ABAP Select data from SAP table RECP_NA_VAL_C into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RECP_NA_VAL_C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RECP_NA_VAL_C. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RECP_NA_VAL_C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RECP_NA_VAL_C TYPE STANDARD TABLE OF RECP_NA_VAL_C,
      WA_RECP_NA_VAL_C TYPE RECP_NA_VAL_C,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RECP_NA_VAL_C> TYPE RECP_NA_VAL_C.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RECP_NA_VAL_C.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RECP_NA_VAL_C
  INTO TABLE IT_RECP_NA_VAL_C.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RECP_NA_VAL_C
*  INTO TABLE @DATA(IT_RECP_NA_VAL_C2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RECP_NA_VAL_C INDEX 1 INTO DATA(WA_RECP_NA_VAL_C2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RECP_NA_VAL_C ASSIGNING <RECP_NA_VAL_C>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RECP_NA_VAL_C>-MANDT = 1.
<RECP_NA_VAL_C>-INTRENO = 1.
<RECP_NA_VAL_C>-VALIDFROM = 1.
<RECP_NA_VAL_C>-VALIDTO = 1.
<RECP_NA_VAL_C>-ASSESSDATE = 1.
ENDLOOP.

LOOP AT IT_RECP_NA_VAL_C INTO WA_RECP_NA_VAL_C.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RECP_NA_VAL_C-ASSESSVALUE, sy-vline,
WA_RECP_NA_VAL_C-CURRENCY, sy-vline,
WA_RECP_NA_VAL_C-TAXVAL1, sy-vline,
WA_RECP_NA_VAL_C-TAXVAL2, sy-vline,
WA_RECP_NA_VAL_C-MEASVALUE, sy-vline,
WA_RECP_NA_VAL_C-MEASUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RECP_NA_VAL_C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RECP_NA_VAL_C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RECP_NA_VAL_C INTO WA_RECP_NA_VAL_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit REDAT, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RECP_NA_VAL_C-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_NA_VAL_C-VALIDTO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECP_NA_VAL_C-MEASUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_NA_VAL_C-MEASUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZONEMEASUNIT1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECP_NA_VAL_C-ZONEMEASUNIT1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_NA_VAL_C-ZONEMEASUNIT1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZONEMEASUNIT2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECP_NA_VAL_C-ZONEMEASUNIT2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_NA_VAL_C-ZONEMEASUNIT2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ZONEMEASUNIT3 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECP_NA_VAL_C-ZONEMEASUNIT3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_NA_VAL_C-ZONEMEASUNIT3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUNIT1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECP_NA_VAL_C-MEASUNIT1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_NA_VAL_C-MEASUNIT1.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUNIT2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECP_NA_VAL_C-MEASUNIT2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_NA_VAL_C-MEASUNIT2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUNIT3 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECP_NA_VAL_C-MEASUNIT3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_NA_VAL_C-MEASUNIT3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUNIT4 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECP_NA_VAL_C-MEASUNIT4 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_NA_VAL_C-MEASUNIT4.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEASUNIT5 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECP_NA_VAL_C-MEASUNIT5 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_NA_VAL_C-MEASUNIT5.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RECP_NA_VAL_C_STR,
