ABAP Select data from SAP table RELM_LR_RE_REGISTER_X into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RELM_LR_RE_REGISTER_X table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RELM_LR_RE_REGISTER_X. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RELM_LR_RE_REGISTER_X table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RELM_LR_RE_REGISTER_X TYPE STANDARD TABLE OF RELM_LR_RE_REGISTER_X,
      WA_RELM_LR_RE_REGISTER_X TYPE RELM_LR_RE_REGISTER_X,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RELM_LR_RE_REGISTER_X> TYPE RELM_LR_RE_REGISTER_X.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RELM_LR_RE_REGISTER_X.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RELM_LR_RE_REGISTER_X
  INTO TABLE IT_RELM_LR_RE_REGISTER_X.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RELM_LR_RE_REGISTER_X
*  INTO TABLE @DATA(IT_RELM_LR_RE_REGISTER_X2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RELM_LR_RE_REGISTER_X INDEX 1 INTO DATA(WA_RELM_LR_RE_REGISTER_X2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RELM_LR_RE_REGISTER_X ASSIGNING <RELM_LR_RE_REGISTER_X>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RELM_LR_RE_REGISTER_X>-MANDT = 1.
<RELM_LR_RE_REGISTER_X>-INTRENO = 1.
<RELM_LR_RE_REGISTER_X>-LRREGNO = 1.
<RELM_LR_RE_REGISTER_X>-LRREGSUBNO = 1.
<RELM_LR_RE_REGISTER_X>-COOWNERNUM = 1.
ENDLOOP.

LOOP AT IT_RELM_LR_RE_REGISTER_X INTO WA_RELM_LR_RE_REGISTER_X.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RELM_LR_RE_REGISTER_X-COOWNERDENOM, sy-vline,
WA_RELM_LR_RE_REGISTER_X-RPRGNO, sy-vline,
WA_RELM_LR_RE_REGISTER_X-LRMEASVALUE, sy-vline,
WA_RELM_LR_RE_REGISTER_X-MEASUNIT, sy-vline,
WA_RELM_LR_RE_REGISTER_X-APPLICATIONDATE, sy-vline,
WA_RELM_LR_RE_REGISTER_X-ENTRYDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RELM_LR_RE_REGISTER_X you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RELM_LR_RE_REGISTER_X TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RELM_LR_RE_REGISTER_X INTO WA_RELM_LR_RE_REGISTER_X. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit LRREG, internal->external for field LRREGNO CALL FUNCTION 'CONVERSION_EXIT_LRREG_OUTPUT' EXPORTING input = WA_RELM_LR_RE_REGISTER_X-LRREGNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RELM_LR_RE_REGISTER_X-LRREGNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RELM_LR_RE_REGISTER_X-MEASUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RELM_LR_RE_REGISTER_X-MEASUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field CANCELDATE CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RELM_LR_RE_REGISTER_X-CANCELDATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RELM_LR_RE_REGISTER_X-CANCELDATE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LRPGN, internal->external for field HERITLRPAGENO CALL FUNCTION 'CONVERSION_EXIT_LRPGN_OUTPUT' EXPORTING input = WA_RELM_LR_RE_REGISTER_X-HERITLRPAGENO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RELM_LR_RE_REGISTER_X-HERITLRPAGENO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LRSEC, internal->external for field HERITSEC2NO CALL FUNCTION 'CONVERSION_EXIT_LRSEC_OUTPUT' EXPORTING input = WA_RELM_LR_RE_REGISTER_X-HERITSEC2NO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RELM_LR_RE_REGISTER_X-HERITSEC2NO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field HERITOWNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RELM_LR_RE_REGISTER_X-HERITOWNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RELM_LR_RE_REGISTER_X-HERITOWNER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RELM_LR_RE_REGISTER_X_STR,
MANDT TYPE STRING,
INTRENO TYPE STRING,
LRREGNO TYPE STRING,
LRREGSUBNO TYPE STRING,
COOWNERNUM TYPE STRING,
COOWNERDENOM TYPE STRING,
RPRGNO TYPE STRING,
LRMEASVALUE TYPE STRING,
MEASUNIT TYPE STRING,
APPLICATIONDATE TYPE STRING,
ENTRYDATE TYPE STRING,
APPROVALDATE TYPE STRING,
CANCELDATE TYPE STRING,
XCOMMENT TYPE STRING,
HERITLRDISTRICT TYPE STRING,
HERITLRVOLUMENO TYPE STRING,
HERITLRPAGENO TYPE STRING,
HERITSEC2NO TYPE STRING,
HERITOWNER TYPE STRING,
HERITFIXTERMDATE TYPE STRING,
HERITTERM TYPE STRING,
ISDOMTENENTRY TYPE STRING,
DOMTENENTRYDATE TYPE STRING,
ENCUMBRANCETYPE TYPE STRING,
PLEXTIDENTKEY TYPE STRING,
PLOBJNR TYPE STRING,
PLEXTIDENTKEYL TYPE STRING,
HASNOTE TYPE STRING,
XADDITIONSTOLR TYPE STRING,
XOLDRGENTRIES TYPE STRING,
XDTADDITIONS TYPE STRING,
XENCUMBRANCETYPE TYPE STRING,
HERITOWNERROLE TYPE STRING,
HERITOWNERSUBROLE TYPE STRING,
HERITOWNERXPARTNER TYPE STRING,
HERITOWNERXNAME TYPE STRING,
HERITOWNERXADDRESS TYPE STRING,
XCOOWNER TYPE STRING,
PLIDENTKEY TYPE STRING,
PLEXISTS TYPE STRING,
XLOCHIER TYPE STRING,END OF T_EKKO_STR. DATA: WA_RELM_LR_RE_REGISTER_X_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-MANDT sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-INTRENO sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-LRREGNO sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-LRREGSUBNO sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-COOWNERNUM sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-COOWNERDENOM sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-RPRGNO sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-LRMEASVALUE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-MEASUNIT sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-APPLICATIONDATE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-ENTRYDATE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-APPROVALDATE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-CANCELDATE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-XCOMMENT sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITLRDISTRICT sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITLRVOLUMENO sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITLRPAGENO sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITSEC2NO sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITOWNER sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITFIXTERMDATE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITTERM sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-ISDOMTENENTRY sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-DOMTENENTRYDATE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-ENCUMBRANCETYPE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-PLEXTIDENTKEY sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-PLOBJNR sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-PLEXTIDENTKEYL sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HASNOTE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-XADDITIONSTOLR sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-XOLDRGENTRIES sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-XDTADDITIONS sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-XENCUMBRANCETYPE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITOWNERROLE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITOWNERSUBROLE sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITOWNERXPARTNER sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITOWNERXNAME sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-HERITOWNERXADDRESS sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-XCOOWNER sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-PLIDENTKEY sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-PLEXISTS sy-vline
WA_RELM_LR_RE_REGISTER_X_STR-XLOCHIER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.