ABAP Select data from SAP table RELM_PL_USAGE_L1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RELM_PL_USAGE_L1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RELM_PL_USAGE_L1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RELM_PL_USAGE_L1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RELM_PL_USAGE_L1 TYPE STANDARD TABLE OF RELM_PL_USAGE_L1,
      WA_RELM_PL_USAGE_L1 TYPE RELM_PL_USAGE_L1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RELM_PL_USAGE_L1> TYPE RELM_PL_USAGE_L1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RELM_PL_USAGE_L1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RELM_PL_USAGE_L1
  INTO TABLE IT_RELM_PL_USAGE_L1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RELM_PL_USAGE_L1
*  INTO TABLE @DATA(IT_RELM_PL_USAGE_L12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RELM_PL_USAGE_L1 INDEX 1 INTO DATA(WA_RELM_PL_USAGE_L12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RELM_PL_USAGE_L1 ASSIGNING <RELM_PL_USAGE_L1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RELM_PL_USAGE_L1>-MANDT = 1.
<RELM_PL_USAGE_L1>-INTRENO = 1.
<RELM_PL_USAGE_L1>-PLUSSEQNO = 1.
<RELM_PL_USAGE_L1>-OBJRELGUID = 1.
<RELM_PL_USAGE_L1>-PLUSIND = 1.
ENDLOOP.

LOOP AT IT_RELM_PL_USAGE_L1 INTO WA_RELM_PL_USAGE_L1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RELM_PL_USAGE_L1-PLUSTYPE, sy-vline,
WA_RELM_PL_USAGE_L1-PLUSSUBTYPE, sy-vline,
WA_RELM_PL_USAGE_L1-PLUSMEASVALUE, sy-vline,
WA_RELM_PL_USAGE_L1-PLUSMEASUNIT, sy-vline,
WA_RELM_PL_USAGE_L1-PLUSISOPNEC, sy-vline,
WA_RELM_PL_USAGE_L1-VALIDFROM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RELM_PL_USAGE_L1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RELM_PL_USAGE_L1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RELM_PL_USAGE_L1 INTO WA_RELM_PL_USAGE_L1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field PLUSMEASUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RELM_PL_USAGE_L1-PLUSMEASUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RELM_PL_USAGE_L1-PLUSMEASUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RELM_PL_USAGE_L1-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RELM_PL_USAGE_L1-VALIDTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNERBP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RELM_PL_USAGE_L1-PARTNERBP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RELM_PL_USAGE_L1-PARTNERBP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field VALIDTOBP CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RELM_PL_USAGE_L1-VALIDTOBP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RELM_PL_USAGE_L1-VALIDTOBP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RELM_PL_USAGE_L1_STR,
MANDT TYPE STRING,
INTRENO TYPE STRING,
PLUSSEQNO TYPE STRING,
OBJRELGUID TYPE STRING,
PLUSIND TYPE STRING,
PLUSTYPE TYPE STRING,
PLUSSUBTYPE TYPE STRING,
PLUSMEASVALUE TYPE STRING,
PLUSMEASUNIT TYPE STRING,
PLUSISOPNEC TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
PLUSREALDATE TYPE STRING,
XPLUSCOMMENT TYPE STRING,
XPLUSTYPE TYPE STRING,
XPLUSSUBTYPE TYPE STRING,
XPLUSIND TYPE STRING,
PARTNERBP TYPE STRING,
ROLEBP TYPE STRING,
SUBROLEBP TYPE STRING,
VALIDFROMBP TYPE STRING,
VALIDTOBP TYPE STRING,
ROLECATEBP TYPE STRING,
XROLEBP TYPE STRING,
XSUBROLEBP TYPE STRING,
XPARTNERBP TYPE STRING,
XNAMEBP TYPE STRING,
XADDRESSBP TYPE STRING,
ICON_DETAIL TYPE STRING,
ICON_PLUSIND TYPE STRING,END OF T_EKKO_STR. DATA: WA_RELM_PL_USAGE_L1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RELM_PL_USAGE_L1_STR-MANDT sy-vline
WA_RELM_PL_USAGE_L1_STR-INTRENO sy-vline
WA_RELM_PL_USAGE_L1_STR-PLUSSEQNO sy-vline
WA_RELM_PL_USAGE_L1_STR-OBJRELGUID sy-vline
WA_RELM_PL_USAGE_L1_STR-PLUSIND sy-vline
WA_RELM_PL_USAGE_L1_STR-PLUSTYPE sy-vline
WA_RELM_PL_USAGE_L1_STR-PLUSSUBTYPE sy-vline
WA_RELM_PL_USAGE_L1_STR-PLUSMEASVALUE sy-vline
WA_RELM_PL_USAGE_L1_STR-PLUSMEASUNIT sy-vline
WA_RELM_PL_USAGE_L1_STR-PLUSISOPNEC sy-vline
WA_RELM_PL_USAGE_L1_STR-VALIDFROM sy-vline
WA_RELM_PL_USAGE_L1_STR-VALIDTO sy-vline
WA_RELM_PL_USAGE_L1_STR-PLUSREALDATE sy-vline
WA_RELM_PL_USAGE_L1_STR-XPLUSCOMMENT sy-vline
WA_RELM_PL_USAGE_L1_STR-XPLUSTYPE sy-vline
WA_RELM_PL_USAGE_L1_STR-XPLUSSUBTYPE sy-vline
WA_RELM_PL_USAGE_L1_STR-XPLUSIND sy-vline
WA_RELM_PL_USAGE_L1_STR-PARTNERBP sy-vline
WA_RELM_PL_USAGE_L1_STR-ROLEBP sy-vline
WA_RELM_PL_USAGE_L1_STR-SUBROLEBP sy-vline
WA_RELM_PL_USAGE_L1_STR-VALIDFROMBP sy-vline
WA_RELM_PL_USAGE_L1_STR-VALIDTOBP sy-vline
WA_RELM_PL_USAGE_L1_STR-ROLECATEBP sy-vline
WA_RELM_PL_USAGE_L1_STR-XROLEBP sy-vline
WA_RELM_PL_USAGE_L1_STR-XSUBROLEBP sy-vline
WA_RELM_PL_USAGE_L1_STR-XPARTNERBP sy-vline
WA_RELM_PL_USAGE_L1_STR-XNAMEBP sy-vline
WA_RELM_PL_USAGE_L1_STR-XADDRESSBP sy-vline
WA_RELM_PL_USAGE_L1_STR-ICON_DETAIL sy-vline
WA_RELM_PL_USAGE_L1_STR-ICON_PLUSIND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.