ABAP Select data from SAP table RECP_FDP_BUS_OBJECT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RECP_FDP_BUS_OBJECT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RECP_FDP_BUS_OBJECT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RECP_FDP_BUS_OBJECT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RECP_FDP_BUS_OBJECT TYPE STANDARD TABLE OF RECP_FDP_BUS_OBJECT,
      WA_RECP_FDP_BUS_OBJECT TYPE RECP_FDP_BUS_OBJECT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RECP_FDP_BUS_OBJECT> TYPE RECP_FDP_BUS_OBJECT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RECP_FDP_BUS_OBJECT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RECP_FDP_BUS_OBJECT
  INTO TABLE IT_RECP_FDP_BUS_OBJECT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RECP_FDP_BUS_OBJECT
*  INTO TABLE @DATA(IT_RECP_FDP_BUS_OBJECT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RECP_FDP_BUS_OBJECT INDEX 1 INTO DATA(WA_RECP_FDP_BUS_OBJECT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RECP_FDP_BUS_OBJECT ASSIGNING <RECP_FDP_BUS_OBJECT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RECP_FDP_BUS_OBJECT>-OBJTYPE = 1.
<RECP_FDP_BUS_OBJECT>-OBJNR = 1.
<RECP_FDP_BUS_OBJECT>-INTRENO = 1.
<RECP_FDP_BUS_OBJECT>-IMKEY = 1.
<RECP_FDP_BUS_OBJECT>-BUKRS = 1.
ENDLOOP.

LOOP AT IT_RECP_FDP_BUS_OBJECT INTO WA_RECP_FDP_BUS_OBJECT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RECP_FDP_BUS_OBJECT-BUSTYPE, sy-vline,
WA_RECP_FDP_BUS_OBJECT-BUSKEY, sy-vline,
WA_RECP_FDP_BUS_OBJECT-IDENTKEY, sy-vline,
WA_RECP_FDP_BUS_OBJECT-IDENT, sy-vline,
WA_RECP_FDP_BUS_OBJECT-XIDENT, sy-vline,
WA_RECP_FDP_BUS_OBJECT-XOBJTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RECP_FDP_BUS_OBJECT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RECP_FDP_BUS_OBJECT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RECP_FDP_BUS_OBJECT INTO WA_RECP_FDP_BUS_OBJECT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit IMKEY, internal->external for field IMKEY CALL FUNCTION 'CONVERSION_EXIT_IMKEY_OUTPUT' EXPORTING input = WA_RECP_FDP_BUS_OBJECT-IMKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_FDP_BUS_OBJECT-IMKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RECP_FDP_BUS_OBJECT-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_FDP_BUS_OBJECT-VALIDTO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RECP_FDP_BUS_OBJECT_STR,
OBJTYPE TYPE STRING,
OBJNR TYPE STRING,
INTRENO TYPE STRING,
IMKEY TYPE STRING,
BUKRS TYPE STRING,
BUSTYPE TYPE STRING,
BUSKEY TYPE STRING,
IDENTKEY TYPE STRING,
IDENT TYPE STRING,
XIDENT TYPE STRING,
XOBJTYPE TYPE STRING,
XLOBJTYPE TYPE STRING,
TEXT TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
RESPONSIBLE TYPE STRING,
USEREXCLUSIVE TYPE STRING,
AUTHGRP TYPE STRING,
XAUTHGRP TYPE STRING,
STTXT_INT TYPE STRING,
STTXT_EXT TYPE STRING,
XDATERANGE TYPE STRING,END OF T_EKKO_STR. DATA: WA_RECP_FDP_BUS_OBJECT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-OBJTYPE sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-OBJNR sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-INTRENO sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-IMKEY sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-BUKRS sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-BUSTYPE sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-BUSKEY sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-IDENTKEY sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-IDENT sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-XIDENT sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-XOBJTYPE sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-XLOBJTYPE sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-TEXT sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-VALIDFROM sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-VALIDTO sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-RERF sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-DERF sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-TERF sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-REHER sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-RBEAR sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-DBEAR sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-TBEAR sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-RBHER sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-RESPONSIBLE sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-USEREXCLUSIVE sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-AUTHGRP sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-XAUTHGRP sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-STTXT_INT sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-STTXT_EXT sy-vline
WA_RECP_FDP_BUS_OBJECT_STR-XDATERANGE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.