MANDT TYPE STRING,
INTRENO TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
ASSESSDATE TYPE STRING,
ASSESSVALUE TYPE STRING,
CURRENCY TYPE STRING,
TAXVAL1 TYPE STRING,
TAXVAL2 TYPE STRING,
MEASVALUE TYPE STRING,
MEASUNIT TYPE STRING,
NAPRTYPE TYPE STRING,
LOCATION1 TYPE STRING,
LOCATION2 TYPE STRING,
SEARCHTERM TYPE STRING,
MCLOCATION1 TYPE STRING,
MCLOCATION2 TYPE STRING,
MCSEARCHTERM TYPE STRING,
NASTMNTTYPE TYPE STRING,
NAOWNREL TYPE STRING,
NAMETHOD TYPE STRING,
NAPRTYPEAR TYPE STRING,
ZONEMEAS1 TYPE STRING,
ZONEMEASUNIT1 TYPE STRING,
ZONEVALUE1 TYPE STRING,
ZONEMEAS2 TYPE STRING,
ZONEMEASUNIT2 TYPE STRING,
ZONEVALUE2 TYPE STRING,
ZONEMEAS3 TYPE STRING,
ZONEMEASUNIT3 TYPE STRING,
ZONEVALUE3 TYPE STRING,
PROPERTYVAL1 TYPE STRING,
BUILDINGVAL1 TYPE STRING,
GROUNDVAL TYPE STRING,
BASICVAL TYPE STRING,
CALCPERCENT TYPE STRING,
PROPERTYVAL2 TYPE STRING,
BUILDINGVAL2 TYPE STRING,
CALCVALUE TYPE STRING,
CALCDIFF TYPE STRING,
DIFFERENCE TYPE STRING,
MEAS1 TYPE STRING,
MEASUNIT1 TYPE STRING,
MEAS2 TYPE STRING,
MEASUNIT2 TYPE STRING,
MEAS3 TYPE STRING,
MEASUNIT3 TYPE STRING,
MEAS4 TYPE STRING,
MEASUNIT4 TYPE STRING,
MEAS5 TYPE STRING,
MEASUNIT5 TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
XNASTMNTTYPE TYPE STRING,
XNAOWNREL TYPE STRING,
XNAPRTYPEAR TYPE STRING,
XNAMETHOD TYPE STRING,
XDATERANGE TYPE STRING,
CUKY2ND TYPE STRING,
ASSESSVALUE2ND TYPE STRING,
TAXVAL12ND TYPE STRING,
ZONEVALUE12ND TYPE STRING,
ZONEVALUE22ND TYPE STRING,
ZONEVALUE32ND TYPE STRING,
PROPERTYVAL12ND TYPE STRING,
PROPERTYVAL22ND TYPE STRING,
GROUNDVAL2ND TYPE STRING,
BASICVAL2ND TYPE STRING,
BUILDINGVAL12ND TYPE STRING,
BUILDINGVAL22ND TYPE STRING,
CALCVALUE2ND TYPE STRING,
CALCDIFF2ND TYPE STRING,
MEAS12ND TYPE STRING,
MEAS22ND TYPE STRING,
MEAS32ND TYPE STRING,
MEAS42ND TYPE STRING,
MEAS52ND TYPE STRING,
MEASUNIT_OUT TYPE STRING,
ZONEMEASUNIT1_OUT TYPE STRING,
ZONEMEASUNIT2_OUT TYPE STRING,
ZONEMEASUNIT3_OUT TYPE STRING,
MEASUNIT1_OUT TYPE STRING,
MEASUNIT2_OUT TYPE STRING,
MEASUNIT3_OUT TYPE STRING,
MEASUNIT4_OUT TYPE STRING,
MEASUNIT5_OUT TYPE STRING,END OF T_EKKO_STR. DATA: WA_RECP_NA_VAL_C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RECP_NA_VAL_C_STR-MANDT sy-vline
WA_RECP_NA_VAL_C_STR-INTRENO sy-vline
WA_RECP_NA_VAL_C_STR-VALIDFROM sy-vline
WA_RECP_NA_VAL_C_STR-VALIDTO sy-vline
WA_RECP_NA_VAL_C_STR-ASSESSDATE sy-vline
WA_RECP_NA_VAL_C_STR-ASSESSVALUE sy-vline
WA_RECP_NA_VAL_C_STR-CURRENCY sy-vline
WA_RECP_NA_VAL_C_STR-TAXVAL1 sy-vline
WA_RECP_NA_VAL_C_STR-TAXVAL2 sy-vline
WA_RECP_NA_VAL_C_STR-MEASVALUE sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT sy-vline
WA_RECP_NA_VAL_C_STR-NAPRTYPE sy-vline
WA_RECP_NA_VAL_C_STR-LOCATION1 sy-vline
WA_RECP_NA_VAL_C_STR-LOCATION2 sy-vline
WA_RECP_NA_VAL_C_STR-SEARCHTERM sy-vline
WA_RECP_NA_VAL_C_STR-MCLOCATION1 sy-vline
