ABAP Select data from SAP table RCCBUSVOLSELCRI into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCCBUSVOLSELCRI table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCCBUSVOLSELCRI. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RCCBUSVOLSELCRI table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RCCBUSVOLSELCRI TYPE STANDARD TABLE OF RCCBUSVOLSELCRI,
      WA_RCCBUSVOLSELCRI TYPE RCCBUSVOLSELCRI,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RCCBUSVOLSELCRI> TYPE RCCBUSVOLSELCRI.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RCCBUSVOLSELCRI.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RCCBUSVOLSELCRI
  INTO TABLE IT_RCCBUSVOLSELCRI.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RCCBUSVOLSELCRI
*  INTO TABLE @DATA(IT_RCCBUSVOLSELCRI2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RCCBUSVOLSELCRI INDEX 1 INTO DATA(WA_RCCBUSVOLSELCRI2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RCCBUSVOLSELCRI ASSIGNING <RCCBUSVOLSELCRI>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCCBUSVOLSELCRI>-MANDT = 1.
<RCCBUSVOLSELCRI>-CONDITIONCONTRACT = 1.
<RCCBUSVOLSELCRI>-CNDNCONTRBUSVOLUUID = 1.
<RCCBUSVOLSELCRI>-BUSVOLFIELDCOMBNTYPE = 1.
<RCCBUSVOLSELCRI>-BUSVOLFLDCOMBNGROUP = 1.
ENDLOOP.

LOOP AT IT_RCCBUSVOLSELCRI INTO WA_RCCBUSVOLSELCRI.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RCCBUSVOLSELCRI-CNDNCONTRBUSVOLSIGN, sy-vline,
WA_RCCBUSVOLSELCRI-CNDNCONTRSUPPLIER, sy-vline,
WA_RCCBUSVOLSELCRI-CNDNCONTRCUSTOMER, sy-vline,
WA_RCCBUSVOLSELCRI-BUSVOLSELECTIONGROUP, sy-vline,
WA_RCCBUSVOLSELCRI-CNDNCONTRBUSVOLVALIDFROM, sy-vline,
WA_RCCBUSVOLSELCRI-CNDNCONTRBUSVOLVALIDTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCCBUSVOLSELCRI you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCCBUSVOLSELCRI TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCCBUSVOLSELCRI INTO WA_RCCBUSVOLSELCRI. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field CONDITIONCONTRACT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-CONDITIONCONTRACT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-CONDITIONCONTRACT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CNDNCONTRSUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-CNDNCONTRSUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-CNDNCONTRSUPPLIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CNDNCONTRCUSTOMER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-CNDNCONTRCUSTOMER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-CNDNCONTRCUSTOMER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SUPPLIER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-SUPPLIER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-SUPPLIER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CUSTOMER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-CUSTOMER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-CUSTOMER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PRODUCT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-PRODUCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-PRODUCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CNDNCONTRCUSTOMERLIST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-CNDNCONTRCUSTOMERLIST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-CNDNCONTRCUSTOMERLIST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CNDNCONTRSUPPLIERLIST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-CNDNCONTRSUPPLIERLIST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-CNDNCONTRSUPPLIERLIST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CNDNCONTRPLANTLIST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-CNDNCONTRPLANTLIST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-CNDNCONTRPLANTLIST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CUSTOMERHIERARCHY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-CUSTOMERHIERARCHY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-CUSTOMERHIERARCHY.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CNDNCONTRBUSVOLLIST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-CNDNCONTRBUSVOLLIST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-CNDNCONTRBUSVOLLIST.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field MANUFACTURER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-MANUFACTURER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-MANUFACTURER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ROYALTYRECIPIENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-ROYALTYRECIPIENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-ROYALTYRECIPIENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field COMMISSIONRECIPIENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-COMMISSIONRECIPIENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-COMMISSIONRECIPIENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SERVICEDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCCBUSVOLSELCRI-SERVICEDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCCBUSVOLSELCRI-SERVICEDOCUMENT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCCBUSVOLSELCRI_STR,
