ABAP Select data from SAP table RESC_CNPART_DETAIL_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RESC_CNPART_DETAIL_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RESC_CNPART_DETAIL_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RESC_CNPART_DETAIL_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RESC_CNPART_DETAIL_S TYPE STANDARD TABLE OF RESC_CNPART_DETAIL_S,
      WA_RESC_CNPART_DETAIL_S TYPE RESC_CNPART_DETAIL_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RESC_CNPART_DETAIL_S> TYPE RESC_CNPART_DETAIL_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RESC_CNPART_DETAIL_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RESC_CNPART_DETAIL_S
  INTO TABLE IT_RESC_CNPART_DETAIL_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RESC_CNPART_DETAIL_S
*  INTO TABLE @DATA(IT_RESC_CNPART_DETAIL_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RESC_CNPART_DETAIL_S INDEX 1 INTO DATA(WA_RESC_CNPART_DETAIL_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RESC_CNPART_DETAIL_S ASSIGNING <RESC_CNPART_DETAIL_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RESC_CNPART_DETAIL_S>-OBJGUID = 1.
<RESC_CNPART_DETAIL_S>-SCS_SU_GUID = 1.
<RESC_CNPART_DETAIL_S>-MANDT = 1.
<RESC_CNPART_DETAIL_S>-SU_OBJNR = 1.
<RESC_CNPART_DETAIL_S>-CN_OBJNR = 1.
ENDLOOP.

LOOP AT IT_RESC_CNPART_DETAIL_S INTO WA_RESC_CNPART_DETAIL_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RESC_CNPART_DETAIL_S-RO_OBJNR, sy-vline,
WA_RESC_CNPART_DETAIL_S-VALIDTO, sy-vline,
WA_RESC_CNPART_DETAIL_S-VALIDFROM, sy-vline,
WA_RESC_CNPART_DETAIL_S-PARTTYPE, sy-vline,
WA_RESC_CNPART_DETAIL_S-PTENANT, sy-vline,
WA_RESC_CNPART_DETAIL_S-CONDTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RESC_CNPART_DETAIL_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RESC_CNPART_DETAIL_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RESC_CNPART_DETAIL_S INTO WA_RESC_CNPART_DETAIL_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit REDAT, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RESC_CNPART_DETAIL_S-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_CNPART_DETAIL_S-VALIDTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CONDTYPE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RESC_CNPART_DETAIL_S-CONDTYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_CNPART_DETAIL_S-CONDTYPE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SWENR, internal->external for field SWENR CALL FUNCTION 'CONVERSION_EXIT_SWENR_OUTPUT' EXPORTING input = WA_RESC_CNPART_DETAIL_S-SWENR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_CNPART_DETAIL_S-SWENR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SNKSL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RESC_CNPART_DETAIL_S-SNKSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_CNPART_DETAIL_S-SNKSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SEMPSL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RESC_CNPART_DETAIL_S-SEMPSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RESC_CNPART_DETAIL_S-SEMPSL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RESC_CNPART_DETAIL_S_STR,
