ABAP Select data from SAP table REG30_AUTO_ZW_MOD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP REG30_AUTO_ZW_MOD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to REG30_AUTO_ZW_MOD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the REG30_AUTO_ZW_MOD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_REG30_AUTO_ZW_MOD TYPE STANDARD TABLE OF REG30_AUTO_ZW_MOD,
      WA_REG30_AUTO_ZW_MOD TYPE REG30_AUTO_ZW_MOD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <REG30_AUTO_ZW_MOD> TYPE REG30_AUTO_ZW_MOD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_REG30_AUTO_ZW_MOD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM REG30_AUTO_ZW_MOD
  INTO TABLE IT_REG30_AUTO_ZW_MOD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM REG30_AUTO_ZW_MOD
*  INTO TABLE @DATA(IT_REG30_AUTO_ZW_MOD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_REG30_AUTO_ZW_MOD INDEX 1 INTO DATA(WA_REG30_AUTO_ZW_MOD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_REG30_AUTO_ZW_MOD ASSIGNING <REG30_AUTO_ZW_MOD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<REG30_AUTO_ZW_MOD>-ZWNUMMERE = 1.
<REG30_AUTO_ZW_MOD>-ABLSTATE = 1.
<REG30_AUTO_ZW_MOD>-MESSDRCKE = 1.
<REG30_AUTO_ZW_MOD>-ERFASSNACE = 1.
<REG30_AUTO_ZW_MOD>-GERAETE = 1.
ENDLOOP.

LOOP AT IT_REG30_AUTO_ZW_MOD INTO WA_REG30_AUTO_ZW_MOD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_REG30_AUTO_ZW_MOD-EQUNRE, sy-vline,
WA_REG30_AUTO_ZW_MOD-MATNRE, sy-vline,
WA_REG30_AUTO_ZW_MOD-PROGTE, sy-vline,
WA_REG30_AUTO_ZW_MOD-LOGIKZWE, sy-vline,
WA_REG30_AUTO_ZW_MOD-METERDOCE, sy-vline,
WA_REG30_AUTO_ZW_MOD-PERVERBRE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_REG30_AUTO_ZW_MOD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_REG30_AUTO_ZW_MOD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_REG30_AUTO_ZW_MOD INTO WA_REG30_AUTO_ZW_MOD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit GERNR, internal->external for field GERAETE CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_REG30_AUTO_ZW_MOD-GERAETE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG30_AUTO_ZW_MOD-GERAETE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field EQUNRE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REG30_AUTO_ZW_MOD-EQUNRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG30_AUTO_ZW_MOD-EQUNRE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNRE CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_REG30_AUTO_ZW_MOD-MATNRE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG30_AUTO_ZW_MOD-MATNRE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RABZUSE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REG30_AUTO_ZW_MOD-RABZUSE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG30_AUTO_ZW_MOD-RABZUSE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PREISKLAE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REG30_AUTO_ZW_MOD-PREISKLAE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG30_AUTO_ZW_MOD-PREISKLAE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MASSBILLE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_REG30_AUTO_ZW_MOD-MASSBILLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG30_AUTO_ZW_MOD-MASSBILLE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_REG30_AUTO_ZW_MOD-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG30_AUTO_ZW_MOD-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MASSREADE CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_REG30_AUTO_ZW_MOD-MASSREADE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG30_AUTO_ZW_MOD-MASSREADE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LUNIT, internal->external for field MASSBILLC6E CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_REG30_AUTO_ZW_MOD-MASSBILLC6E IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REG30_AUTO_ZW_MOD-MASSBILLC6E.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_REG30_AUTO_ZW_MOD_STR,
ZWNUMMERE TYPE STRING,
ABLSTATE TYPE STRING,
MESSDRCKE TYPE STRING,
ERFASSNACE TYPE STRING,
GERAETE TYPE STRING,
EQUNRE TYPE STRING,
MATNRE TYPE STRING,
PROGTE TYPE STRING,
LOGIKZWE TYPE STRING,
METERDOCE TYPE STRING,
PERVERBRE TYPE STRING,
FIRST_ALLOC TYPE STRING,
KONDIGRE TYPE STRING,
ZWSTANDCE TYPE STRING,
THGVER TYPE STRING,
FESTTEMP TYPE STRING,
ZUSZAHLZWE TYPE STRING,
STEUERGRPE TYPE STRING,
PROFESTE TYPE STRING,
PROPROZE TYPE STRING,
ZEITRAUME TYPE STRING,
RABZUSE TYPE STRING,
ANZERG TYPE STRING,
ZWNABR TYPE STRING,
PREISKLAE TYPE STRING,
TARIFART TYPE STRING,
ANZDAYSOFPERIOD TYPE STRING,
PERVERBR TYPE STRING,
GVERRECH TYPE STRING,
KENNZIFFE TYPE STRING,
ZWZUORD TYPE STRING,
TEMP_AREA TYPE STRING,
PR_AREA_AI TYPE STRING,
CALOR_AREA TYPE STRING,
