ABAP Select data from SAP table RECP_AJR_RECCOMPOBJ_C into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RECP_AJR_RECCOMPOBJ_C table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RECP_AJR_RECCOMPOBJ_C. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RECP_AJR_RECCOMPOBJ_C table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RECP_AJR_RECCOMPOBJ_C TYPE STANDARD TABLE OF RECP_AJR_RECCOMPOBJ_C,
      WA_RECP_AJR_RECCOMPOBJ_C TYPE RECP_AJR_RECCOMPOBJ_C,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RECP_AJR_RECCOMPOBJ_C> TYPE RECP_AJR_RECCOMPOBJ_C.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RECP_AJR_RECCOMPOBJ_C.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RECP_AJR_RECCOMPOBJ_C
  INTO TABLE IT_RECP_AJR_RECCOMPOBJ_C.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RECP_AJR_RECCOMPOBJ_C
*  INTO TABLE @DATA(IT_RECP_AJR_RECCOMPOBJ_C2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RECP_AJR_RECCOMPOBJ_C INDEX 1 INTO DATA(WA_RECP_AJR_RECCOMPOBJ_C2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RECP_AJR_RECCOMPOBJ_C ASSIGNING <RECP_AJR_RECCOMPOBJ_C>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RECP_AJR_RECCOMPOBJ_C>-MANDT = 1.
<RECP_AJR_RECCOMPOBJ_C>-RECCOMPOBJGUID = 1.
<RECP_AJR_RECCOMPOBJ_C>-RECCOMPGUID = 1.
<RECP_AJR_RECCOMPOBJ_C>-PROCESSGUID = 1.
<RECP_AJR_RECCOMPOBJ_C>-INTRENO = 1.
ENDLOOP.

LOOP AT IT_RECP_AJR_RECCOMPOBJ_C INTO WA_RECP_AJR_RECCOMPOBJ_C.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RECP_AJR_RECCOMPOBJ_C-OBJECTINTRENO, sy-vline,
WA_RECP_AJR_RECCOMPOBJ_C-COMPUSETYPE, sy-vline,
WA_RECP_AJR_RECCOMPOBJ_C-CONTRACTINTRENO, sy-vline,
WA_RECP_AJR_RECCOMPOBJ_C-CONDGUID, sy-vline,
WA_RECP_AJR_RECCOMPOBJ_C-COMPMEASVALUE, sy-vline,
WA_RECP_AJR_RECCOMPOBJ_C-COMPVALUEMEAS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RECP_AJR_RECCOMPOBJ_C you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RECP_AJR_RECCOMPOBJ_C TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RECP_AJR_RECCOMPOBJ_C INTO WA_RECP_AJR_RECCOMPOBJ_C. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RECP_AJR_RECCOMPOBJ_C_STR,
MANDT TYPE STRING,
RECCOMPOBJGUID TYPE STRING,
RECCOMPGUID TYPE STRING,
PROCESSGUID TYPE STRING,
INTRENO TYPE STRING,
OBJECTINTRENO TYPE STRING,
COMPUSETYPE TYPE STRING,
CONTRACTINTRENO TYPE STRING,
CONDGUID TYPE STRING,
COMPMEASVALUE TYPE STRING,
COMPVALUEMEAS TYPE STRING,
UNITPRICE TYPE STRING,
CURRENCY TYPE STRING,
CONDVALUE TYPE STRING,
CALCVALUE TYPE STRING,
ORIGUNITPRICE TYPE STRING,
ORIGCURRENCY TYPE STRING,
ORIGCONDVALUE TYPE STRING,
ORIGCALCVALUE TYPE STRING,
ROIDENT TYPE STRING,
CNIDENT TYPE STRING,
CUKY2ND TYPE STRING,
CONDVALUE_2ND TYPE STRING,
ORIGCONDVALUE_2ND TYPE STRING,END OF T_EKKO_STR. DATA: WA_RECP_AJR_RECCOMPOBJ_C_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-MANDT sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-RECCOMPOBJGUID sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-RECCOMPGUID sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-PROCESSGUID sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-INTRENO sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-OBJECTINTRENO sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-COMPUSETYPE sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-CONTRACTINTRENO sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-CONDGUID sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-COMPMEASVALUE sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-COMPVALUEMEAS sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-UNITPRICE sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-CURRENCY sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-CONDVALUE sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-CALCVALUE sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-ORIGUNITPRICE sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-ORIGCURRENCY sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-ORIGCONDVALUE sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-ORIGCALCVALUE sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-ROIDENT sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-CNIDENT sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-CUKY2ND sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-CONDVALUE_2ND sy-vline
WA_RECP_AJR_RECCOMPOBJ_C_STR-ORIGCONDVALUE_2ND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.