ABAP Select data from SAP table RCBDUDGRELIOT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RCBDUDGRELIOT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RCBDUDGRELIOT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RCBDUDGRELIOT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RCBDUDGRELIOT TYPE STANDARD TABLE OF RCBDUDGRELIOT,
      WA_RCBDUDGRELIOT TYPE RCBDUDGRELIOT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RCBDUDGRELIOT> TYPE RCBDUDGRELIOT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RCBDUDGRELIOT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RCBDUDGRELIOT
  INTO TABLE IT_RCBDUDGRELIOT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RCBDUDGRELIOT
*  INTO TABLE @DATA(IT_RCBDUDGRELIOT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RCBDUDGRELIOT INDEX 1 INTO DATA(WA_RCBDUDGRELIOT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RCBDUDGRELIOT ASSIGNING <RCBDUDGRELIOT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RCBDUDGRELIOT>-MARKFLG = 1.
<RCBDUDGRELIOT>-SELEFLG = 1.
<RCBDUDGRELIOT>-LINENO = 1.
<RCBDUDGRELIOT>-LINEMOD = 1.
<RCBDUDGRELIOT>-CHCOFLG = 1.
ENDLOOP.

LOOP AT IT_RCBDUDGRELIOT INTO WA_RCBDUDGRELIOT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RCBDUDGRELIOT-LOCKMOD, sy-vline,
WA_RCBDUDGRELIOT-INTRFLG, sy-vline,
WA_RCBDUDGRELIOT-MANDT, sy-vline,
WA_RCBDUDGRELIOT-RECN, sy-vline,
WA_RCBDUDGRELIOT-ACTN, sy-vline,
WA_RCBDUDGRELIOT-VALFR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RCBDUDGRELIOT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RCBDUDGRELIOT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RCBDUDGRELIOT INTO WA_RCBDUDGRELIOT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RECN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-RECN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-RECN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ACTN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-ACTN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-ACTN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field OWNID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-OWNID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-OWNID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECNROOT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-RECNROOT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-RECNROOT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PACKAGE_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-PACKAGE_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-PACKAGE_MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field U_QUANT_OUT_PACK CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-U_QUANT_OUT_PACK IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-U_QUANT_OUT_PACK.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECN_SUB CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-RECN_SUB IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-RECN_SUB.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RECN_CLASS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-RECN_CLASS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-RECN_CLASS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field U_MAX_GROSS_WGHT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-U_MAX_GROSS_WGHT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-U_MAX_GROSS_WGHT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field EXPL_NET_DYN_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-EXPL_NET_DYN_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-EXPL_NET_DYN_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MAX_ACT_SGL_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-MAX_ACT_SGL_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-MAX_ACT_SGL_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MAX_ACT_PACK_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-MAX_ACT_PACK_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-MAX_ACT_PACK_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MAX_NEM_U CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-MAX_NEM_U IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-MAX_NEM_U.