WA_RECP_NA_VAL_C_STR-MCLOCATION2 sy-vline
WA_RECP_NA_VAL_C_STR-MCSEARCHTERM sy-vline
WA_RECP_NA_VAL_C_STR-NASTMNTTYPE sy-vline
WA_RECP_NA_VAL_C_STR-NAOWNREL sy-vline
WA_RECP_NA_VAL_C_STR-NAMETHOD sy-vline
WA_RECP_NA_VAL_C_STR-NAPRTYPEAR sy-vline
WA_RECP_NA_VAL_C_STR-ZONEMEAS1 sy-vline
WA_RECP_NA_VAL_C_STR-ZONEMEASUNIT1 sy-vline
WA_RECP_NA_VAL_C_STR-ZONEVALUE1 sy-vline
WA_RECP_NA_VAL_C_STR-ZONEMEAS2 sy-vline
WA_RECP_NA_VAL_C_STR-ZONEMEASUNIT2 sy-vline
WA_RECP_NA_VAL_C_STR-ZONEVALUE2 sy-vline
WA_RECP_NA_VAL_C_STR-ZONEMEAS3 sy-vline
WA_RECP_NA_VAL_C_STR-ZONEMEASUNIT3 sy-vline
WA_RECP_NA_VAL_C_STR-ZONEVALUE3 sy-vline
WA_RECP_NA_VAL_C_STR-PROPERTYVAL1 sy-vline
WA_RECP_NA_VAL_C_STR-BUILDINGVAL1 sy-vline
WA_RECP_NA_VAL_C_STR-GROUNDVAL sy-vline
WA_RECP_NA_VAL_C_STR-BASICVAL sy-vline
WA_RECP_NA_VAL_C_STR-CALCPERCENT sy-vline
WA_RECP_NA_VAL_C_STR-PROPERTYVAL2 sy-vline
WA_RECP_NA_VAL_C_STR-BUILDINGVAL2 sy-vline
WA_RECP_NA_VAL_C_STR-CALCVALUE sy-vline
WA_RECP_NA_VAL_C_STR-CALCDIFF sy-vline
WA_RECP_NA_VAL_C_STR-DIFFERENCE sy-vline
WA_RECP_NA_VAL_C_STR-MEAS1 sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT1 sy-vline
WA_RECP_NA_VAL_C_STR-MEAS2 sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT2 sy-vline
WA_RECP_NA_VAL_C_STR-MEAS3 sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT3 sy-vline
WA_RECP_NA_VAL_C_STR-MEAS4 sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT4 sy-vline
WA_RECP_NA_VAL_C_STR-MEAS5 sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT5 sy-vline
WA_RECP_NA_VAL_C_STR-RERF sy-vline
WA_RECP_NA_VAL_C_STR-DERF sy-vline
WA_RECP_NA_VAL_C_STR-TERF sy-vline
WA_RECP_NA_VAL_C_STR-REHER sy-vline
WA_RECP_NA_VAL_C_STR-RBEAR sy-vline
WA_RECP_NA_VAL_C_STR-DBEAR sy-vline
WA_RECP_NA_VAL_C_STR-TBEAR sy-vline
WA_RECP_NA_VAL_C_STR-RBHER sy-vline
WA_RECP_NA_VAL_C_STR-XNASTMNTTYPE sy-vline
WA_RECP_NA_VAL_C_STR-XNAOWNREL sy-vline
WA_RECP_NA_VAL_C_STR-XNAPRTYPEAR sy-vline
WA_RECP_NA_VAL_C_STR-XNAMETHOD sy-vline
WA_RECP_NA_VAL_C_STR-XDATERANGE sy-vline
WA_RECP_NA_VAL_C_STR-CUKY2ND sy-vline
WA_RECP_NA_VAL_C_STR-ASSESSVALUE2ND sy-vline
WA_RECP_NA_VAL_C_STR-TAXVAL12ND sy-vline
WA_RECP_NA_VAL_C_STR-ZONEVALUE12ND sy-vline
WA_RECP_NA_VAL_C_STR-ZONEVALUE22ND sy-vline
WA_RECP_NA_VAL_C_STR-ZONEVALUE32ND sy-vline
WA_RECP_NA_VAL_C_STR-PROPERTYVAL12ND sy-vline
WA_RECP_NA_VAL_C_STR-PROPERTYVAL22ND sy-vline
WA_RECP_NA_VAL_C_STR-GROUNDVAL2ND sy-vline
WA_RECP_NA_VAL_C_STR-BASICVAL2ND sy-vline
WA_RECP_NA_VAL_C_STR-BUILDINGVAL12ND sy-vline
WA_RECP_NA_VAL_C_STR-BUILDINGVAL22ND sy-vline
WA_RECP_NA_VAL_C_STR-CALCVALUE2ND sy-vline
WA_RECP_NA_VAL_C_STR-CALCDIFF2ND sy-vline
WA_RECP_NA_VAL_C_STR-MEAS12ND sy-vline
WA_RECP_NA_VAL_C_STR-MEAS22ND sy-vline
WA_RECP_NA_VAL_C_STR-MEAS32ND sy-vline
WA_RECP_NA_VAL_C_STR-MEAS42ND sy-vline
WA_RECP_NA_VAL_C_STR-MEAS52ND sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT_OUT sy-vline
WA_RECP_NA_VAL_C_STR-ZONEMEASUNIT1_OUT sy-vline
WA_RECP_NA_VAL_C_STR-ZONEMEASUNIT2_OUT sy-vline
WA_RECP_NA_VAL_C_STR-ZONEMEASUNIT3_OUT sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT1_OUT sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT2_OUT sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT3_OUT sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT4_OUT sy-vline
WA_RECP_NA_VAL_C_STR-MEASUNIT5_OUT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.