ABAP Select data from SAP table REPRC_FLOW_TYPES_X into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP REPRC_FLOW_TYPES_X table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to REPRC_FLOW_TYPES_X. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the REPRC_FLOW_TYPES_X table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_REPRC_FLOW_TYPES_X TYPE STANDARD TABLE OF REPRC_FLOW_TYPES_X,
      WA_REPRC_FLOW_TYPES_X TYPE REPRC_FLOW_TYPES_X,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <REPRC_FLOW_TYPES_X> TYPE REPRC_FLOW_TYPES_X.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_REPRC_FLOW_TYPES_X.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM REPRC_FLOW_TYPES_X
  INTO TABLE IT_REPRC_FLOW_TYPES_X.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM REPRC_FLOW_TYPES_X
*  INTO TABLE @DATA(IT_REPRC_FLOW_TYPES_X2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_REPRC_FLOW_TYPES_X INDEX 1 INTO DATA(WA_REPRC_FLOW_TYPES_X2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_REPRC_FLOW_TYPES_X ASSIGNING <REPRC_FLOW_TYPES_X>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<REPRC_FLOW_TYPES_X>-MANDT = 1.
<REPRC_FLOW_TYPES_X>-RANTYP = 1.
<REPRC_FLOW_TYPES_X>-SBEWART = 1.
<REPRC_FLOW_TYPES_X>-SBEWAGRP = 1.
<REPRC_FLOW_TYPES_X>-SBEWZITI = 1.
ENDLOOP.

LOOP AT IT_REPRC_FLOW_TYPES_X INTO WA_REPRC_FLOW_TYPES_X.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_REPRC_FLOW_TYPES_X-SSOLHAB, sy-vline,
WA_REPRC_FLOW_TYPES_X-JZINSBAS, sy-vline,
WA_REPRC_FLOW_TYPES_X-JZINSZPT, sy-vline,
WA_REPRC_FLOW_TYPES_X-JRESALD, sy-vline,
WA_REPRC_FLOW_TYPES_X-XBUCHK, sy-vline,
WA_REPRC_FLOW_TYPES_X-JBUCKZ, sy-vline.
ENDLOOP. *Add any further fields from structure WA_REPRC_FLOW_TYPES_X you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_REPRC_FLOW_TYPES_X TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_REPRC_FLOW_TYPES_X INTO WA_REPRC_FLOW_TYPES_X. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SSPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_REPRC_FLOW_TYPES_X-SSPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REPRC_FLOW_TYPES_X-SSPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_REPRC_FLOW_TYPES_X_STR,
MANDT TYPE STRING,
RANTYP TYPE STRING,
SBEWART TYPE STRING,
SBEWAGRP TYPE STRING,
SBEWZITI TYPE STRING,
SSOLHAB TYPE STRING,
JZINSBAS TYPE STRING,
JZINSZPT TYPE STRING,
JRESALD TYPE STRING,
XBUCHK TYPE STRING,
JBUCKZ TYPE STRING,
JFDBUC TYPE STRING,
JEFFZI TYPE STRING,
SABGRENZ TYPE STRING,
SEFFZIVZ TYPE STRING,
JSTOCK TYPE STRING,
SZEGEN TYPE STRING,
JZIABBA TYPE STRING,
SBERFIMA TYPE STRING,
SFIBU TYPE STRING,
SBUST TYPE STRING,
SVORGKZ TYPE STRING,
SAKTPAS TYPE STRING,
JVGLEFFZ TYPE STRING,
JEFFZI2 TYPE STRING,
SEINBEHALT TYPE STRING,
SWPTERM TYPE STRING,
SABGV TYPE STRING,
SZADRI TYPE STRING,
SPAYRQ TYPE STRING,
SPRSNG TYPE STRING,
SNODUNN TYPE STRING,
SSIGN TYPE STRING,
SPAYRQ_LO TYPE STRING,
SPRSNG_LO TYPE STRING,
SNODUN_INT TYPE STRING,
XHIDE_SM TYPE STRING,
VORGTYP TYPE STRING,
VEDEFFZ TYPE STRING,
VJAHREFFZ TYPE STRING,
CLI_RELEVANT TYPE STRING,
CONTAB_RELEVANT TYPE STRING,
SSPRAS TYPE STRING,
XBEWART TYPE STRING,END OF T_EKKO_STR. DATA: WA_REPRC_FLOW_TYPES_X_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_REPRC_FLOW_TYPES_X_STR-MANDT sy-vline
WA_REPRC_FLOW_TYPES_X_STR-RANTYP sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SBEWART sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SBEWAGRP sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SBEWZITI sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SSOLHAB sy-vline
WA_REPRC_FLOW_TYPES_X_STR-JZINSBAS sy-vline
WA_REPRC_FLOW_TYPES_X_STR-JZINSZPT sy-vline
WA_REPRC_FLOW_TYPES_X_STR-JRESALD sy-vline
WA_REPRC_FLOW_TYPES_X_STR-XBUCHK sy-vline
WA_REPRC_FLOW_TYPES_X_STR-JBUCKZ sy-vline
WA_REPRC_FLOW_TYPES_X_STR-JFDBUC sy-vline
WA_REPRC_FLOW_TYPES_X_STR-JEFFZI sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SABGRENZ sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SEFFZIVZ sy-vline
WA_REPRC_FLOW_TYPES_X_STR-JSTOCK sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SZEGEN sy-vline
WA_REPRC_FLOW_TYPES_X_STR-JZIABBA sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SBERFIMA sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SFIBU sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SBUST sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SVORGKZ sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SAKTPAS sy-vline
WA_REPRC_FLOW_TYPES_X_STR-JVGLEFFZ sy-vline
WA_REPRC_FLOW_TYPES_X_STR-JEFFZI2 sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SEINBEHALT sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SWPTERM sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SABGV sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SZADRI sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SPAYRQ sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SPRSNG sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SNODUNN sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SSIGN sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SPAYRQ_LO sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SPRSNG_LO sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SNODUN_INT sy-vline
WA_REPRC_FLOW_TYPES_X_STR-XHIDE_SM sy-vline
WA_REPRC_FLOW_TYPES_X_STR-VORGTYP sy-vline
WA_REPRC_FLOW_TYPES_X_STR-VEDEFFZ sy-vline
WA_REPRC_FLOW_TYPES_X_STR-VJAHREFFZ sy-vline
WA_REPRC_FLOW_TYPES_X_STR-CLI_RELEVANT sy-vline
WA_REPRC_FLOW_TYPES_X_STR-CONTAB_RELEVANT sy-vline
WA_REPRC_FLOW_TYPES_X_STR-SSPRAS sy-vline
WA_REPRC_FLOW_TYPES_X_STR-XBEWART sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.