ABAP Select data from SAP table REBDC_FIXFITCHARACT_X into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP REBDC_FIXFITCHARACT_X table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to REBDC_FIXFITCHARACT_X. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the REBDC_FIXFITCHARACT_X table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_REBDC_FIXFITCHARACT_X TYPE STANDARD TABLE OF REBDC_FIXFITCHARACT_X,
      WA_REBDC_FIXFITCHARACT_X TYPE REBDC_FIXFITCHARACT_X,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <REBDC_FIXFITCHARACT_X> TYPE REBDC_FIXFITCHARACT_X.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_REBDC_FIXFITCHARACT_X.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM REBDC_FIXFITCHARACT_X
  INTO TABLE IT_REBDC_FIXFITCHARACT_X.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM REBDC_FIXFITCHARACT_X
*  INTO TABLE @DATA(IT_REBDC_FIXFITCHARACT_X2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_REBDC_FIXFITCHARACT_X INDEX 1 INTO DATA(WA_REBDC_FIXFITCHARACT_X2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_REBDC_FIXFITCHARACT_X ASSIGNING <REBDC_FIXFITCHARACT_X>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<REBDC_FIXFITCHARACT_X>-MANDT = 1.
<REBDC_FIXFITCHARACT_X>-FIXFITCHARACT = 1.
<REBDC_FIXFITCHARACT_X>-RELEVANTRO = 1.
<REBDC_FIXFITCHARACT_X>-RELEVANTBU = 1.
<REBDC_FIXFITCHARACT_X>-RELEVANTPL = 1.
ENDLOOP.

LOOP AT IT_REBDC_FIXFITCHARACT_X INTO WA_REBDC_FIXFITCHARACT_X.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_REBDC_FIXFITCHARACT_X-USAGECATE, sy-vline,
WA_REBDC_FIXFITCHARACT_X-TAKEONLYIFRLRA, sy-vline,
WA_REBDC_FIXFITCHARACT_X-FFCTHASCOUNT, sy-vline,
WA_REBDC_FIXFITCHARACT_X-CUEXCLUDEASSIGN, sy-vline,
WA_REBDC_FIXFITCHARACT_X-SPRAS, sy-vline,
WA_REBDC_FIXFITCHARACT_X-XFIXFITCHARACT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_REBDC_FIXFITCHARACT_X you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_REBDC_FIXFITCHARACT_X TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_REBDC_FIXFITCHARACT_X INTO WA_REBDC_FIXFITCHARACT_X. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field FIXFITCHARACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REBDC_FIXFITCHARACT_X-FIXFITCHARACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REBDC_FIXFITCHARACT_X-FIXFITCHARACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_REBDC_FIXFITCHARACT_X-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REBDC_FIXFITCHARACT_X-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_REBDC_FIXFITCHARACT_X_STR,
MANDT TYPE STRING,
FIXFITCHARACT TYPE STRING,
RELEVANTRO TYPE STRING,
RELEVANTBU TYPE STRING,
RELEVANTPL TYPE STRING,
USAGECATE TYPE STRING,
TAKEONLYIFRLRA TYPE STRING,
FFCTHASCOUNT TYPE STRING,
CUEXCLUDEASSIGN TYPE STRING,
SPRAS TYPE STRING,
XFIXFITCHARACT TYPE STRING,
RELEVANTRLRA TYPE STRING,
FFCTBUILDING TYPE STRING,END OF T_EKKO_STR. DATA: WA_REBDC_FIXFITCHARACT_X_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-MANDT sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-FIXFITCHARACT sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-RELEVANTRO sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-RELEVANTBU sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-RELEVANTPL sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-USAGECATE sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-TAKEONLYIFRLRA sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-FFCTHASCOUNT sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-CUEXCLUDEASSIGN sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-SPRAS sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-XFIXFITCHARACT sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-RELEVANTRLRA sy-vline
WA_REBDC_FIXFITCHARACT_X_STR-FFCTBUILDING sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.