ABAP Select data from SAP table RC68H into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP RC68H table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to RC68H. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the RC68H table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_RC68H TYPE STANDARD TABLE OF RC68H,
      WA_RC68H TYPE RC68H,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <RC68H> TYPE RC68H.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_RC68H.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM RC68H
  INTO TABLE IT_RC68H.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM RC68H
*  INTO TABLE @DATA(IT_RC68H2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_RC68H INDEX 1 INTO DATA(WA_RC68H2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_RC68H ASSIGNING <RC68H>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<RC68H>-AKTYP = 1.
<RC68H>-ARBPL = 1.
<RC68H>-ARBPL_UP = 1.
<RC68H>-FLGAV = 1.
<RC68H>-FLG_EXPAND = 1.
ENDLOOP.

LOOP AT IT_RC68H INTO WA_RC68H.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_RC68H-FLG_ROOT, sy-vline,
WA_RC68H-HNAME, sy-vline,
WA_RC68H-KTEXT_H, sy-vline,
WA_RC68H-KTEXT_UP, sy-vline,
WA_RC68H-LEVEL, sy-vline,
WA_RC68H-LEVELS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_RC68H you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_RC68H TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_RC68H INTO WA_RC68H. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_RC68H_STR,
AKTYP TYPE STRING,
ARBPL TYPE STRING,
ARBPL_UP TYPE STRING,
FLGAV TYPE STRING,
FLG_EXPAND TYPE STRING,
FLG_ROOT TYPE STRING,
HNAME TYPE STRING,
KTEXT_H TYPE STRING,
KTEXT_UP TYPE STRING,
LEVEL TYPE STRING,
LEVELS TYPE STRING,
NNAME TYPE STRING,
OBJECT_FCT TYPE STRING,
SELKZ TYPE STRING,
WERKS TYPE STRING,
WERKS_UP TYPE STRING,END OF T_EKKO_STR. DATA: WA_RC68H_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_RC68H_STR-AKTYP sy-vline
WA_RC68H_STR-ARBPL sy-vline
WA_RC68H_STR-ARBPL_UP sy-vline
WA_RC68H_STR-FLGAV sy-vline
WA_RC68H_STR-FLG_EXPAND sy-vline
WA_RC68H_STR-FLG_ROOT sy-vline
WA_RC68H_STR-HNAME sy-vline
WA_RC68H_STR-KTEXT_H sy-vline
WA_RC68H_STR-KTEXT_UP sy-vline
WA_RC68H_STR-LEVEL sy-vline
WA_RC68H_STR-LEVELS sy-vline
WA_RC68H_STR-NNAME sy-vline
WA_RC68H_STR-OBJECT_FCT sy-vline
WA_RC68H_STR-SELKZ sy-vline
WA_RC68H_STR-WERKS sy-vline
WA_RC68H_STR-WERKS_UP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.