HOEKORR TYPE STRING,
KZAHLE TYPE STRING,
KZAHLT TYPE STRING,
GAS_PRS_AR TYPE STRING,
CRGPRESS TYPE STRING,
ABRFAKTE TYPE STRING,
NABLESENE TYPE STRING,
MASSBILLE TYPE STRING,
GEWKEYE TYPE STRING,
PRUEFKLE TYPE STRING,
SPARTYPE TYPE STRING,
ZWTYPE TYPE STRING,
BLIWIRKE TYPE STRING,
ZWARTE TYPE STRING,
ZWKENNE TYPE STRING,
THGBERE TYPE STRING,
MEINS TYPE STRING,
INTSIZEIDE TYPE STRING,
MASSREADE TYPE STRING,
KZMESSWE TYPE STRING,
STANZVORE TYPE STRING,
STANZNACE TYPE STRING,
UEBERVERE TYPE STRING,
ZWFAKTE TYPE STRING,
ZSPANNSE TYPE STRING,
ZSTROMSE TYPE STRING,
ZSPANNPE TYPE STRING,
ZSTROMPE TYPE STRING,
MASSBILLC6E TYPE STRING,
TOUPERIODE TYPE STRING,
ZWNSETTLE TYPE STRING,
VEE_CODEE TYPE STRING,
DO_NOT_USE TYPE STRING,END OF T_EKKO_STR. DATA: WA_REG30_AUTO_ZW_MOD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZWNUMMERE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ABLSTATE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-MESSDRCKE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ERFASSNACE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-GERAETE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-EQUNRE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-MATNRE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-PROGTE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-LOGIKZWE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-METERDOCE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-PERVERBRE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-FIRST_ALLOC sy-vline
WA_REG30_AUTO_ZW_MOD_STR-KONDIGRE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZWSTANDCE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-THGVER sy-vline
WA_REG30_AUTO_ZW_MOD_STR-FESTTEMP sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZUSZAHLZWE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-STEUERGRPE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-PROFESTE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-PROPROZE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZEITRAUME sy-vline
WA_REG30_AUTO_ZW_MOD_STR-RABZUSE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ANZERG sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZWNABR sy-vline
WA_REG30_AUTO_ZW_MOD_STR-PREISKLAE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-TARIFART sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ANZDAYSOFPERIOD sy-vline
WA_REG30_AUTO_ZW_MOD_STR-PERVERBR sy-vline
WA_REG30_AUTO_ZW_MOD_STR-GVERRECH sy-vline
WA_REG30_AUTO_ZW_MOD_STR-KENNZIFFE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZWZUORD sy-vline
WA_REG30_AUTO_ZW_MOD_STR-TEMP_AREA sy-vline
WA_REG30_AUTO_ZW_MOD_STR-PR_AREA_AI sy-vline
WA_REG30_AUTO_ZW_MOD_STR-CALOR_AREA sy-vline
WA_REG30_AUTO_ZW_MOD_STR-HOEKORR sy-vline
WA_REG30_AUTO_ZW_MOD_STR-KZAHLE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-KZAHLT sy-vline
WA_REG30_AUTO_ZW_MOD_STR-GAS_PRS_AR sy-vline
WA_REG30_AUTO_ZW_MOD_STR-CRGPRESS sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ABRFAKTE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-NABLESENE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-MASSBILLE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-GEWKEYE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-PRUEFKLE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-SPARTYPE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZWTYPE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-BLIWIRKE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZWARTE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZWKENNE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-THGBERE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-MEINS sy-vline
WA_REG30_AUTO_ZW_MOD_STR-INTSIZEIDE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-MASSREADE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-KZMESSWE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-STANZVORE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-STANZNACE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-UEBERVERE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZWFAKTE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZSPANNSE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZSTROMSE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZSPANNPE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZSTROMPE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-MASSBILLC6E sy-vline
WA_REG30_AUTO_ZW_MOD_STR-TOUPERIODE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-ZWNSETTLE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-VEE_CODEE sy-vline
WA_REG30_AUTO_ZW_MOD_STR-DO_NOT_USE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.