ABAP Select data from SAP table RECP_SF_DOC_A110 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RECP_SF_DOC_A110 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RECP_SF_DOC_A110. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RECP_SF_DOC_A110 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RECP_SF_DOC_A110 TYPE STANDARD TABLE OF RECP_SF_DOC_A110,
      WA_RECP_SF_DOC_A110 TYPE RECP_SF_DOC_A110,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RECP_SF_DOC_A110> TYPE RECP_SF_DOC_A110.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RECP_SF_DOC_A110.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RECP_SF_DOC_A110
  INTO TABLE IT_RECP_SF_DOC_A110.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RECP_SF_DOC_A110
*  INTO TABLE @DATA(IT_RECP_SF_DOC_A1102).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RECP_SF_DOC_A110 INDEX 1 INTO DATA(WA_RECP_SF_DOC_A1102).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RECP_SF_DOC_A110 ASSIGNING <RECP_SF_DOC_A110>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RECP_SF_DOC_A110>-BUSTYPE = 1.
<RECP_SF_DOC_A110>-BUSKEY = 1.
<RECP_SF_DOC_A110>-XMBUSOBJ = 1.
<RECP_SF_DOC_A110>-BUKRS = 1.
<RECP_SF_DOC_A110>-RESPONSIBLE = 1.
ENDLOOP.

LOOP AT IT_RECP_SF_DOC_A110 INTO WA_RECP_SF_DOC_A110.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RECP_SF_DOC_A110-INTRENO, sy-vline,
WA_RECP_SF_DOC_A110-OBJNR, sy-vline,
WA_RECP_SF_DOC_A110-OBJRELGUID, sy-vline,
WA_RECP_SF_DOC_A110-PARTNER, sy-vline,
WA_RECP_SF_DOC_A110-ROLE, sy-vline,
WA_RECP_SF_DOC_A110-ADDRTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RECP_SF_DOC_A110 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RECP_SF_DOC_A110 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RECP_SF_DOC_A110 INTO WA_RECP_SF_DOC_A110. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PARTNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RECP_SF_DOC_A110-PARTNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_SF_DOC_A110-PARTNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field XMAILORFAXNO CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_RECP_SF_DOC_A110-XMAILORFAXNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_SF_DOC_A110-XMAILORFAXNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_RECP_SF_DOC_A110-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_SF_DOC_A110-LANGU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field SENDER_EMAIL_URI CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_RECP_SF_DOC_A110-SENDER_EMAIL_URI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_SF_DOC_A110-SENDER_EMAIL_URI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AOFUNCTION_SP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RECP_SF_DOC_A110-AOFUNCTION_SP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_SF_DOC_A110-AOFUNCTION_SP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RECP_SF_DOC_A110_STR,
BUSTYPE TYPE STRING,
BUSKEY TYPE STRING,
XMBUSOBJ TYPE STRING,
BUKRS TYPE STRING,
RESPONSIBLE TYPE STRING,
INTRENO TYPE STRING,
OBJNR TYPE STRING,
OBJRELGUID TYPE STRING,
PARTNER TYPE STRING,
ROLE TYPE STRING,
ADDRTYPE TYPE STRING,
XPARTNER TYPE STRING,
PARTN_CAT TYPE STRING,
PARTN_GRP TYPE STRING,
SEARCHTERM1 TYPE STRING,
SEARCHTERM2 TYPE STRING,
COMM_TYPE TYPE STRING,
CPACT TYPE STRING,
FMSEQNO TYPE STRING,
RECIPGRP TYPE STRING,
RECIPCATE TYPE STRING,
RECIPROLE TYPE STRING,
RECIPSUBROLE TYPE STRING,
RECIPFINDHIER TYPE STRING,
FNAME TYPE STRING,
