ABAP Select data from SAP table REEXC_STATUS_TRANS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP REEXC_STATUS_TRANS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to REEXC_STATUS_TRANS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the REEXC_STATUS_TRANS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_REEXC_STATUS_TRANS TYPE STANDARD TABLE OF REEXC_STATUS_TRANS,
      WA_REEXC_STATUS_TRANS TYPE REEXC_STATUS_TRANS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <REEXC_STATUS_TRANS> TYPE REEXC_STATUS_TRANS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_REEXC_STATUS_TRANS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM REEXC_STATUS_TRANS
  INTO TABLE IT_REEXC_STATUS_TRANS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM REEXC_STATUS_TRANS
*  INTO TABLE @DATA(IT_REEXC_STATUS_TRANS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_REEXC_STATUS_TRANS INDEX 1 INTO DATA(WA_REEXC_STATUS_TRANS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_REEXC_STATUS_TRANS ASSIGNING <REEXC_STATUS_TRANS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<REEXC_STATUS_TRANS>-VRGNG = 1.
<REEXC_STATUS_TRANS>-VRGSV = 1.
<REEXC_STATUS_TRANS>-ANWST = 1.
<REEXC_STATUS_TRANS>-PRVRG = 1.
<REEXC_STATUS_TRANS>-VRGJV = 1.
ENDLOOP.

LOOP AT IT_REEXC_STATUS_TRANS INTO WA_REEXC_STATUS_TRANS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_REEXC_STATUS_TRANS-VRGCO, sy-vline,
WA_REEXC_STATUS_TRANS-NVVRG, sy-vline,
WA_REEXC_STATUS_TRANS-PERSP, sy-vline,
WA_REEXC_STATUS_TRANS-PSIKZ, sy-vline,
WA_REEXC_STATUS_TRANS-WTKAT, sy-vline,
WA_REEXC_STATUS_TRANS-ACTGRP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_REEXC_STATUS_TRANS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_REEXC_STATUS_TRANS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_REEXC_STATUS_TRANS INTO WA_REEXC_STATUS_TRANS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_REEXC_STATUS_TRANS_STR,
VRGNG TYPE STRING,
VRGSV TYPE STRING,
ANWST TYPE STRING,
PRVRG TYPE STRING,
VRGJV TYPE STRING,
VRGCO TYPE STRING,
NVVRG TYPE STRING,
PERSP TYPE STRING,
PSIKZ TYPE STRING,
WTKAT TYPE STRING,
ACTGRP TYPE STRING,
SUBGRP TYPE STRING,
XCOEP TYPE STRING,
XCOEJ TYPE STRING,
XCOOI TYPE STRING,
XCOSP TYPE STRING,
XCOSS TYPE STRING,
XCOEPL TYPE STRING,
XCOEJL TYPE STRING,
XCOEPR TYPE STRING,
XCOEJR TYPE STRING,
XCOEPT TYPE STRING,
XCOEJT TYPE STRING,
XCOEPB TYPE STRING,
XCOFP TYPE STRING,
XFMGM TYPE STRING,END OF T_EKKO_STR. DATA: WA_REEXC_STATUS_TRANS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_REEXC_STATUS_TRANS_STR-VRGNG sy-vline
WA_REEXC_STATUS_TRANS_STR-VRGSV sy-vline
WA_REEXC_STATUS_TRANS_STR-ANWST sy-vline
WA_REEXC_STATUS_TRANS_STR-PRVRG sy-vline
WA_REEXC_STATUS_TRANS_STR-VRGJV sy-vline
WA_REEXC_STATUS_TRANS_STR-VRGCO sy-vline
WA_REEXC_STATUS_TRANS_STR-NVVRG sy-vline
WA_REEXC_STATUS_TRANS_STR-PERSP sy-vline
WA_REEXC_STATUS_TRANS_STR-PSIKZ sy-vline
WA_REEXC_STATUS_TRANS_STR-WTKAT sy-vline
WA_REEXC_STATUS_TRANS_STR-ACTGRP sy-vline
WA_REEXC_STATUS_TRANS_STR-SUBGRP sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOEP sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOEJ sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOOI sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOSP sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOSS sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOEPL sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOEJL sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOEPR sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOEJR sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOEPT sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOEJT sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOEPB sy-vline
WA_REEXC_STATUS_TRANS_STR-XCOFP sy-vline
WA_REEXC_STATUS_TRANS_STR-XFMGM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.