ABAP Select data from SAP table REBD_BUILDING_IDENT_CI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP REBD_BUILDING_IDENT_CI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to REBD_BUILDING_IDENT_CI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the REBD_BUILDING_IDENT_CI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_REBD_BUILDING_IDENT_CI TYPE STANDARD TABLE OF REBD_BUILDING_IDENT_CI,
      WA_REBD_BUILDING_IDENT_CI TYPE REBD_BUILDING_IDENT_CI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <REBD_BUILDING_IDENT_CI> TYPE REBD_BUILDING_IDENT_CI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_REBD_BUILDING_IDENT_CI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM REBD_BUILDING_IDENT_CI
  INTO TABLE IT_REBD_BUILDING_IDENT_CI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM REBD_BUILDING_IDENT_CI
*  INTO TABLE @DATA(IT_REBD_BUILDING_IDENT_CI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_REBD_BUILDING_IDENT_CI INDEX 1 INTO DATA(WA_REBD_BUILDING_IDENT_CI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_REBD_BUILDING_IDENT_CI ASSIGNING <REBD_BUILDING_IDENT_CI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<REBD_BUILDING_IDENT_CI>-OBJNR = 1.
<REBD_BUILDING_IDENT_CI>-OBJTYPE = 1.
<REBD_BUILDING_IDENT_CI>-OBJID = 1.
<REBD_BUILDING_IDENT_CI>-DUMMYFIELD = 1.
<REBD_BUILDING_IDENT_CI>-OBJCOND = 1.
ENDLOOP.

LOOP AT IT_REBD_BUILDING_IDENT_CI INTO WA_REBD_BUILDING_IDENT_CI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_REBD_BUILDING_IDENT_CI-OBJCAT, sy-vline,
WA_REBD_BUILDING_IDENT_CI-YEARDECONSTR, sy-vline,
WA_REBD_BUILDING_IDENT_CI-AREAVALUE, sy-vline,
WA_REBD_BUILDING_IDENT_CI-HEATINGTYPE, sy-vline,
WA_REBD_BUILDING_IDENT_CI-ENERGYHEAT, sy-vline,
WA_REBD_BUILDING_IDENT_CI-ENERGYWATER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_REBD_BUILDING_IDENT_CI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_REBD_BUILDING_IDENT_CI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_REBD_BUILDING_IDENT_CI INTO WA_REBD_BUILDING_IDENT_CI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ADMINNO CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_REBD_BUILDING_IDENT_CI-ADMINNO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REBD_BUILDING_IDENT_CI-ADMINNO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_REBD_BUILDING_IDENT_CI_STR,
OBJNR TYPE STRING,
OBJTYPE TYPE STRING,
OBJID TYPE STRING,
DUMMYFIELD TYPE STRING,
OBJCOND TYPE STRING,
OBJCAT TYPE STRING,
YEARDECONSTR TYPE STRING,
AREAVALUE TYPE STRING,
HEATINGTYPE TYPE STRING,
ENERGYHEAT TYPE STRING,
ENERGYWATER TYPE STRING,
HOTWATERSUPPLY TYPE STRING,
POWERCONSUM TYPE STRING,
GLAZING TYPE STRING,
ADMINNO TYPE STRING,
ADMINXGETXT TYPE STRING,
GEMEINDECH TYPE STRING,
BANZGECH TYPE STRING,
SSTCKBISCH TYPE STRING,
SLIFTBISCH TYPE STRING,
AUGESCHCH TYPE STRING,
SECCO TYPE STRING,
BUPLA TYPE STRING,
REPKOCH TYPE STRING,
BDCONSTR TYPE STRING,
BDFIREPREV TYPE STRING,
BDOTHOW TYPE STRING,
BDOWNSHIP TYPE STRING,
KOCHDATE TYPE STRING,
VPT TYPE STRING,
CURRENCY TYPE STRING,
CONDK TYPE STRING,END OF T_EKKO_STR. DATA: WA_REBD_BUILDING_IDENT_CI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-OBJNR sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-OBJTYPE sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-OBJID sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-DUMMYFIELD sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-OBJCOND sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-OBJCAT sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-YEARDECONSTR sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-AREAVALUE sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-HEATINGTYPE sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-ENERGYHEAT sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-ENERGYWATER sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-HOTWATERSUPPLY sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-POWERCONSUM sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-GLAZING sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-ADMINNO sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-ADMINXGETXT sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-GEMEINDECH sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-BANZGECH sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-SSTCKBISCH sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-SLIFTBISCH sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-AUGESCHCH sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-SECCO sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-BUPLA sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-REPKOCH sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-BDCONSTR sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-BDFIREPREV sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-BDOTHOW sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-BDOWNSHIP sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-KOCHDATE sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-VPT sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-CURRENCY sy-vline
WA_REBD_BUILDING_IDENT_CI_STR-CONDK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.