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR_REPLACE CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-MATNR_REPLACE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-MATNR_REPLACE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPEC1, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-SUBID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SPEC1, internal->external for field SUBID_CLASS CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_RCBDUDGRELIOT-SUBID_CLASS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_RCBDUDGRELIOT-SUBID_CLASS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RCBDUDGRELIOT_STR,
MARKFLG TYPE STRING,
SELEFLG TYPE STRING,
LINENO TYPE STRING,
LINEMOD TYPE STRING,
CHCOFLG TYPE STRING,
LOCKMOD TYPE STRING,
INTRFLG TYPE STRING,
MANDT TYPE STRING,
RECN TYPE STRING,
ACTN TYPE STRING,
VALFR TYPE STRING,
VALTO TYPE STRING,
AENNR TYPE STRING,
DELFLG TYPE STRING,
PARKFLG TYPE STRING,
CRDAT TYPE STRING,
CRNAM TYPE STRING,
UPDDAT TYPE STRING,
UPDNAM TYPE STRING,
SRSID TYPE STRING,
OWNID TYPE STRING,
RECNROOT TYPE STRING,
MATNR TYPE STRING,
LWDG TYPE STRING,
PACKAGE_MATNR TYPE STRING,
DAOR TYPE STRING,
PRIO_ALTERN TYPE STRING,
FLG_RELEASED TYPE STRING,
FLG_TRANS_PERM TYPE STRING,
FLG_NO_DG TYPE STRING,
FLG_LQ TYPE STRING,
FLG_RQ TYPE STRING,
INSTR_ENCL TYPE STRING,
FLG_SINGLE_PACK TYPE STRING,
PACOD TYPE STRING,
QUANT_OUT_PACK TYPE STRING,
U_QUANT_OUT_PACK TYPE STRING,
PACK_NOTE TYPE STRING,
RECN_SUB TYPE STRING,
RECN_CLASS TYPE STRING,
FLG_CC TYPE STRING,
FLG_PACKED TYPE STRING,
TRANSPORT_TYPE TYPE STRING,
APPROVAL_CODE TYPE STRING,
MAT_DAMAGED_CL7 TYPE STRING,
MAX_GROSS_WEIGHT TYPE STRING,
U_MAX_GROSS_WGHT TYPE STRING,
SUBID_DG_CLASS TYPE STRING,
EMV_DYN TYPE STRING,
LTSK_DYN TYPE STRING,
EXPL_NET_DYN TYPE STRING,
EXPL_NET_DYN_U TYPE STRING,
MAX_ACT_SGL TYPE STRING,
MAX_ACT_SGL_U TYPE STRING,
ACT_SGL_UNLIMIT TYPE STRING,
MAX_ACT_PACK TYPE STRING,
MAX_ACT_PACK_U TYPE STRING,
ACT_PACK_UNLIMIT TYPE STRING,
EXCEPT_PACK_OPT TYPE STRING,
DG_USE_CASE TYPE STRING,
PRIO_DYNCL TYPE STRING,
MAX_NEM TYPE STRING,
MAX_NEM_U TYPE STRING,
DUMMY_RCBDUDGREL TYPE STRING,
FLG_EQ TYPE STRING,
DGREL_TRANSIND01 TYPE STRING,
DGREL_TRANSIND02 TYPE STRING,
DGREL_TRANSIND03 TYPE STRING,
DGREL_TRANSIND04 TYPE STRING,
DGREL_TRANSIND05 TYPE STRING,
DGREL_TRANSIND06 TYPE STRING,
DGREL_TRANSIND07 TYPE STRING,
DGREL_TRANSIND08 TYPE STRING,
MATNR_REPLACE TYPE STRING,
SCREENFLAG TYPE STRING,
SUBID TYPE STRING,
SUBID_CLASS TYPE STRING,
PACKCODE_D TYPE STRING,
PACKDC TYPE STRING,
PACKTYPE TYPE STRING,
TRANSPORT_TYPE_D TYPE STRING,
PACK_NOTE_D TYPE STRING,
PACKAGE_MAKTX TYPE STRING,
TRANSIND_DESC_01 TYPE STRING,
TRANSIND_DESC_02 TYPE STRING,
TRANSIND_DESC_03 TYPE STRING,
TRANSIND_DESC_04 TYPE STRING,
TRANSIND_DESC_05 TYPE STRING,
TRANSIND_DESC_06 TYPE STRING,
TRANSIND_DESC_07 TYPE STRING,
TRANSIND_DESC_08 TYPE STRING,END OF T_EKKO_STR. DATA: WA_RCBDUDGRELIOT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RCBDUDGRELIOT_STR-MARKFLG sy-vline
WA_RCBDUDGRELIOT_STR-SELEFLG sy-vline
WA_RCBDUDGRELIOT_STR-LINENO sy-vline
WA_RCBDUDGRELIOT_STR-LINEMOD sy-vline
WA_RCBDUDGRELIOT_STR-CHCOFLG sy-vline
