ABAP Select data from SAP table REA70 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP REA70 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to REA70. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the REA70 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_REA70 TYPE STANDARD TABLE OF REA70,
      WA_REA70 TYPE REA70,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <REA70> TYPE REA70.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_REA70.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM REA70
  INTO TABLE IT_REA70.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM REA70
*  INTO TABLE @DATA(IT_REA702).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_REA70 INDEX 1 INTO DATA(WA_REA702).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_REA70 ASSIGNING <REA70>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<REA70>-MANDT = 1.
<REA70>-SPRAS = 1.
<REA70>-BWVERF = 1.
<REA70>-CALOR_AREA = 1.
<REA70>-GEPFLEGT = 1.
ENDLOOP.

LOOP AT IT_REA70 INTO WA_REA70.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_REA70-DATMOJA, sy-vline,
WA_REA70-BRENNWTA, sy-vline,
WA_REA70-BRENNWTF, sy-vline,
WA_REA70-BRENNWTM, sy-vline,
WA_REA70-PROZABW, sy-vline,
ENDLOOP. *Add any further fields from structure WA_REA70 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_REA70 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_REA70 INTO WA_REA70. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_REA70-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REA70-SPRAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit JJ_MM, internal->external for field DATMOJA CALL FUNCTION 'CONVERSION_EXIT_JJ_MM_OUTPUT' EXPORTING input = WA_REA70-DATMOJA IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_REA70-DATMOJA.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_REA70_STR,
MANDT TYPE STRING,
SPRAS TYPE STRING,
BWVERF TYPE STRING,
CALOR_AREA TYPE STRING,
GEPFLEGT TYPE STRING,
DATMOJA TYPE STRING,
BRENNWTA TYPE STRING,
BRENNWTF TYPE STRING,
BRENNWTM TYPE STRING,
PROZABW TYPE STRING,END OF T_EKKO_STR. DATA: WA_REA70_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_REA70_STR-MANDT sy-vline
WA_REA70_STR-SPRAS sy-vline
WA_REA70_STR-BWVERF sy-vline
WA_REA70_STR-CALOR_AREA sy-vline
WA_REA70_STR-GEPFLEGT sy-vline
WA_REA70_STR-DATMOJA sy-vline
WA_REA70_STR-BRENNWTA sy-vline
WA_REA70_STR-BRENNWTF sy-vline
WA_REA70_STR-BRENNWTM sy-vline
WA_REA70_STR-PROZABW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.