ABAP Select data from SAP table RC80R into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RC80R table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RC80R. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RC80R table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RC80R TYPE STANDARD TABLE OF RC80R,
      WA_RC80R TYPE RC80R,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RC80R> TYPE RC80R.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RC80R.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RC80R
  INTO TABLE IT_RC80R.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RC80R
*  INTO TABLE @DATA(IT_RC80R2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RC80R INDEX 1 INTO DATA(WA_RC80R2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RC80R ASSIGNING <RC80R>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RC80R>-SIGNSTEP = 1.
<RC80R>-COUNT_STEP = 1.
<RC80R>-COUNT_PRED1 = 1.
<RC80R>-COUNT_PRED2 = 1.
<RC80R>-COUNT_PRED3 = 1.
ENDLOOP.

LOOP AT IT_RC80R INTO WA_RC80R.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RC80R-COUNT_PRED4, sy-vline,
WA_RC80R-COUNT_PRED5, sy-vline,
WA_RC80R-COUNT_PRED6, sy-vline,
WA_RC80R-COUNT_PRED7, sy-vline,
WA_RC80R-COUNT_PRED8, sy-vline,
ENDLOOP. *Add any further fields from structure WA_RC80R you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RC80R TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RC80R INTO WA_RC80R. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RC80R_STR,
SIGNSTEP TYPE STRING,
COUNT_STEP TYPE STRING,
COUNT_PRED1 TYPE STRING,
COUNT_PRED2 TYPE STRING,
COUNT_PRED3 TYPE STRING,
COUNT_PRED4 TYPE STRING,
COUNT_PRED5 TYPE STRING,
COUNT_PRED6 TYPE STRING,
COUNT_PRED7 TYPE STRING,
COUNT_PRED8 TYPE STRING,END OF T_EKKO_STR. DATA: WA_RC80R_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RC80R_STR-SIGNSTEP sy-vline
WA_RC80R_STR-COUNT_STEP sy-vline
WA_RC80R_STR-COUNT_PRED1 sy-vline
WA_RC80R_STR-COUNT_PRED2 sy-vline
WA_RC80R_STR-COUNT_PRED3 sy-vline
WA_RC80R_STR-COUNT_PRED4 sy-vline
WA_RC80R_STR-COUNT_PRED5 sy-vline
WA_RC80R_STR-COUNT_PRED6 sy-vline
WA_RC80R_STR-COUNT_PRED7 sy-vline
WA_RC80R_STR-COUNT_PRED8 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.