OBJGUID TYPE STRING,
SCS_SU_GUID TYPE STRING,
MANDT TYPE STRING,
SU_OBJNR TYPE STRING,
CN_OBJNR TYPE STRING,
RO_OBJNR TYPE STRING,
VALIDTO TYPE STRING,
VALIDFROM TYPE STRING,
PARTTYPE TYPE STRING,
PTENANT TYPE STRING,
CONDTYPE TYPE STRING,
CONDGUID TYPE STRING,
CONDVALIDFROM TYPE STRING,
CURRENCY TYPE STRING,
MAXCOSTSU TYPE STRING,
BASE TYPE STRING,
BASEAMOUNT TYPE STRING,
BASEDATE TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
IS_USED_BY_SETTL TYPE STRING,
IS_CHANGEABLE TYPE STRING,
WAS_GENERATE TYPE STRING,
WAS_CHANGED TYPE STRING,
SETTL_GUID TYPE STRING,
BUKRS TYPE STRING,
SWENR TYPE STRING,
SNKSL TYPE STRING,
SEMPSL TYPE STRING,
XSCKEY TYPE STRING,
XSSCKEY TYPE STRING,
XSU TYPE STRING,
XTEXTCONDL TYPE STRING,
XTEXTCONDM TYPE STRING,
XPARTTYPE TYPE STRING,
XBASE TYPE STRING,
XGENERATEINFO TYPE STRING,
XPARTICIPTYPE TYPE STRING,
XSBASE TYPE STRING,END OF T_EKKO_STR. DATA: WA_RESC_CNPART_DETAIL_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RESC_CNPART_DETAIL_S_STR-OBJGUID sy-vline
WA_RESC_CNPART_DETAIL_S_STR-SCS_SU_GUID sy-vline
WA_RESC_CNPART_DETAIL_S_STR-MANDT sy-vline
WA_RESC_CNPART_DETAIL_S_STR-SU_OBJNR sy-vline
WA_RESC_CNPART_DETAIL_S_STR-CN_OBJNR sy-vline
WA_RESC_CNPART_DETAIL_S_STR-RO_OBJNR sy-vline
WA_RESC_CNPART_DETAIL_S_STR-VALIDTO sy-vline
WA_RESC_CNPART_DETAIL_S_STR-VALIDFROM sy-vline
WA_RESC_CNPART_DETAIL_S_STR-PARTTYPE sy-vline
WA_RESC_CNPART_DETAIL_S_STR-PTENANT sy-vline
WA_RESC_CNPART_DETAIL_S_STR-CONDTYPE sy-vline
WA_RESC_CNPART_DETAIL_S_STR-CONDGUID sy-vline
WA_RESC_CNPART_DETAIL_S_STR-CONDVALIDFROM sy-vline
WA_RESC_CNPART_DETAIL_S_STR-CURRENCY sy-vline
WA_RESC_CNPART_DETAIL_S_STR-MAXCOSTSU sy-vline
WA_RESC_CNPART_DETAIL_S_STR-BASE sy-vline
WA_RESC_CNPART_DETAIL_S_STR-BASEAMOUNT sy-vline
WA_RESC_CNPART_DETAIL_S_STR-BASEDATE sy-vline
WA_RESC_CNPART_DETAIL_S_STR-RERF sy-vline
WA_RESC_CNPART_DETAIL_S_STR-DERF sy-vline
WA_RESC_CNPART_DETAIL_S_STR-TERF sy-vline
WA_RESC_CNPART_DETAIL_S_STR-REHER sy-vline
WA_RESC_CNPART_DETAIL_S_STR-RBEAR sy-vline
WA_RESC_CNPART_DETAIL_S_STR-DBEAR sy-vline
WA_RESC_CNPART_DETAIL_S_STR-TBEAR sy-vline
WA_RESC_CNPART_DETAIL_S_STR-RBHER sy-vline
WA_RESC_CNPART_DETAIL_S_STR-IS_USED_BY_SETTL sy-vline
WA_RESC_CNPART_DETAIL_S_STR-IS_CHANGEABLE sy-vline
WA_RESC_CNPART_DETAIL_S_STR-WAS_GENERATE sy-vline
WA_RESC_CNPART_DETAIL_S_STR-WAS_CHANGED sy-vline
WA_RESC_CNPART_DETAIL_S_STR-SETTL_GUID sy-vline
WA_RESC_CNPART_DETAIL_S_STR-BUKRS sy-vline
WA_RESC_CNPART_DETAIL_S_STR-SWENR sy-vline
WA_RESC_CNPART_DETAIL_S_STR-SNKSL sy-vline
WA_RESC_CNPART_DETAIL_S_STR-SEMPSL sy-vline
WA_RESC_CNPART_DETAIL_S_STR-XSCKEY sy-vline
WA_RESC_CNPART_DETAIL_S_STR-XSSCKEY sy-vline
WA_RESC_CNPART_DETAIL_S_STR-XSU sy-vline
WA_RESC_CNPART_DETAIL_S_STR-XTEXTCONDL sy-vline
WA_RESC_CNPART_DETAIL_S_STR-XTEXTCONDM sy-vline
WA_RESC_CNPART_DETAIL_S_STR-XPARTTYPE sy-vline
WA_RESC_CNPART_DETAIL_S_STR-XBASE sy-vline
WA_RESC_CNPART_DETAIL_S_STR-XGENERATEINFO sy-vline
WA_RESC_CNPART_DETAIL_S_STR-XPARTICIPTYPE sy-vline
WA_RESC_CNPART_DETAIL_S_STR-XSBASE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.