ABAP Select data from SAP table RECN_CONTRACT_PL_SEARCH_ODATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RECN_CONTRACT_PL_SEARCH_ODATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RECN_CONTRACT_PL_SEARCH_ODATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RECN_CONTRACT_PL_SEARCH_ODATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RECN_CONTRACT_PL_SEARCH_ODATA TYPE STANDARD TABLE OF RECN_CONTRACT_PL_SEARCH_ODATA,
      WA_RECN_CONTRACT_PL_SEARCH_ODATA TYPE RECN_CONTRACT_PL_SEARCH_ODATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RECN_CONTRACT_PL_SEARCH_ODATA> TYPE RECN_CONTRACT_PL_SEARCH_ODATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RECN_CONTRACT_PL_SEARCH_ODATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RECN_CONTRACT_PL_SEARCH_ODATA
  INTO TABLE IT_RECN_CONTRACT_PL_SEARCH_ODATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RECN_CONTRACT_PL_SEARCH_ODATA
*  INTO TABLE @DATA(IT_RECN_CONTRACT_PL_SEARCH_ODATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RECN_CONTRACT_PL_SEARCH_ODATA INDEX 1 INTO DATA(WA_RECN_CONTRACT_PL_SEARCH_ODATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RECN_CONTRACT_PL_SEARCH_ODATA ASSIGNING <RECN_CONTRACT_PL_SEARCH_ODATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RECN_CONTRACT_PL_SEARCH_ODATA>-OBJID_I8 = 1.
<RECN_CONTRACT_PL_SEARCH_ODATA>-OBJNR = 1.
<RECN_CONTRACT_PL_SEARCH_ODATA>-LOCHIER = 1.
<RECN_CONTRACT_PL_SEARCH_ODATA>-PLSUBDIVNO = 1.
<RECN_CONTRACT_PL_SEARCH_ODATA>-PLNO = 1.
ENDLOOP.

LOOP AT IT_RECN_CONTRACT_PL_SEARCH_ODATA INTO WA_RECN_CONTRACT_PL_SEARCH_ODATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RECN_CONTRACT_PL_SEARCH_ODATA-XPL, sy-vline,
WA_RECN_CONTRACT_PL_SEARCH_ODATA-VALIDTO, sy-vline,
WA_RECN_CONTRACT_PL_SEARCH_ODATA-RESPONSIBLE, sy-vline,
WA_RECN_CONTRACT_PL_SEARCH_ODATA-AUTHGRP, sy-vline,
WA_RECN_CONTRACT_PL_SEARCH_ODATA-LOCSYS, sy-vline,
WA_RECN_CONTRACT_PL_SEARCH_ODATA-XLOCHIER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RECN_CONTRACT_PL_SEARCH_ODATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RECN_CONTRACT_PL_SEARCH_ODATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RECN_CONTRACT_PL_SEARCH_ODATA INTO WA_RECN_CONTRACT_PL_SEARCH_ODATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field PLSUBDIVNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RECN_CONTRACT_PL_SEARCH_ODATA-PLSUBDIVNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECN_CONTRACT_PL_SEARCH_ODATA-PLSUBDIVNO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit PLNO, internal->external for field PLNO CALL FUNCTION 'CONVERSION_EXIT_PLNO_OUTPUT' EXPORTING input = WA_RECN_CONTRACT_PL_SEARCH_ODATA-PLNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECN_CONTRACT_PL_SEARCH_ODATA-PLNO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RECN_CONTRACT_PL_SEARCH_ODATA_STR,
OBJID_I8 TYPE STRING,
OBJNR TYPE STRING,
LOCHIER TYPE STRING,
PLSUBDIVNO TYPE STRING,
PLNO TYPE STRING,
XPL TYPE STRING,
VALIDTO TYPE STRING,
RESPONSIBLE TYPE STRING,
AUTHGRP TYPE STRING,
LOCSYS TYPE STRING,
XLOCHIER TYPE STRING,
XLOCHIERUPC TYPE STRING,
LOCITEM01 TYPE STRING,
LOCITEM02 TYPE STRING,
LOCITEM03 TYPE STRING,
LOCITEM04 TYPE STRING,
LOCITEM05 TYPE STRING,
LOCITEM06 TYPE STRING,
LOCITEM07 TYPE STRING,
LOCITEM08 TYPE STRING,
LOCITEM09 TYPE STRING,END OF T_EKKO_STR. DATA: WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-OBJID_I8 sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-OBJNR sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCHIER sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-PLSUBDIVNO sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-PLNO sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-XPL sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-VALIDTO sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-RESPONSIBLE sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-AUTHGRP sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCSYS sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-XLOCHIER sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-XLOCHIERUPC sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCITEM01 sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCITEM02 sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCITEM03 sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCITEM04 sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCITEM05 sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCITEM06 sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCITEM07 sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCITEM08 sy-vline
WA_RECN_CONTRACT_PL_SEARCH_ODATA_STR-LOCITEM09 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.