ABAP Select data from SAP table RCCFS_LOG_ENTRY into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCCFS_LOG_ENTRY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCCFS_LOG_ENTRY. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RCCFS_LOG_ENTRY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RCCFS_LOG_ENTRY TYPE STANDARD TABLE OF RCCFS_LOG_ENTRY,
      WA_RCCFS_LOG_ENTRY TYPE RCCFS_LOG_ENTRY,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RCCFS_LOG_ENTRY> TYPE RCCFS_LOG_ENTRY.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RCCFS_LOG_ENTRY.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RCCFS_LOG_ENTRY
  INTO TABLE IT_RCCFS_LOG_ENTRY.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RCCFS_LOG_ENTRY
*  INTO TABLE @DATA(IT_RCCFS_LOG_ENTRY2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RCCFS_LOG_ENTRY INDEX 1 INTO DATA(WA_RCCFS_LOG_ENTRY2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RCCFS_LOG_ENTRY ASSIGNING <RCCFS_LOG_ENTRY>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCCFS_LOG_ENTRY>-HANDLE = 1.
<RCCFS_LOG_ENTRY>-ID = 1.
<RCCFS_LOG_ENTRY>-SLOT_NO = 1.
<RCCFS_LOG_ENTRY>-APP = 1.
<RCCFS_LOG_ENTRY>-USERNAME = 1.
ENDLOOP.

LOOP AT IT_RCCFS_LOG_ENTRY INTO WA_RCCFS_LOG_ENTRY.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RCCFS_LOG_ENTRY-STARTDATE, sy-vline,
WA_RCCFS_LOG_ENTRY-STARTTIME, sy-vline,
WA_RCCFS_LOG_ENTRY-APPL_LOGHNDL, sy-vline,
WA_RCCFS_LOG_ENTRY-ENGINE_PROFILE, sy-vline,
WA_RCCFS_LOG_ENTRY-ENGINE_CUSTID, sy-vline,
WA_RCCFS_LOG_ENTRY-STATUS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCCFS_LOG_ENTRY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCCFS_LOG_ENTRY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCCFS_LOG_ENTRY INTO WA_RCCFS_LOG_ENTRY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCCFS_LOG_ENTRY_STR,
HANDLE TYPE STRING,
ID TYPE STRING,
SLOT_NO TYPE STRING,
APP TYPE STRING,
USERNAME TYPE STRING,
STARTDATE TYPE STRING,
STARTTIME TYPE STRING,
APPL_LOGHNDL TYPE STRING,
ENGINE_PROFILE TYPE STRING,
ENGINE_CUSTID TYPE STRING,
STATUS TYPE STRING,
EXT_1 TYPE STRING,
EXT_2 TYPE STRING,
EXT_3 TYPE STRING,
GRID_LOGID TYPE STRING,
CALLBACK_CLASS TYPE STRING,
ENGINE_TIMESTAMP TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCCFS_LOG_ENTRY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCCFS_LOG_ENTRY_STR-HANDLE sy-vline
WA_RCCFS_LOG_ENTRY_STR-ID sy-vline
WA_RCCFS_LOG_ENTRY_STR-SLOT_NO sy-vline
WA_RCCFS_LOG_ENTRY_STR-APP sy-vline
WA_RCCFS_LOG_ENTRY_STR-USERNAME sy-vline
WA_RCCFS_LOG_ENTRY_STR-STARTDATE sy-vline
WA_RCCFS_LOG_ENTRY_STR-STARTTIME sy-vline
WA_RCCFS_LOG_ENTRY_STR-APPL_LOGHNDL sy-vline
WA_RCCFS_LOG_ENTRY_STR-ENGINE_PROFILE sy-vline
WA_RCCFS_LOG_ENTRY_STR-ENGINE_CUSTID sy-vline
WA_RCCFS_LOG_ENTRY_STR-STATUS sy-vline
WA_RCCFS_LOG_ENTRY_STR-EXT_1 sy-vline
WA_RCCFS_LOG_ENTRY_STR-EXT_2 sy-vline
WA_RCCFS_LOG_ENTRY_STR-EXT_3 sy-vline
WA_RCCFS_LOG_ENTRY_STR-GRID_LOGID sy-vline
WA_RCCFS_LOG_ENTRY_STR-CALLBACK_CLASS sy-vline
WA_RCCFS_LOG_ENTRY_STR-ENGINE_TIMESTAMP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.