WA_RCBDUDGRELIOT_STR-LOCKMOD sy-vline
WA_RCBDUDGRELIOT_STR-INTRFLG sy-vline
WA_RCBDUDGRELIOT_STR-MANDT sy-vline
WA_RCBDUDGRELIOT_STR-RECN sy-vline
WA_RCBDUDGRELIOT_STR-ACTN sy-vline
WA_RCBDUDGRELIOT_STR-VALFR sy-vline
WA_RCBDUDGRELIOT_STR-VALTO sy-vline
WA_RCBDUDGRELIOT_STR-AENNR sy-vline
WA_RCBDUDGRELIOT_STR-DELFLG sy-vline
WA_RCBDUDGRELIOT_STR-PARKFLG sy-vline
WA_RCBDUDGRELIOT_STR-CRDAT sy-vline
WA_RCBDUDGRELIOT_STR-CRNAM sy-vline
WA_RCBDUDGRELIOT_STR-UPDDAT sy-vline
WA_RCBDUDGRELIOT_STR-UPDNAM sy-vline
WA_RCBDUDGRELIOT_STR-SRSID sy-vline
WA_RCBDUDGRELIOT_STR-OWNID sy-vline
WA_RCBDUDGRELIOT_STR-RECNROOT sy-vline
WA_RCBDUDGRELIOT_STR-MATNR sy-vline
WA_RCBDUDGRELIOT_STR-LWDG sy-vline
WA_RCBDUDGRELIOT_STR-PACKAGE_MATNR sy-vline
WA_RCBDUDGRELIOT_STR-DAOR sy-vline
WA_RCBDUDGRELIOT_STR-PRIO_ALTERN sy-vline
WA_RCBDUDGRELIOT_STR-FLG_RELEASED sy-vline
WA_RCBDUDGRELIOT_STR-FLG_TRANS_PERM sy-vline
WA_RCBDUDGRELIOT_STR-FLG_NO_DG sy-vline
WA_RCBDUDGRELIOT_STR-FLG_LQ sy-vline
WA_RCBDUDGRELIOT_STR-FLG_RQ sy-vline
WA_RCBDUDGRELIOT_STR-INSTR_ENCL sy-vline
WA_RCBDUDGRELIOT_STR-FLG_SINGLE_PACK sy-vline
WA_RCBDUDGRELIOT_STR-PACOD sy-vline
WA_RCBDUDGRELIOT_STR-QUANT_OUT_PACK sy-vline
WA_RCBDUDGRELIOT_STR-U_QUANT_OUT_PACK sy-vline
WA_RCBDUDGRELIOT_STR-PACK_NOTE sy-vline
WA_RCBDUDGRELIOT_STR-RECN_SUB sy-vline
WA_RCBDUDGRELIOT_STR-RECN_CLASS sy-vline
WA_RCBDUDGRELIOT_STR-FLG_CC sy-vline
WA_RCBDUDGRELIOT_STR-FLG_PACKED sy-vline
WA_RCBDUDGRELIOT_STR-TRANSPORT_TYPE sy-vline
WA_RCBDUDGRELIOT_STR-APPROVAL_CODE sy-vline
WA_RCBDUDGRELIOT_STR-MAT_DAMAGED_CL7 sy-vline
WA_RCBDUDGRELIOT_STR-MAX_GROSS_WEIGHT sy-vline
WA_RCBDUDGRELIOT_STR-U_MAX_GROSS_WGHT sy-vline
WA_RCBDUDGRELIOT_STR-SUBID_DG_CLASS sy-vline
WA_RCBDUDGRELIOT_STR-EMV_DYN sy-vline
WA_RCBDUDGRELIOT_STR-LTSK_DYN sy-vline
WA_RCBDUDGRELIOT_STR-EXPL_NET_DYN sy-vline
WA_RCBDUDGRELIOT_STR-EXPL_NET_DYN_U sy-vline
WA_RCBDUDGRELIOT_STR-MAX_ACT_SGL sy-vline
WA_RCBDUDGRELIOT_STR-MAX_ACT_SGL_U sy-vline
WA_RCBDUDGRELIOT_STR-ACT_SGL_UNLIMIT sy-vline
WA_RCBDUDGRELIOT_STR-MAX_ACT_PACK sy-vline
WA_RCBDUDGRELIOT_STR-MAX_ACT_PACK_U sy-vline
WA_RCBDUDGRELIOT_STR-ACT_PACK_UNLIMIT sy-vline
WA_RCBDUDGRELIOT_STR-EXCEPT_PACK_OPT sy-vline
WA_RCBDUDGRELIOT_STR-DG_USE_CASE sy-vline
WA_RCBDUDGRELIOT_STR-PRIO_DYNCL sy-vline
WA_RCBDUDGRELIOT_STR-MAX_NEM sy-vline
WA_RCBDUDGRELIOT_STR-MAX_NEM_U sy-vline
WA_RCBDUDGRELIOT_STR-DUMMY_RCBDUDGREL sy-vline
WA_RCBDUDGRELIOT_STR-FLG_EQ sy-vline
WA_RCBDUDGRELIOT_STR-DGREL_TRANSIND01 sy-vline
WA_RCBDUDGRELIOT_STR-DGREL_TRANSIND02 sy-vline
WA_RCBDUDGRELIOT_STR-DGREL_TRANSIND03 sy-vline
WA_RCBDUDGRELIOT_STR-DGREL_TRANSIND04 sy-vline
WA_RCBDUDGRELIOT_STR-DGREL_TRANSIND05 sy-vline
WA_RCBDUDGRELIOT_STR-DGREL_TRANSIND06 sy-vline
WA_RCBDUDGRELIOT_STR-DGREL_TRANSIND07 sy-vline
WA_RCBDUDGRELIOT_STR-DGREL_TRANSIND08 sy-vline
WA_RCBDUDGRELIOT_STR-MATNR_REPLACE sy-vline
WA_RCBDUDGRELIOT_STR-SCREENFLAG sy-vline
WA_RCBDUDGRELIOT_STR-SUBID sy-vline
WA_RCBDUDGRELIOT_STR-SUBID_CLASS sy-vline
WA_RCBDUDGRELIOT_STR-PACKCODE_D sy-vline
WA_RCBDUDGRELIOT_STR-PACKDC sy-vline
WA_RCBDUDGRELIOT_STR-PACKTYPE sy-vline
WA_RCBDUDGRELIOT_STR-TRANSPORT_TYPE_D sy-vline
WA_RCBDUDGRELIOT_STR-PACK_NOTE_D sy-vline
WA_RCBDUDGRELIOT_STR-PACKAGE_MAKTX sy-vline
WA_RCBDUDGRELIOT_STR-TRANSIND_DESC_01 sy-vline
WA_RCBDUDGRELIOT_STR-TRANSIND_DESC_02 sy-vline
WA_RCBDUDGRELIOT_STR-TRANSIND_DESC_03 sy-vline
WA_RCBDUDGRELIOT_STR-TRANSIND_DESC_04 sy-vline
WA_RCBDUDGRELIOT_STR-TRANSIND_DESC_05 sy-vline
WA_RCBDUDGRELIOT_STR-TRANSIND_DESC_06 sy-vline
WA_RCBDUDGRELIOT_STR-TRANSIND_DESC_07 sy-vline
WA_RCBDUDGRELIOT_STR-TRANSIND_DESC_08 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.