ABAP Select data from SAP table REBW_RECN_ATTR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP REBW_RECN_ATTR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to REBW_RECN_ATTR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the REBW_RECN_ATTR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_REBW_RECN_ATTR TYPE STANDARD TABLE OF REBW_RECN_ATTR,
      WA_REBW_RECN_ATTR TYPE REBW_RECN_ATTR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <REBW_RECN_ATTR> TYPE REBW_RECN_ATTR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_REBW_RECN_ATTR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM REBW_RECN_ATTR
  INTO TABLE IT_REBW_RECN_ATTR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM REBW_RECN_ATTR
*  INTO TABLE @DATA(IT_REBW_RECN_ATTR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_REBW_RECN_ATTR INDEX 1 INTO DATA(WA_REBW_RECN_ATTR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_REBW_RECN_ATTR ASSIGNING <REBW_RECN_ATTR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<REBW_RECN_ATTR>-BUKRS = 1.
<REBW_RECN_ATTR>-RECNNR = 1.
<REBW_RECN_ATTR>-RECNBEG = 1.
<REBW_RECN_ATTR>-RECNEND = 1.
<REBW_RECN_ATTR>-RECNADJT = 1.
ENDLOOP.

LOOP AT IT_REBW_RECN_ATTR INTO WA_REBW_RECN_ATTR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_REBW_RECN_ATTR-RECNOBJNR, sy-vline,
WA_REBW_RECN_ATTR-RECNNOTTYPE, sy-vline,
WA_REBW_RECN_ATTR-RECNNOTKEY, sy-vline,
WA_REBW_RECN_ATTR-RECNNOTPER, sy-vline,
WA_REBW_RECN_ATTR-RECNBUSAREA, sy-vline,
WA_REBW_RECN_ATTR-RECNPRCTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_REBW_RECN_ATTR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_REBW_RECN_ATTR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_REBW_RECN_ATTR INTO WA_REBW_RECN_ATTR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REBW_RECN_ATTR-RECNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REBW_RECN_ATTR-RECNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNPRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REBW_RECN_ATTR-RECNPRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REBW_RECN_ATTR-RECNPRCTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNNRCOLLECT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REBW_RECN_ATTR-RECNNRCOLLECT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REBW_RECN_ATTR-RECNNRCOLLECT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNKOSTL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REBW_RECN_ATTR-RECNKOSTL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REBW_RECN_ATTR-RECNKOSTL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GP0600 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REBW_RECN_ATTR-GP0600 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REBW_RECN_ATTR-GP0600.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_REBW_RECN_ATTR_STR,
BUKRS TYPE STRING,
RECNNR TYPE STRING,
RECNBEG TYPE STRING,
RECNEND TYPE STRING,
RECNADJT TYPE STRING,
RECNOBJNR TYPE STRING,
RECNNOTTYPE TYPE STRING,
RECNNOTKEY TYPE STRING,
RECNNOTPER TYPE STRING,
RECNBUSAREA TYPE STRING,
RECNPRCTR TYPE STRING,
RECNTLAW TYPE STRING,
RECNNRCOLLECT TYPE STRING,
RECNKOSTL TYPE STRING,
RECNNOTREASON TYPE STRING,
RECNNOTCAT TYPE STRING,
RECNBUKRSCOLLECT TYPE STRING,
INTRENO TYPE STRING,
RECNTYPE TYPE STRING,
DNEXTNOT TYPE STRING,
CONDTOT TYPE STRING,
CONDNET TYPE STRING,
CONDTAX TYPE STRING,
WAERS TYPE STRING,
GP0600 TYPE STRING,
FL_RECN TYPE STRING,
DATEFROM TYPE STRING,
DATETO TYPE STRING,END OF T_EKKO_STR. DATA: WA_REBW_RECN_ATTR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_REBW_RECN_ATTR_STR-BUKRS sy-vline
WA_REBW_RECN_ATTR_STR-RECNNR sy-vline
WA_REBW_RECN_ATTR_STR-RECNBEG sy-vline
WA_REBW_RECN_ATTR_STR-RECNEND sy-vline
WA_REBW_RECN_ATTR_STR-RECNADJT sy-vline
WA_REBW_RECN_ATTR_STR-RECNOBJNR sy-vline
WA_REBW_RECN_ATTR_STR-RECNNOTTYPE sy-vline
WA_REBW_RECN_ATTR_STR-RECNNOTKEY sy-vline
WA_REBW_RECN_ATTR_STR-RECNNOTPER sy-vline
WA_REBW_RECN_ATTR_STR-RECNBUSAREA sy-vline
WA_REBW_RECN_ATTR_STR-RECNPRCTR sy-vline
WA_REBW_RECN_ATTR_STR-RECNTLAW sy-vline
WA_REBW_RECN_ATTR_STR-RECNNRCOLLECT sy-vline
WA_REBW_RECN_ATTR_STR-RECNKOSTL sy-vline
WA_REBW_RECN_ATTR_STR-RECNNOTREASON sy-vline
WA_REBW_RECN_ATTR_STR-RECNNOTCAT sy-vline
WA_REBW_RECN_ATTR_STR-RECNBUKRSCOLLECT sy-vline
WA_REBW_RECN_ATTR_STR-INTRENO sy-vline
WA_REBW_RECN_ATTR_STR-RECNTYPE sy-vline
WA_REBW_RECN_ATTR_STR-DNEXTNOT sy-vline
WA_REBW_RECN_ATTR_STR-CONDTOT sy-vline
WA_REBW_RECN_ATTR_STR-CONDNET sy-vline
WA_REBW_RECN_ATTR_STR-CONDTAX sy-vline
WA_REBW_RECN_ATTR_STR-WAERS sy-vline
WA_REBW_RECN_ATTR_STR-GP0600 sy-vline
WA_REBW_RECN_ATTR_STR-FL_RECN sy-vline
WA_REBW_RECN_ATTR_STR-DATEFROM sy-vline
WA_REBW_RECN_ATTR_STR-DATETO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.