MANDT TYPE STRING,
CONDITIONCONTRACT TYPE STRING,
CNDNCONTRBUSVOLUUID TYPE STRING,
BUSVOLFIELDCOMBNTYPE TYPE STRING,
BUSVOLFLDCOMBNGROUP TYPE STRING,
CNDNCONTRBUSVOLSIGN TYPE STRING,
CNDNCONTRSUPPLIER TYPE STRING,
CNDNCONTRCUSTOMER TYPE STRING,
BUSVOLSELECTIONGROUP TYPE STRING,
CNDNCONTRBUSVOLVALIDFROM TYPE STRING,
CNDNCONTRBUSVOLVALIDTO TYPE STRING,
SUPPLIER TYPE STRING,
CUSTOMER TYPE STRING,
PURCHASINGORGANIZATION TYPE STRING,
PURCHASINGGROUP TYPE STRING,
SALESORGANIZATION TYPE STRING,
DISTRIBUTIONCHANNEL TYPE STRING,
DIVISION TYPE STRING,
COMPANYCODE TYPE STRING,
PLANT TYPE STRING,
SUPPLIERSUBRANGE TYPE STRING,
PRODUCTGROUP TYPE STRING,
PRODUCT TYPE STRING,
CNDNCONTRCUSTOMERLIST TYPE STRING,
CNDNCONTRSUPPLIERLIST TYPE STRING,
CNDNCONTRPLANTLIST TYPE STRING,
CUSTOMERHIERARCHY TYPE STRING,
PRODUCTHIERARCHY TYPE STRING,
SALESSPCFCPRODUCTGROUP1 TYPE STRING,
SALESSPCFCPRODUCTGROUP2 TYPE STRING,
SALESSPCFCPRODUCTGROUP3 TYPE STRING,
SALESSPCFCPRODUCTGROUP4 TYPE STRING,
SALESSPCFCPRODUCTGROUP5 TYPE STRING,
CNDNCONTRBUSVOLLIST TYPE STRING,
PRODUCTTYPE TYPE STRING,
SALESORDERREASON TYPE STRING,
MANUFACTURER TYPE STRING,
ROYALTYRECIPIENT TYPE STRING,
COMMISSIONRECIPIENT TYPE STRING,
SERVICEDOCUMENTTYPE TYPE STRING,
SERVICEDOCUMENT TYPE STRING,
SERVICEDOCUMENTITEM TYPE STRING,
CNDNCONTRSOURCEBUSVOLUUID TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCCBUSVOLSELCRI_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCCBUSVOLSELCRI_STR-MANDT sy-vline
WA_RCCBUSVOLSELCRI_STR-CONDITIONCONTRACT sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRBUSVOLUUID sy-vline
WA_RCCBUSVOLSELCRI_STR-BUSVOLFIELDCOMBNTYPE sy-vline
WA_RCCBUSVOLSELCRI_STR-BUSVOLFLDCOMBNGROUP sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRBUSVOLSIGN sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRSUPPLIER sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRCUSTOMER sy-vline
WA_RCCBUSVOLSELCRI_STR-BUSVOLSELECTIONGROUP sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRBUSVOLVALIDFROM sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRBUSVOLVALIDTO sy-vline
WA_RCCBUSVOLSELCRI_STR-SUPPLIER sy-vline
WA_RCCBUSVOLSELCRI_STR-CUSTOMER sy-vline
WA_RCCBUSVOLSELCRI_STR-PURCHASINGORGANIZATION sy-vline
WA_RCCBUSVOLSELCRI_STR-PURCHASINGGROUP sy-vline
WA_RCCBUSVOLSELCRI_STR-SALESORGANIZATION sy-vline
WA_RCCBUSVOLSELCRI_STR-DISTRIBUTIONCHANNEL sy-vline
WA_RCCBUSVOLSELCRI_STR-DIVISION sy-vline
WA_RCCBUSVOLSELCRI_STR-COMPANYCODE sy-vline
WA_RCCBUSVOLSELCRI_STR-PLANT sy-vline
WA_RCCBUSVOLSELCRI_STR-SUPPLIERSUBRANGE sy-vline
WA_RCCBUSVOLSELCRI_STR-PRODUCTGROUP sy-vline
WA_RCCBUSVOLSELCRI_STR-PRODUCT sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRCUSTOMERLIST sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRSUPPLIERLIST sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRPLANTLIST sy-vline
WA_RCCBUSVOLSELCRI_STR-CUSTOMERHIERARCHY sy-vline
WA_RCCBUSVOLSELCRI_STR-PRODUCTHIERARCHY sy-vline
WA_RCCBUSVOLSELCRI_STR-SALESSPCFCPRODUCTGROUP1 sy-vline
WA_RCCBUSVOLSELCRI_STR-SALESSPCFCPRODUCTGROUP2 sy-vline
WA_RCCBUSVOLSELCRI_STR-SALESSPCFCPRODUCTGROUP3 sy-vline
WA_RCCBUSVOLSELCRI_STR-SALESSPCFCPRODUCTGROUP4 sy-vline
WA_RCCBUSVOLSELCRI_STR-SALESSPCFCPRODUCTGROUP5 sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRBUSVOLLIST sy-vline
WA_RCCBUSVOLSELCRI_STR-PRODUCTTYPE sy-vline
WA_RCCBUSVOLSELCRI_STR-SALESORDERREASON sy-vline
WA_RCCBUSVOLSELCRI_STR-MANUFACTURER sy-vline
WA_RCCBUSVOLSELCRI_STR-ROYALTYRECIPIENT sy-vline
WA_RCCBUSVOLSELCRI_STR-COMMISSIONRECIPIENT sy-vline
WA_RCCBUSVOLSELCRI_STR-SERVICEDOCUMENTTYPE sy-vline
WA_RCCBUSVOLSELCRI_STR-SERVICEDOCUMENT sy-vline
WA_RCCBUSVOLSELCRI_STR-SERVICEDOCUMENTITEM sy-vline
WA_RCCBUSVOLSELCRI_STR-CNDNCONTRSOURCEBUSVOLUUID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.