ABAP Select data from SAP table RECD_CONDITION_FILTER into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RECD_CONDITION_FILTER table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RECD_CONDITION_FILTER. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RECD_CONDITION_FILTER table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RECD_CONDITION_FILTER TYPE STANDARD TABLE OF RECD_CONDITION_FILTER,
      WA_RECD_CONDITION_FILTER TYPE RECD_CONDITION_FILTER,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RECD_CONDITION_FILTER> TYPE RECD_CONDITION_FILTER.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RECD_CONDITION_FILTER.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RECD_CONDITION_FILTER
  INTO TABLE IT_RECD_CONDITION_FILTER.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RECD_CONDITION_FILTER
*  INTO TABLE @DATA(IT_RECD_CONDITION_FILTER2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RECD_CONDITION_FILTER INDEX 1 INTO DATA(WA_RECD_CONDITION_FILTER2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RECD_CONDITION_FILTER ASSIGNING <RECD_CONDITION_FILTER>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RECD_CONDITION_FILTER>-CONDPURPOSE_NO = 1.
<RECD_CONDITION_FILTER>-CONDPURPOSE_FROM = 1.
<RECD_CONDITION_FILTER>-CONDPURPOSE_TO = 1.
<RECD_CONDITION_FILTER>-CONDTYPE_NO = 1.
<RECD_CONDITION_FILTER>-CONDTYPE_FROM = 1.
ENDLOOP.

LOOP AT IT_RECD_CONDITION_FILTER INTO WA_RECD_CONDITION_FILTER.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RECD_CONDITION_FILTER-CONDTYPE_TO, sy-vline,
WA_RECD_CONDITION_FILTER-VALIDFROM_NO, sy-vline,
WA_RECD_CONDITION_FILTER-VALIDFROM_FROM, sy-vline,
WA_RECD_CONDITION_FILTER-VALIDFROM_TO, sy-vline,
WA_RECD_CONDITION_FILTER-VALIDTO_NO, sy-vline,
WA_RECD_CONDITION_FILTER-VALIDTO_FROM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RECD_CONDITION_FILTER you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RECD_CONDITION_FILTER TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RECD_CONDITION_FILTER INTO WA_RECD_CONDITION_FILTER. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CONDTYPE_FROM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RECD_CONDITION_FILTER-CONDTYPE_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECD_CONDITION_FILTER-CONDTYPE_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CONDTYPE_TO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RECD_CONDITION_FILTER-CONDTYPE_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECD_CONDITION_FILTER-CONDTYPE_TO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field VALIDTO_FROM CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RECD_CONDITION_FILTER-VALIDTO_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECD_CONDITION_FILTER-VALIDTO_FROM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit REDAT, internal->external for field VALIDTO_TO CALL FUNCTION 'CONVERSION_EXIT_REDAT_OUTPUT' EXPORTING input = WA_RECD_CONDITION_FILTER-VALIDTO_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECD_CONDITION_FILTER-VALIDTO_TO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RECD_CONDITION_FILTER_STR,
CONDPURPOSE_NO TYPE STRING,
CONDPURPOSE_FROM TYPE STRING,
CONDPURPOSE_TO TYPE STRING,
CONDTYPE_NO TYPE STRING,
CONDTYPE_FROM TYPE STRING,
CONDTYPE_TO TYPE STRING,
VALIDFROM_NO TYPE STRING,
VALIDFROM_FROM TYPE STRING,
VALIDFROM_TO TYPE STRING,
VALIDTO_NO TYPE STRING,
VALIDTO_FROM TYPE STRING,
VALIDTO_TO TYPE STRING,END OF T_EKKO_STR. DATA: WA_RECD_CONDITION_FILTER_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RECD_CONDITION_FILTER_STR-CONDPURPOSE_NO sy-vline
WA_RECD_CONDITION_FILTER_STR-CONDPURPOSE_FROM sy-vline
WA_RECD_CONDITION_FILTER_STR-CONDPURPOSE_TO sy-vline
WA_RECD_CONDITION_FILTER_STR-CONDTYPE_NO sy-vline
WA_RECD_CONDITION_FILTER_STR-CONDTYPE_FROM sy-vline
WA_RECD_CONDITION_FILTER_STR-CONDTYPE_TO sy-vline
WA_RECD_CONDITION_FILTER_STR-VALIDFROM_NO sy-vline
WA_RECD_CONDITION_FILTER_STR-VALIDFROM_FROM sy-vline
WA_RECD_CONDITION_FILTER_STR-VALIDFROM_TO sy-vline
WA_RECD_CONDITION_FILTER_STR-VALIDTO_NO sy-vline
WA_RECD_CONDITION_FILTER_STR-VALIDTO_FROM sy-vline
WA_RECD_CONDITION_FILTER_STR-VALIDTO_TO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.