC_SETTL_UNIT_SET table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RESC_SETTL_UNIT_SET TYPE STANDARD TABLE OF RESC_SETTL_UNIT_SET,
      WA_RESC_SETTL_UNIT_SET TYPE RESC_SETTL_UNIT_SET,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RESC_SETTL_UNIT_SET> TYPE RESC_SETTL_UNIT_SET.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RESC_SETTL_UNIT_SET.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RESC_SETTL_UNIT_SET
  INTO TABLE IT_RESC_SETTL_UNIT_SET.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RESC_SETTL_UNIT_SET
*  INTO TABLE @DATA(IT_RESC_SETTL_UNIT_SET2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RESC_SETTL_UNIT_SET INDEX 1 INTO DATA(WA_RESC_SETTL_UNIT_SET2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RESC_SETTL_UNIT_SET ASSIGNING <RESC_SETTL_UNIT_SET>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RESC_SETTL_UNIT_SET>-MANDT = 1.
<RESC_SETTL_UNIT_SET>-INTRENO = 1.
<RESC_SETTL_UNIT_SET>-BUKRS = 1.
<RESC_SETTL_UNIT_SET>-SWENR = 1.
<RESC_SETTL_UNIT_SET>-SNKSL = 1.
ENDLOOP.

LOOP AT IT_RESC_SETTL_UNIT_SET INTO WA_RESC_SETTL_UNIT_SET.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RESC_SETTL_UNIT_SET-SEMPSL, sy-vline,
WA_RESC_SETTL_UNIT_SET-OBJNR, sy-vline,
WA_RESC_SETTL_UNIT_SET-IMKEY, sy-vline,
WA_RESC_SETTL_UNIT_SET-CREATIONTYPE, sy-vline,
WA_RESC_SETTL_UNIT_SET-RERF, sy-vline,
WA_RESC_SETTL_UNIT_SET-DERF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RESC_SETTL_UNIT_SET you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RESC_SETTL_UNIT_SET TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RESC_SETTL_UNIT_SET INTO WA_RESC_SETTL_UNIT_SET. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SWENR, internal->external for field SWENR CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_RESC_SETTL_UNIT_SET-SWENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_SETTL_UNIT_SET-SWENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SNKSL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RESC_SETTL_UNIT_SET-SNKSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_SETTL_UNIT_SET-SNKSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEMPSL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RESC_SETTL_UNIT_SET-SEMPSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_SETTL_UNIT_SET-SEMPSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit IMKEY, internal->external for field IMKEY CALL FUNCTION 'CONVERSION_EXIT_IMKEY_OUTPUT' EXPORTING input = WA_RESC_SETTL_UNIT_SET-IMKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_SETTL_UNIT_SET-IMKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RESC_SETTL_UNIT_SET-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_SETTL_UNIT_SET-VALIDTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field CORRVALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RESC_SETTL_UNIT_SET-CORRVALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_SETTL_UNIT_SET-CORRVALIDTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field PTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RESC_SETTL_UNIT_SET-PTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_SETTL_UNIT_SET-PTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RESC_SETTL_UNIT_SET-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_SETTL_UNIT_SET-PRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SCKEYGRP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RESC_SETTL_UNIT_SET-SCKEYGRP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_SETTL_UNIT_SET-SCKEYGRP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RESC_SETTL_UNIT_SET_STR,
MANDT TYPE STRING,
INTRENO TYPE STRING,
BUKRS TYPE STRING,
SWENR TYPE STRING,
SNKSL TYPE STRING,
SEMPSL TYPE STRING,
OBJNR TYPE STRING,
IMKEY TYPE STRING,
CREATIONTYPE TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
