ABAP Select data from SAP table RCGTPLHIOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCGTPLHIOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCGTPLHIOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RCGTPLHIOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RCGTPLHIOT TYPE STANDARD TABLE OF RCGTPLHIOT,
      WA_RCGTPLHIOT TYPE RCGTPLHIOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RCGTPLHIOT> TYPE RCGTPLHIOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RCGTPLHIOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RCGTPLHIOT
  INTO TABLE IT_RCGTPLHIOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RCGTPLHIOT
*  INTO TABLE @DATA(IT_RCGTPLHIOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RCGTPLHIOT INDEX 1 INTO DATA(WA_RCGTPLHIOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RCGTPLHIOT ASSIGNING <RCGTPLHIOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCGTPLHIOT>-MANDT = 1.
<RCGTPLHIOT>-RECN_GRP = 1.
<RCGTPLHIOT>-AENNR = 1.
<RCGTPLHIOT>-SEARCHMODE = 1.
<RCGTPLHIOT>-VALDAT = 1.
ENDLOOP.

LOOP AT IT_RCGTPLHIOT INTO WA_RCGTPLHIOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RCGTPLHIOT-VALFR, sy-vline,
WA_RCGTPLHIOT-VALTO, sy-vline,
WA_RCGTPLHIOT-CRDAT, sy-vline,
WA_RCGTPLHIOT-CRNAM, sy-vline,
WA_RCGTPLHIOT-UPDDAT, sy-vline,
WA_RCGTPLHIOT-UPDNAM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCGTPLHIOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCGTPLHIOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCGTPLHIOT INTO WA_RCGTPLHIOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN_GRP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCGTPLHIOT-RECN_GRP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCGTPLHIOT-RECN_GRP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCGTPLHIOT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCGTPLHIOT-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECN_COLLISION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCGTPLHIOT-RECN_COLLISION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCGTPLHIOT-RECN_COLLISION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCGTPLHIOT_STR,
MANDT TYPE STRING,
RECN_GRP TYPE STRING,
AENNR TYPE STRING,
SEARCHMODE TYPE STRING,
VALDAT TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
OBJID TYPE STRING,
GRPID TYPE STRING,
ORD TYPE STRING,
FLG_DST_CHNG TYPE STRING,
FLG_INH_DSBL TYPE STRING,
FLG_INH_EXCL TYPE STRING,
FLG_ALL_PROP TYPE STRING,
FLG_ALL_IDENT TYPE STRING,
FLG_ALL_USAGES TYPE STRING,
MARKFLG TYPE STRING,
SELEFLG TYPE STRING,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
CHCOFLG TYPE STRING,
LOCKMOD TYPE STRING,
INTRFLG TYPE STRING,
RECN_COLLISION TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCGTPLHIOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCGTPLHIOT_STR-MANDT sy-vline
WA_RCGTPLHIOT_STR-RECN_GRP sy-vline
WA_RCGTPLHIOT_STR-AENNR sy-vline
WA_RCGTPLHIOT_STR-SEARCHMODE sy-vline
WA_RCGTPLHIOT_STR-VALDAT sy-vline
WA_RCGTPLHIOT_STR-VALFR sy-vline
WA_RCGTPLHIOT_STR-VALTO sy-vline
WA_RCGTPLHIOT_STR-CRDAT sy-vline
WA_RCGTPLHIOT_STR-CRNAM sy-vline
WA_RCGTPLHIOT_STR-UPDDAT sy-vline
WA_RCGTPLHIOT_STR-UPDNAM sy-vline
WA_RCGTPLHIOT_STR-OBJID sy-vline
WA_RCGTPLHIOT_STR-GRPID sy-vline
WA_RCGTPLHIOT_STR-ORD sy-vline
WA_RCGTPLHIOT_STR-FLG_DST_CHNG sy-vline
WA_RCGTPLHIOT_STR-FLG_INH_DSBL sy-vline
WA_RCGTPLHIOT_STR-FLG_INH_EXCL sy-vline
WA_RCGTPLHIOT_STR-FLG_ALL_PROP sy-vline
WA_RCGTPLHIOT_STR-FLG_ALL_IDENT sy-vline
WA_RCGTPLHIOT_STR-FLG_ALL_USAGES sy-vline
WA_RCGTPLHIOT_STR-MARKFLG sy-vline
WA_RCGTPLHIOT_STR-SELEFLG sy-vline
WA_RCGTPLHIOT_STR-LINENO sy-vline
WA_RCGTPLHIOT_STR-LINEMOD sy-vline
WA_RCGTPLHIOT_STR-CHCOFLG sy-vline
WA_RCGTPLHIOT_STR-LOCKMOD sy-vline
WA_RCGTPLHIOT_STR-INTRFLG sy-vline
WA_RCGTPLHIOT_STR-RECN_COLLISION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.