ABAP Select data from SAP table REG42_ZW_INPUT_FLAG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP REG42_ZW_INPUT_FLAG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to REG42_ZW_INPUT_FLAG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the REG42_ZW_INPUT_FLAG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_REG42_ZW_INPUT_FLAG TYPE STANDARD TABLE OF REG42_ZW_INPUT_FLAG,
      WA_REG42_ZW_INPUT_FLAG TYPE REG42_ZW_INPUT_FLAG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <REG42_ZW_INPUT_FLAG> TYPE REG42_ZW_INPUT_FLAG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_REG42_ZW_INPUT_FLAG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM REG42_ZW_INPUT_FLAG
  INTO TABLE IT_REG42_ZW_INPUT_FLAG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM REG42_ZW_INPUT_FLAG
*  INTO TABLE @DATA(IT_REG42_ZW_INPUT_FLAG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_REG42_ZW_INPUT_FLAG INDEX 1 INTO DATA(WA_REG42_ZW_INPUT_FLAG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_REG42_ZW_INPUT_FLAG ASSIGNING <REG42_ZW_INPUT_FLAG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<REG42_ZW_INPUT_FLAG>-EQUNR = 1.
<REG42_ZW_INPUT_FLAG>-BIS = 1.
<REG42_ZW_INPUT_FLAG>-AB = 1.
<REG42_ZW_INPUT_FLAG>-GERAET = 1.
<REG42_ZW_INPUT_FLAG>-MATNR = 1.
ENDLOOP.

LOOP AT IT_REG42_ZW_INPUT_FLAG INTO WA_REG42_ZW_INPUT_FLAG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_REG42_ZW_INPUT_FLAG-ZWNUMMER, sy-vline,
WA_REG42_ZW_INPUT_FLAG-KENNZIFF, sy-vline,
WA_REG42_ZW_INPUT_FLAG-KZMESSW, sy-vline,
WA_REG42_ZW_INPUT_FLAG-STEUERGRP, sy-vline,
WA_REG42_ZW_INPUT_FLAG-ZWKENN, sy-vline,
WA_REG42_ZW_INPUT_FLAG-ZWART, sy-vline.
ENDLOOP. *Add any further fields from structure WA_REG42_ZW_INPUT_FLAG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_REG42_ZW_INPUT_FLAG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_REG42_ZW_INPUT_FLAG INTO WA_REG42_ZW_INPUT_FLAG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REG42_ZW_INPUT_FLAG-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG42_ZW_INPUT_FLAG-EQUNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GERNR, internal->external for field GERAET CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_REG42_ZW_INPUT_FLAG-GERAET IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG42_ZW_INPUT_FLAG-GERAET.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_REG42_ZW_INPUT_FLAG-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG42_ZW_INPUT_FLAG-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_REG42_ZW_INPUT_FLAG_STR,
EQUNR TYPE STRING,
BIS TYPE STRING,
AB TYPE STRING,
GERAET TYPE STRING,
MATNR TYPE STRING,
ZWNUMMER TYPE STRING,
KENNZIFF TYPE STRING,
KZMESSW TYPE STRING,
STEUERGRP TYPE STRING,
ZWKENN TYPE STRING,
ZWART TYPE STRING,
STANZVOR TYPE STRING,
STANZNAC TYPE STRING,
ANZERG TYPE STRING,
UEBERVER TYPE STRING,
NABLESEN TYPE STRING,
ZWFAKT TYPE STRING,
PRUEFKL TYPE STRING,
TEMP_AREA TYPE STRING,
PR_AREA_AI TYPE STRING,
CALOR_AREA TYPE STRING,
HOEKORR TYPE STRING,
THGBER TYPE STRING,
KZAHLE TYPE STRING,
KZAHLT TYPE STRING,
GAS_PRS_AR TYPE STRING,
CRGPRESS TYPE STRING,
MEINS TYPE STRING,
GEWKEY TYPE STRING,
MASSBILLC6 TYPE STRING,
TOUPERIOD TYPE STRING,
BLIWIRK TYPE STRING,
SPARTYP TYPE STRING,
ZWTYP TYPE STRING,
INTSIZEID TYPE STRING,
ZSPANNS TYPE STRING,
ZSTROMS TYPE STRING,
ZSPANNP TYPE STRING,
ZSTROMP TYPE STRING,
VEE_CODE TYPE STRING,END OF T_EKKO_STR. DATA: WA_REG42_ZW_INPUT_FLAG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-EQUNR sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-BIS sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-AB sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-GERAET sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-MATNR sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-ZWNUMMER sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-KENNZIFF sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-KZMESSW sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-STEUERGRP sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-ZWKENN sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-ZWART sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-STANZVOR sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-STANZNAC sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-ANZERG sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-UEBERVER sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-NABLESEN sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-ZWFAKT sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-PRUEFKL sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-TEMP_AREA sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-PR_AREA_AI sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-CALOR_AREA sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-HOEKORR sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-THGBER sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-KZAHLE sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-KZAHLT sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-GAS_PRS_AR sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-CRGPRESS sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-MEINS sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-GEWKEY sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-MASSBILLC6 sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-TOUPERIOD sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-BLIWIRK sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-SPARTYP sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-ZWTYP sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-INTSIZEID sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-ZSPANNS sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-ZSTROMS sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-ZSPANNP sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-ZSTROMP sy-vline
WA_REG42_ZW_INPUT_FLAG_STR-VEE_CODE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.