ABAP Select data from SAP table RCF_S_PD_ACT_GENERAL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCF_S_PD_ACT_GENERAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCF_S_PD_ACT_GENERAL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RCF_S_PD_ACT_GENERAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RCF_S_PD_ACT_GENERAL TYPE STANDARD TABLE OF RCF_S_PD_ACT_GENERAL,
      WA_RCF_S_PD_ACT_GENERAL TYPE RCF_S_PD_ACT_GENERAL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RCF_S_PD_ACT_GENERAL> TYPE RCF_S_PD_ACT_GENERAL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RCF_S_PD_ACT_GENERAL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RCF_S_PD_ACT_GENERAL
  INTO TABLE IT_RCF_S_PD_ACT_GENERAL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RCF_S_PD_ACT_GENERAL
*  INTO TABLE @DATA(IT_RCF_S_PD_ACT_GENERAL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RCF_S_PD_ACT_GENERAL INDEX 1 INTO DATA(WA_RCF_S_PD_ACT_GENERAL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RCF_S_PD_ACT_GENERAL ASSIGNING <RCF_S_PD_ACT_GENERAL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCF_S_PD_ACT_GENERAL>-MANDT = 1.
<RCF_S_PD_ACT_GENERAL>-PLVAR = 1.
<RCF_S_PD_ACT_GENERAL>-OTYPE = 1.
<RCF_S_PD_ACT_GENERAL>-OBJID = 1.
<RCF_S_PD_ACT_GENERAL>-SUBTY = 1.
ENDLOOP.

LOOP AT IT_RCF_S_PD_ACT_GENERAL INTO WA_RCF_S_PD_ACT_GENERAL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RCF_S_PD_ACT_GENERAL-ISTAT, sy-vline,
WA_RCF_S_PD_ACT_GENERAL-BEGDA, sy-vline,
WA_RCF_S_PD_ACT_GENERAL-ENDDA, sy-vline,
WA_RCF_S_PD_ACT_GENERAL-VARYF, sy-vline,
WA_RCF_S_PD_ACT_GENERAL-SEQNR, sy-vline,
WA_RCF_S_PD_ACT_GENERAL-ACT_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCF_S_PD_ACT_GENERAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCF_S_PD_ACT_GENERAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCF_S_PD_ACT_GENERAL INTO WA_RCF_S_PD_ACT_GENERAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCF_S_PD_ACT_GENERAL_STR,
MANDT TYPE STRING,
PLVAR TYPE STRING,
OTYPE TYPE STRING,
OBJID TYPE STRING,
SUBTY TYPE STRING,
ISTAT TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
VARYF TYPE STRING,
SEQNR TYPE STRING,
ACT_TYPE TYPE STRING,
ACT_GUID TYPE STRING,
STATUS TYPE STRING,
DUE_DATE TYPE STRING,
RES_SCLAS TYPE STRING,
RES_SOBID TYPE STRING,
NOTE TYPE STRING,
ACT_CAT TYPE STRING,
DATE_EXECUTED TYPE STRING,
EXECUTER TYPE STRING,
ACT_PROC TYPE STRING,
SUBAREA TYPE STRING,
TG_ID TYPE STRING,
LAST_CHANGED TYPE STRING,
CREATOR TYPE STRING,
CREATED_ON TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCF_S_PD_ACT_GENERAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-MANDT sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-PLVAR sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-OTYPE sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-OBJID sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-SUBTY sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-ISTAT sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-BEGDA sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-ENDDA sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-VARYF sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-SEQNR sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-ACT_TYPE sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-ACT_GUID sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-STATUS sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-DUE_DATE sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-RES_SCLAS sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-RES_SOBID sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-NOTE sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-ACT_CAT sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-DATE_EXECUTED sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-EXECUTER sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-ACT_PROC sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-SUBAREA sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-TG_ID sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-LAST_CHANGED sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-CREATOR sy-vline
WA_RCF_S_PD_ACT_GENERAL_STR-CREATED_ON sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.