ABAP Select data from SAP table RECP_BUS_OBJECT_C into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RECP_BUS_OBJECT_C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RECP_BUS_OBJECT_C. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RECP_BUS_OBJECT_C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RECP_BUS_OBJECT_C TYPE STANDARD TABLE OF RECP_BUS_OBJECT_C,
      WA_RECP_BUS_OBJECT_C TYPE RECP_BUS_OBJECT_C,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RECP_BUS_OBJECT_C> TYPE RECP_BUS_OBJECT_C.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RECP_BUS_OBJECT_C.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RECP_BUS_OBJECT_C
  INTO TABLE IT_RECP_BUS_OBJECT_C.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RECP_BUS_OBJECT_C
*  INTO TABLE @DATA(IT_RECP_BUS_OBJECT_C2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RECP_BUS_OBJECT_C INDEX 1 INTO DATA(WA_RECP_BUS_OBJECT_C2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RECP_BUS_OBJECT_C ASSIGNING <RECP_BUS_OBJECT_C>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RECP_BUS_OBJECT_C>-OBJTYPE = 1.
<RECP_BUS_OBJECT_C>-OBJNR = 1.
<RECP_BUS_OBJECT_C>-INTRENO = 1.
<RECP_BUS_OBJECT_C>-IMKEY = 1.
<RECP_BUS_OBJECT_C>-BUKRS = 1.
ENDLOOP.

LOOP AT IT_RECP_BUS_OBJECT_C INTO WA_RECP_BUS_OBJECT_C.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RECP_BUS_OBJECT_C-BUSTYPE, sy-vline,
WA_RECP_BUS_OBJECT_C-BUSKEY, sy-vline,
WA_RECP_BUS_OBJECT_C-IDENTKEY, sy-vline,
WA_RECP_BUS_OBJECT_C-IDENT, sy-vline,
WA_RECP_BUS_OBJECT_C-XIDENT, sy-vline,
WA_RECP_BUS_OBJECT_C-XOBJTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RECP_BUS_OBJECT_C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RECP_BUS_OBJECT_C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RECP_BUS_OBJECT_C INTO WA_RECP_BUS_OBJECT_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit IMKEY, internal->external for field IMKEY CALL FUNCTION 'CONVERSION_EXIT_IMKEY_OUTPUT' EXPORTING input = WA_RECP_BUS_OBJECT_C-IMKEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_BUS_OBJECT_C-IMKEY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field VALIDTO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RECP_BUS_OBJECT_C-VALIDTO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECP_BUS_OBJECT_C-VALIDTO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RECP_BUS_OBJECT_C_STR,
OBJTYPE TYPE STRING,
OBJNR TYPE STRING,
INTRENO TYPE STRING,
IMKEY TYPE STRING,
BUKRS TYPE STRING,
BUSTYPE TYPE STRING,
BUSKEY TYPE STRING,
IDENTKEY TYPE STRING,
IDENT TYPE STRING,
XIDENT TYPE STRING,
XOBJTYPE TYPE STRING,
XLOBJTYPE TYPE STRING,
TEXT TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
RERF TYPE STRING,
DERF TYPE STRING,
TERF TYPE STRING,
REHER TYPE STRING,
RBEAR TYPE STRING,
DBEAR TYPE STRING,
TBEAR TYPE STRING,
RBHER TYPE STRING,
RESPONSIBLE TYPE STRING,
USEREXCLUSIVE TYPE STRING,
AUTHGRP TYPE STRING,
XAUTHGRP TYPE STRING,
STTXT_INT TYPE STRING,
STTXT_EXT TYPE STRING,
XDATERANGE TYPE STRING,END OF T_EKKO_STR. DATA: WA_RECP_BUS_OBJECT_C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RECP_BUS_OBJECT_C_STR-OBJTYPE sy-vline
WA_RECP_BUS_OBJECT_C_STR-OBJNR sy-vline
WA_RECP_BUS_OBJECT_C_STR-INTRENO sy-vline
WA_RECP_BUS_OBJECT_C_STR-IMKEY sy-vline
WA_RECP_BUS_OBJECT_C_STR-BUKRS sy-vline
WA_RECP_BUS_OBJECT_C_STR-BUSTYPE sy-vline
WA_RECP_BUS_OBJECT_C_STR-BUSKEY sy-vline
WA_RECP_BUS_OBJECT_C_STR-IDENTKEY sy-vline
WA_RECP_BUS_OBJECT_C_STR-IDENT sy-vline
WA_RECP_BUS_OBJECT_C_STR-XIDENT sy-vline
WA_RECP_BUS_OBJECT_C_STR-XOBJTYPE sy-vline
WA_RECP_BUS_OBJECT_C_STR-XLOBJTYPE sy-vline
WA_RECP_BUS_OBJECT_C_STR-TEXT sy-vline
WA_RECP_BUS_OBJECT_C_STR-VALIDFROM sy-vline
WA_RECP_BUS_OBJECT_C_STR-VALIDTO sy-vline
WA_RECP_BUS_OBJECT_C_STR-RERF sy-vline
WA_RECP_BUS_OBJECT_C_STR-DERF sy-vline
WA_RECP_BUS_OBJECT_C_STR-TERF sy-vline
WA_RECP_BUS_OBJECT_C_STR-REHER sy-vline
WA_RECP_BUS_OBJECT_C_STR-RBEAR sy-vline
WA_RECP_BUS_OBJECT_C_STR-DBEAR sy-vline
WA_RECP_BUS_OBJECT_C_STR-TBEAR sy-vline
WA_RECP_BUS_OBJECT_C_STR-RBHER sy-vline
WA_RECP_BUS_OBJECT_C_STR-RESPONSIBLE sy-vline
WA_RECP_BUS_OBJECT_C_STR-USEREXCLUSIVE sy-vline
WA_RECP_BUS_OBJECT_C_STR-AUTHGRP sy-vline
WA_RECP_BUS_OBJECT_C_STR-XAUTHGRP sy-vline
WA_RECP_BUS_OBJECT_C_STR-STTXT_INT sy-vline
WA_RECP_BUS_OBJECT_C_STR-STTXT_EXT sy-vline
WA_RECP_BUS_OBJECT_C_STR-XDATERANGE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.