RESPONSIBLE TYPE STRING,
USEREXCLUSIVE TYPE STRING,
AUTHGRP TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
SUTYPE TYPE STRING,
XSU TYPE STRING,
TENANCYLAW TYPE STRING,
HASCOSTOBJECT TYPE STRING,
NOTAXCORR TYPE STRING,
EXCHANGETYPE TYPE STRING,
SETTLADVPAY TYPE STRING,
PERHEATING TYPE STRING,
PERHOTWATER TYPE STRING,
MSUCROSSOVERCC TYPE STRING,
CORRSU TYPE STRING,
CORRINTRENO TYPE STRING,
CORRVALIDFROM TYPE STRING,
CORRVALIDTO TYPE STRING,
SUEXTFORSCS TYPE STRING,
BUTXT TYPE STRING,
XWETEXT TYPE STRING,
XSCKEY TYPE STRING,
SETTLVARIANT TYPE STRING,
PFROM TYPE STRING,
PTO TYPE STRING,
PROCESSID TYPE STRING,
PROCESSEXTID TYPE STRING,
XSTATUS TYPE STRING,
VALIDITY TYPE STRING,
XAUTHGRP TYPE STRING,
GSBER TYPE STRING,
PRCTR TYPE STRING,
COST_INDICATOR TYPE STRING,
IS_APPORTIONABLE TYPE STRING,
ONLY_COMMERCIAL TYPE STRING,
USE_HEATDAYS TYPE STRING,
DIRECTCOSTID TYPE STRING,
CREDITGLACCSYMB TYPE STRING,
SCKEYPROCIND TYPE STRING,
SCKEYGRP TYPE STRING,
XSCKEYGRP TYPE STRING,END OF T_EKKO_STR. DATA: WA_RESC_SETTL_UNIT_SET_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RESC_SETTL_UNIT_SET_STR-MANDT sy-vline
WA_RESC_SETTL_UNIT_SET_STR-INTRENO sy-vline
WA_RESC_SETTL_UNIT_SET_STR-BUKRS sy-vline
WA_RESC_SETTL_UNIT_SET_STR-SWENR sy-vline
WA_RESC_SETTL_UNIT_SET_STR-SNKSL sy-vline
WA_RESC_SETTL_UNIT_SET_STR-SEMPSL sy-vline
WA_RESC_SETTL_UNIT_SET_STR-OBJNR sy-vline
WA_RESC_SETTL_UNIT_SET_STR-IMKEY sy-vline
WA_RESC_SETTL_UNIT_SET_STR-CREATIONTYPE sy-vline
WA_RESC_SETTL_UNIT_SET_STR-RERF sy-vline
WA_RESC_SETTL_UNIT_SET_STR-DERF sy-vline
WA_RESC_SETTL_UNIT_SET_STR-TERF sy-vline
WA_RESC_SETTL_UNIT_SET_STR-REHER sy-vline
WA_RESC_SETTL_UNIT_SET_STR-RBEAR sy-vline
WA_RESC_SETTL_UNIT_SET_STR-DBEAR sy-vline
WA_RESC_SETTL_UNIT_SET_STR-TBEAR sy-vline
WA_RESC_SETTL_UNIT_SET_STR-RBHER sy-vline
WA_RESC_SETTL_UNIT_SET_STR-RESPONSIBLE sy-vline
WA_RESC_SETTL_UNIT_SET_STR-USEREXCLUSIVE sy-vline
WA_RESC_SETTL_UNIT_SET_STR-AUTHGRP sy-vline
WA_RESC_SETTL_UNIT_SET_STR-VALIDFROM sy-vline
WA_RESC_SETTL_UNIT_SET_STR-VALIDTO sy-vline
WA_RESC_SETTL_UNIT_SET_STR-SUTYPE sy-vline
WA_RESC_SETTL_UNIT_SET_STR-XSU sy-vline
WA_RESC_SETTL_UNIT_SET_STR-TENANCYLAW sy-vline
WA_RESC_SETTL_UNIT_SET_STR-HASCOSTOBJECT sy-vline
WA_RESC_SETTL_UNIT_SET_STR-NOTAXCORR sy-vline
WA_RESC_SETTL_UNIT_SET_STR-EXCHANGETYPE sy-vline
WA_RESC_SETTL_UNIT_SET_STR-SETTLADVPAY sy-vline
WA_RESC_SETTL_UNIT_SET_STR-PERHEATING sy-vline
WA_RESC_SETTL_UNIT_SET_STR-PERHOTWATER sy-vline
WA_RESC_SETTL_UNIT_SET_STR-MSUCROSSOVERCC sy-vline
WA_RESC_SETTL_UNIT_SET_STR-CORRSU sy-vline
WA_RESC_SETTL_UNIT_SET_STR-CORRINTRENO sy-vline
WA_RESC_SETTL_UNIT_SET_STR-CORRVALIDFROM sy-vline
WA_RESC_SETTL_UNIT_SET_STR-CORRVALIDTO sy-vline
WA_RESC_SETTL_UNIT_SET_STR-SUEXTFORSCS sy-vline
WA_RESC_SETTL_UNIT_SET_STR-BUTXT sy-vline
WA_RESC_SETTL_UNIT_SET_STR-XWETEXT sy-vline
WA_RESC_SETTL_UNIT_SET_STR-XSCKEY sy-vline
WA_RESC_SETTL_UNIT_SET_STR-SETTLVARIANT sy-vline
WA_RESC_SETTL_UNIT_SET_STR-PFROM sy-vline
WA_RESC_SETTL_UNIT_SET_STR-PTO sy-vline
WA_RESC_SETTL_UNIT_SET_STR-PROCESSID sy-vline
WA_RESC_SETTL_UNIT_SET_STR-PROCESSEXTID sy-vline
WA_RESC_SETTL_UNIT_SET_STR-XSTATUS sy-vline
WA_RESC_SETTL_UNIT_SET_STR-VALIDITY sy-vline
WA_RESC_SETTL_UNIT_SET_STR-XAUTHGRP sy-vline
WA_RESC_SETTL_UNIT_SET_STR-GSBER sy-vline
WA_RESC_SETTL_UNIT_SET_STR-PRCTR sy-vline
WA_RESC_SETTL_UNIT_SET_STR-COST_INDICATOR sy-vline
WA_RESC_SETTL_UNIT_SET_STR-IS_APPORTIONABLE sy-vline
WA_RESC_SETTL_UNIT_SET_STR-ONLY_COMMERCIAL sy-vline
WA_RESC_SETTL_UNIT_SET_STR-USE_HEATDAYS sy-vline
WA_RESC_SETTL_UNIT_SET_STR-DIRECTCOSTID sy-vline
WA_RESC_SETTL_UNIT_SET_STR-CREDITGLACCSYMB sy-vline
WA_RESC_SETTL_UNIT_SET_STR-SCKEYPROCIND sy-vline
WA_RESC_SETTL_UNIT_SET_STR-SCKEYGRP sy-vline
WA_RESC_SETTL_UNIT_SET_STR-XSCKEYGRP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.