ABAP Select data from SAP table RCF_S_TRM_CAND_HITLIST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCF_S_TRM_CAND_HITLIST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCF_S_TRM_CAND_HITLIST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RCF_S_TRM_CAND_HITLIST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RCF_S_TRM_CAND_HITLIST TYPE STANDARD TABLE OF RCF_S_TRM_CAND_HITLIST,
      WA_RCF_S_TRM_CAND_HITLIST TYPE RCF_S_TRM_CAND_HITLIST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RCF_S_TRM_CAND_HITLIST> TYPE RCF_S_TRM_CAND_HITLIST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RCF_S_TRM_CAND_HITLIST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RCF_S_TRM_CAND_HITLIST
  INTO TABLE IT_RCF_S_TRM_CAND_HITLIST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RCF_S_TRM_CAND_HITLIST
*  INTO TABLE @DATA(IT_RCF_S_TRM_CAND_HITLIST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RCF_S_TRM_CAND_HITLIST INDEX 1 INTO DATA(WA_RCF_S_TRM_CAND_HITLIST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RCF_S_TRM_CAND_HITLIST ASSIGNING <RCF_S_TRM_CAND_HITLIST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCF_S_TRM_CAND_HITLIST>-CAND_HROBJECT = 1.
<RCF_S_TRM_CAND_HITLIST>-PLVAR = 1.
<RCF_S_TRM_CAND_HITLIST>-OTYPE = 1.
<RCF_S_TRM_CAND_HITLIST>-OBJID = 1.
<RCF_S_TRM_CAND_HITLIST>-CAND_FULLNAME = 1.
ENDLOOP.

LOOP AT IT_RCF_S_TRM_CAND_HITLIST INTO WA_RCF_S_TRM_CAND_HITLIST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RCF_S_TRM_CAND_HITLIST-IS_EMPLOYEE, sy-vline,
WA_RCF_S_TRM_CAND_HITLIST-EMPLOYEEID, sy-vline,
WA_RCF_S_TRM_CAND_HITLIST-CAND_NAME_ADDRESS, sy-vline,
WA_RCF_S_TRM_CAND_HITLIST-EMAIL, sy-vline,
WA_RCF_S_TRM_CAND_HITLIST-LAST_LOGIN, sy-vline,
WA_RCF_S_TRM_CAND_HITLIST-EMPLOYER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCF_S_TRM_CAND_HITLIST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCF_S_TRM_CAND_HITLIST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCF_S_TRM_CAND_HITLIST INTO WA_RCF_S_TRM_CAND_HITLIST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit SXIDN, internal->external for field EMAIL CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_RCF_S_TRM_CAND_HITLIST-EMAIL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCF_S_TRM_CAND_HITLIST-EMAIL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCF_S_TRM_CAND_HITLIST_STR,
CAND_HROBJECT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
CAND_FULLNAME TYPE STRING,
IS_EMPLOYEE TYPE STRING,
EMPLOYEEID TYPE STRING,
CAND_NAME_ADDRESS TYPE STRING,
EMAIL TYPE STRING,
LAST_LOGIN TYPE STRING,
EMPLOYER TYPE STRING,
DEGREE TYPE STRING,
RANKV TYPE STRING,
CAND_CLASSIF TYPE STRING,
CAND_CLASSIF_TEXT TYPE STRING,
TGROUP TYPE STRING,
TGROUP_TXT TYPE STRING,
CAND_STATUS TYPE STRING,
CAND_STATUS_TXT TYPE STRING,
EXCERPT TYPE STRING,
URL TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCF_S_TRM_CAND_HITLIST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-CAND_HROBJECT sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-PLVAR sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-OTYPE sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-OBJID sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-CAND_FULLNAME sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-IS_EMPLOYEE sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-EMPLOYEEID sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-CAND_NAME_ADDRESS sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-EMAIL sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-LAST_LOGIN sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-EMPLOYER sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-DEGREE sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-RANKV sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-CAND_CLASSIF sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-CAND_CLASSIF_TEXT sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-TGROUP sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-TGROUP_TXT sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-CAND_STATUS sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-CAND_STATUS_TXT sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-EXCERPT sy-vline
WA_RCF_S_TRM_CAND_HITLIST_STR-URL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.