ABAP Select data from SAP table RCBUNCARRIOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCBUNCARRIOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCBUNCARRIOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RCBUNCARRIOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RCBUNCARRIOT TYPE STANDARD TABLE OF RCBUNCARRIOT,
      WA_RCBUNCARRIOT TYPE RCBUNCARRIOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RCBUNCARRIOT> TYPE RCBUNCARRIOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RCBUNCARRIOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RCBUNCARRIOT
  INTO TABLE IT_RCBUNCARRIOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RCBUNCARRIOT
*  INTO TABLE @DATA(IT_RCBUNCARRIOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RCBUNCARRIOT INDEX 1 INTO DATA(WA_RCBUNCARRIOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RCBUNCARRIOT ASSIGNING <RCBUNCARRIOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCBUNCARRIOT>-MARKFLG = 1.
<RCBUNCARRIOT>-SELEFLG = 1.
<RCBUNCARRIOT>-LINENO = 1.
<RCBUNCARRIOT>-LINEMOD = 1.
<RCBUNCARRIOT>-CHCOFLG = 1.
ENDLOOP.

LOOP AT IT_RCBUNCARRIOT INTO WA_RCBUNCARRIOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RCBUNCARRIOT-LOCKMOD, sy-vline,
WA_RCBUNCARRIOT-INTRFLG, sy-vline,
WA_RCBUNCARRIOT-MANDT, sy-vline,
WA_RCBUNCARRIOT-RECN, sy-vline,
WA_RCBUNCARRIOT-ACTN, sy-vline,
WA_RCBUNCARRIOT-VALFR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCBUNCARRIOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCBUNCARRIOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCBUNCARRIOT INTO WA_RCBUNCARRIOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNCARRIOT-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNCARRIOT-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNCARRIOT-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNCARRIOT-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNCARRIOT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNCARRIOT-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNCARRIOT-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNCARRIOT-OWNID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNCARRIOT-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNCARRIOT-RECNROOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNMST CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBUNCARRIOT-RECNMST IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBUNCARRIOT-RECNMST.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCBUNCARRIOT_STR,
MARKFLG TYPE STRING,
SELEFLG TYPE STRING,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
CHCOFLG TYPE STRING,
LOCKMOD TYPE STRING,
INTRFLG TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
RECNMST TYPE STRING,
DPOT TYPE STRING,
SPPROV_PHRKEY TYPE STRING,
SP_PRINT_PHRKEY TYPE STRING,
MIX_PACK_PHRKEY TYPE STRING,
SEGREGAT_PHRKEY TYPE STRING,
PACKAGES_PHRKEY TYPE STRING,
BULK_PHRKEY TYPE STRING,
HANDLING_PHRKEY TYPE STRING,