XFNAME TYPE STRING,
FORMTYPE TYPE STRING,
SFNAME TYPE STRING,
TDCOPIESFM TYPE STRING,
TDDEVICETYPE TYPE STRING,
TDDEVICEICON TYPE STRING,
XMAILORFAXNO TYPE STRING,
TDNEWID TYPE STRING,
TDCOVTITLE TYPE STRING,
SUBTYPE TYPE STRING,
LANGU TYPE STRING,
APPL_OBJECT_TYPE TYPE STRING,
APPL_OBJECT_ID TYPE STRING,
OUTPUT_TYPE TYPE STRING,
CHANNEL TYPE STRING,
FORM_TEMPLATE_NAME TYPE STRING,
FORM_TEMPLATE_COUNTRY_CODE TYPE STRING,
SENDER_ORGANIZATION_ID TYPE STRING,
SENDER_ORGANIZATION_TYPE TYPE STRING,
SENDER_ORG_UNIT_ID TYPE STRING,
SENDER_ORG_UNIT_TYPE TYPE STRING,
SENDER_COUNTRY_CODE TYPE STRING,
SENDER_EMAIL_URI TYPE STRING,
PRINT_QUEUE_NAME TYPE STRING,
AOID_SP TYPE STRING,
AOTYPE_SP TYPE STRING,
AONR_SP TYPE STRING,
PARTAOID_SP TYPE STRING,
XAO_SP TYPE STRING,
DOORPLT_SP TYPE STRING,
AOFUNCTION_SP TYPE STRING,END OF T_EKKO_STR. DATA: WA_RECP_SF_DOC_A110_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RECP_SF_DOC_A110_STR-BUSTYPE sy-vline
WA_RECP_SF_DOC_A110_STR-BUSKEY sy-vline
WA_RECP_SF_DOC_A110_STR-XMBUSOBJ sy-vline
WA_RECP_SF_DOC_A110_STR-BUKRS sy-vline
WA_RECP_SF_DOC_A110_STR-RESPONSIBLE sy-vline
WA_RECP_SF_DOC_A110_STR-INTRENO sy-vline
WA_RECP_SF_DOC_A110_STR-OBJNR sy-vline
WA_RECP_SF_DOC_A110_STR-OBJRELGUID sy-vline
WA_RECP_SF_DOC_A110_STR-PARTNER sy-vline
WA_RECP_SF_DOC_A110_STR-ROLE sy-vline
WA_RECP_SF_DOC_A110_STR-ADDRTYPE sy-vline
WA_RECP_SF_DOC_A110_STR-XPARTNER sy-vline
WA_RECP_SF_DOC_A110_STR-PARTN_CAT sy-vline
WA_RECP_SF_DOC_A110_STR-PARTN_GRP sy-vline
WA_RECP_SF_DOC_A110_STR-SEARCHTERM1 sy-vline
WA_RECP_SF_DOC_A110_STR-SEARCHTERM2 sy-vline
WA_RECP_SF_DOC_A110_STR-COMM_TYPE sy-vline
WA_RECP_SF_DOC_A110_STR-CPACT sy-vline
WA_RECP_SF_DOC_A110_STR-FMSEQNO sy-vline
WA_RECP_SF_DOC_A110_STR-RECIPGRP sy-vline
WA_RECP_SF_DOC_A110_STR-RECIPCATE sy-vline
WA_RECP_SF_DOC_A110_STR-RECIPROLE sy-vline
WA_RECP_SF_DOC_A110_STR-RECIPSUBROLE sy-vline
WA_RECP_SF_DOC_A110_STR-RECIPFINDHIER sy-vline
WA_RECP_SF_DOC_A110_STR-FNAME sy-vline
WA_RECP_SF_DOC_A110_STR-XFNAME sy-vline
WA_RECP_SF_DOC_A110_STR-FORMTYPE sy-vline
WA_RECP_SF_DOC_A110_STR-SFNAME sy-vline
WA_RECP_SF_DOC_A110_STR-TDCOPIESFM sy-vline
WA_RECP_SF_DOC_A110_STR-TDDEVICETYPE sy-vline
WA_RECP_SF_DOC_A110_STR-TDDEVICEICON sy-vline
WA_RECP_SF_DOC_A110_STR-XMAILORFAXNO sy-vline
WA_RECP_SF_DOC_A110_STR-TDNEWID sy-vline
WA_RECP_SF_DOC_A110_STR-TDCOVTITLE sy-vline
WA_RECP_SF_DOC_A110_STR-SUBTYPE sy-vline
WA_RECP_SF_DOC_A110_STR-LANGU sy-vline
WA_RECP_SF_DOC_A110_STR-APPL_OBJECT_TYPE sy-vline
WA_RECP_SF_DOC_A110_STR-APPL_OBJECT_ID sy-vline
WA_RECP_SF_DOC_A110_STR-OUTPUT_TYPE sy-vline
WA_RECP_SF_DOC_A110_STR-CHANNEL sy-vline
WA_RECP_SF_DOC_A110_STR-FORM_TEMPLATE_NAME sy-vline
WA_RECP_SF_DOC_A110_STR-FORM_TEMPLATE_COUNTRY_CODE sy-vline
WA_RECP_SF_DOC_A110_STR-SENDER_ORGANIZATION_ID sy-vline
WA_RECP_SF_DOC_A110_STR-SENDER_ORGANIZATION_TYPE sy-vline
WA_RECP_SF_DOC_A110_STR-SENDER_ORG_UNIT_ID sy-vline
WA_RECP_SF_DOC_A110_STR-SENDER_ORG_UNIT_TYPE sy-vline
WA_RECP_SF_DOC_A110_STR-SENDER_COUNTRY_CODE sy-vline
WA_RECP_SF_DOC_A110_STR-SENDER_EMAIL_URI sy-vline
WA_RECP_SF_DOC_A110_STR-PRINT_QUEUE_NAME sy-vline
WA_RECP_SF_DOC_A110_STR-AOID_SP sy-vline
WA_RECP_SF_DOC_A110_STR-AOTYPE_SP sy-vline
WA_RECP_SF_DOC_A110_STR-AONR_SP sy-vline
WA_RECP_SF_DOC_A110_STR-PARTAOID_SP sy-vline
WA_RECP_SF_DOC_A110_STR-XAO_SP sy-vline
WA_RECP_SF_DOC_A110_STR-DOORPLT_SP sy-vline
WA_RECP_SF_DOC_A110_STR-AOFUNCTION_SP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.