ABAP Select data from SAP table RECAC_COMPANY_CODE_SETTING into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RECAC_COMPANY_CODE_SETTING table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RECAC_COMPANY_CODE_SETTING. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RECAC_COMPANY_CODE_SETTING table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RECAC_COMPANY_CODE_SETTING TYPE STANDARD TABLE OF RECAC_COMPANY_CODE_SETTING,
      WA_RECAC_COMPANY_CODE_SETTING TYPE RECAC_COMPANY_CODE_SETTING,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RECAC_COMPANY_CODE_SETTING> TYPE RECAC_COMPANY_CODE_SETTING.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RECAC_COMPANY_CODE_SETTING.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RECAC_COMPANY_CODE_SETTING
  INTO TABLE IT_RECAC_COMPANY_CODE_SETTING.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RECAC_COMPANY_CODE_SETTING
*  INTO TABLE @DATA(IT_RECAC_COMPANY_CODE_SETTING2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RECAC_COMPANY_CODE_SETTING INDEX 1 INTO DATA(WA_RECAC_COMPANY_CODE_SETTING2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RECAC_COMPANY_CODE_SETTING ASSIGNING <RECAC_COMPANY_CODE_SETTING>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RECAC_COMPANY_CODE_SETTING>-MANDT = 1.
<RECAC_COMPANY_CODE_SETTING>-BUKRS = 1.
<RECAC_COMPANY_CODE_SETTING>-HASCTCDCURR = 1.
<RECAC_COMPANY_CODE_SETTING>-DEFCDCURR = 1.
<RECAC_COMPANY_CODE_SETTING>-DEFAULTAREA = 1.
ENDLOOP.

LOOP AT IT_RECAC_COMPANY_CODE_SETTING INTO WA_RECAC_COMPANY_CODE_SETTING.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RECAC_COMPANY_CODE_SETTING-DEFAULTVOLUME, sy-vline,
WA_RECAC_COMPANY_CODE_SETTING-DEFAULTLENGTH, sy-vline,
WA_RECAC_COMPANY_CODE_SETTING-ISAMMULTIASS, sy-vline,
WA_RECAC_COMPANY_CODE_SETTING-ISPMMULTIASS, sy-vline,
WA_RECAC_COMPANY_CODE_SETTING-ISPSMULTIASS, sy-vline,
WA_RECAC_COMPANY_CODE_SETTING-ISORMULTIASS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RECAC_COMPANY_CODE_SETTING you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RECAC_COMPANY_CODE_SETTING TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RECAC_COMPANY_CODE_SETTING INTO WA_RECAC_COMPANY_CODE_SETTING. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field DEFAULTAREA CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECAC_COMPANY_CODE_SETTING-DEFAULTAREA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECAC_COMPANY_CODE_SETTING-DEFAULTAREA.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DEFAULTVOLUME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECAC_COMPANY_CODE_SETTING-DEFAULTVOLUME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECAC_COMPANY_CODE_SETTING-DEFAULTVOLUME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field DEFAULTLENGTH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RECAC_COMPANY_CODE_SETTING-DEFAULTLENGTH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RECAC_COMPANY_CODE_SETTING-DEFAULTLENGTH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RECAC_COMPANY_CODE_SETTING_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
HASCTCDCURR TYPE STRING,
DEFCDCURR TYPE STRING,
DEFAULTAREA TYPE STRING,
DEFAULTVOLUME TYPE STRING,
DEFAULTLENGTH TYPE STRING,
ISAMMULTIASS TYPE STRING,
ISPMMULTIASS TYPE STRING,
ISPSMULTIASS TYPE STRING,
ISORMULTIASS TYPE STRING,
ISCCMULTIASS TYPE STRING,
ISAMOBLIGATORY TYPE STRING,
FIRSTDATE TYPE STRING,
AFA_RE TYPE STRING,
AFASL TYPE STRING,
FCOMACTIVE TYPE STRING,
FCOMACTIVEFROM TYPE STRING,
HASTAXDIST TYPE STRING,
TAXDSPS TYPE STRING,
TAXDSPM TYPE STRING,
TAXDSOR TYPE STRING,
TAXDSKS TYPE STRING,
TAXDSMSGPS TYPE STRING,
TAXDSMSGPM TYPE STRING,
TAXDSMSGOR TYPE STRING,
TAXDSMSGKS TYPE STRING,
DATEOFSERVSRC TYPE STRING,
TAXCORRIND TYPE STRING,
CCTYPE TYPE STRING,
DEFHBKID TYPE STRING,
DEFHKTID TYPE STRING,
NRINTINVOICE TYPE STRING,
NRINTCREDITMEMO TYPE STRING,
NODOCUPDATE TYPE STRING,
ACCSYSTEM TYPE STRING,
CNDSPOS TYPE STRING,
CNDSTAX TYPE STRING,
HASPARTNERBLOCK TYPE STRING,
CREATENEWITEMS TYPE STRING,
FILLASSDOCUMENT TYPE STRING,
FILLBUSAREA TYPE STRING,
HASTAXACCRUAL TYPE STRING,
HASACRPSTDATEDEP TYPE STRING,
INPTAXZEROTYPE TYPE STRING,
INPTAXZEROGROUP TYPE STRING,
OUTTAXZEROTYPE TYPE STRING,
OUTTAXZEROGROUP TYPE STRING,
DISTCOMPLETE TYPE STRING,
FILLSEPAMANDATE TYPE STRING,
CVCREATE TYPE STRING,
CANMSUASSIGNMSU TYPE STRING,
SUPURPSUBSTIND TYPE STRING,
NOTAXCORR TYPE STRING,
MEASPOINTTYPE TYPE STRING,
USECF4POST TYPE STRING,END OF T_EKKO_STR. DATA: WA_RECAC_COMPANY_CODE_SETTING_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-MANDT sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-BUKRS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-HASCTCDCURR sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-DEFCDCURR sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-DEFAULTAREA sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-DEFAULTVOLUME sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-DEFAULTLENGTH sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-ISAMMULTIASS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-ISPMMULTIASS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-ISPSMULTIASS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-ISORMULTIASS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-ISCCMULTIASS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-ISAMOBLIGATORY sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-FIRSTDATE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-AFA_RE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-AFASL sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-FCOMACTIVE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-FCOMACTIVEFROM sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-HASTAXDIST sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-TAXDSPS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-TAXDSPM sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-TAXDSOR sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-TAXDSKS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-TAXDSMSGPS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-TAXDSMSGPM sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-TAXDSMSGOR sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-TAXDSMSGKS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-DATEOFSERVSRC sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-TAXCORRIND sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-CCTYPE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-DEFHBKID sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-DEFHKTID sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-NRINTINVOICE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-NRINTCREDITMEMO sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-NODOCUPDATE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-ACCSYSTEM sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-CNDSPOS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-CNDSTAX sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-HASPARTNERBLOCK sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-CREATENEWITEMS sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-FILLASSDOCUMENT sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-FILLBUSAREA sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-HASTAXACCRUAL sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-HASACRPSTDATEDEP sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-INPTAXZEROTYPE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-INPTAXZEROGROUP sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-OUTTAXZEROTYPE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-OUTTAXZEROGROUP sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-DISTCOMPLETE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-FILLSEPAMANDATE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-CVCREATE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-CANMSUASSIGNMSU sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-SUPURPSUBSTIND sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-NOTAXCORR sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-MEASPOINTTYPE sy-vline
WA_RECAC_COMPANY_CODE_SETTING_STR-USECF4POST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.