OPERATION_PHRKEY TYPE STRING,
VEHICLE_PHRKEY TYPE STRING,
LWDG TYPE STRING,
DGCL TYPE STRING,
DPOTD TYPE STRING,
LDBC TYPE STRING,
LDBCD TYPE STRING,
PGRO TYPE STRING,
SPPROV_C TYPE STRING,
SPPROV_D TYPE STRING,
SP_PRINT_C TYPE STRING,
SP_PRINT_D TYPE STRING,
MIX_PACK_C TYPE STRING,
MIX_PACK_D TYPE STRING,
SEGREGAT_C TYPE STRING,
SEGREGAT_D TYPE STRING,
PACKAGES_C TYPE STRING,
PACKAGES_D TYPE STRING,
BULK_C TYPE STRING,
BULK_D TYPE STRING,
HANDLING_C TYPE STRING,
HANDLING_D TYPE STRING,
OPERATION_C TYPE STRING,
OPERATION_D TYPE STRING,
VEHICLE_C TYPE STRING,
VEHICLE_D TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCBUNCARRIOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCBUNCARRIOT_STR-MARKFLG sy-vline
WA_RCBUNCARRIOT_STR-SELEFLG sy-vline
WA_RCBUNCARRIOT_STR-LINENO sy-vline
WA_RCBUNCARRIOT_STR-LINEMOD sy-vline
WA_RCBUNCARRIOT_STR-CHCOFLG sy-vline
WA_RCBUNCARRIOT_STR-LOCKMOD sy-vline
WA_RCBUNCARRIOT_STR-INTRFLG sy-vline
WA_RCBUNCARRIOT_STR-MANDT sy-vline
WA_RCBUNCARRIOT_STR-RECN sy-vline
WA_RCBUNCARRIOT_STR-ACTN sy-vline
WA_RCBUNCARRIOT_STR-VALFR sy-vline
WA_RCBUNCARRIOT_STR-VALTO sy-vline
WA_RCBUNCARRIOT_STR-AENNR sy-vline
WA_RCBUNCARRIOT_STR-DELFLG sy-vline
WA_RCBUNCARRIOT_STR-PARKFLG sy-vline
WA_RCBUNCARRIOT_STR-CRDAT sy-vline
WA_RCBUNCARRIOT_STR-CRNAM sy-vline
WA_RCBUNCARRIOT_STR-UPDDAT sy-vline
WA_RCBUNCARRIOT_STR-UPDNAM sy-vline
WA_RCBUNCARRIOT_STR-SRSID sy-vline
WA_RCBUNCARRIOT_STR-OWNID sy-vline
WA_RCBUNCARRIOT_STR-RECNROOT sy-vline
WA_RCBUNCARRIOT_STR-RECNMST sy-vline
WA_RCBUNCARRIOT_STR-DPOT sy-vline
WA_RCBUNCARRIOT_STR-SPPROV_PHRKEY sy-vline
WA_RCBUNCARRIOT_STR-SP_PRINT_PHRKEY sy-vline
WA_RCBUNCARRIOT_STR-MIX_PACK_PHRKEY sy-vline
WA_RCBUNCARRIOT_STR-SEGREGAT_PHRKEY sy-vline
WA_RCBUNCARRIOT_STR-PACKAGES_PHRKEY sy-vline
WA_RCBUNCARRIOT_STR-BULK_PHRKEY sy-vline
WA_RCBUNCARRIOT_STR-HANDLING_PHRKEY sy-vline
WA_RCBUNCARRIOT_STR-OPERATION_PHRKEY sy-vline
WA_RCBUNCARRIOT_STR-VEHICLE_PHRKEY sy-vline
WA_RCBUNCARRIOT_STR-LWDG sy-vline
WA_RCBUNCARRIOT_STR-DGCL sy-vline
WA_RCBUNCARRIOT_STR-DPOTD sy-vline
WA_RCBUNCARRIOT_STR-LDBC sy-vline
WA_RCBUNCARRIOT_STR-LDBCD sy-vline
WA_RCBUNCARRIOT_STR-PGRO sy-vline
WA_RCBUNCARRIOT_STR-SPPROV_C sy-vline
WA_RCBUNCARRIOT_STR-SPPROV_D sy-vline
WA_RCBUNCARRIOT_STR-SP_PRINT_C sy-vline
WA_RCBUNCARRIOT_STR-SP_PRINT_D sy-vline
WA_RCBUNCARRIOT_STR-MIX_PACK_C sy-vline
WA_RCBUNCARRIOT_STR-MIX_PACK_D sy-vline
WA_RCBUNCARRIOT_STR-SEGREGAT_C sy-vline
WA_RCBUNCARRIOT_STR-SEGREGAT_D sy-vline
WA_RCBUNCARRIOT_STR-PACKAGES_C sy-vline
WA_RCBUNCARRIOT_STR-PACKAGES_D sy-vline
WA_RCBUNCARRIOT_STR-BULK_C sy-vline
WA_RCBUNCARRIOT_STR-BULK_D sy-vline
WA_RCBUNCARRIOT_STR-HANDLING_C sy-vline
WA_RCBUNCARRIOT_STR-HANDLING_D sy-vline
WA_RCBUNCARRIOT_STR-OPERATION_C sy-vline
WA_RCBUNCARRIOT_STR-OPERATION_D sy-vline
WA_RCBUNCARRIOT_STR-VEHICLE_C sy-vline
WA_RCBUNCARRIOT_STR-VEHICLE_D sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.