ABAP Select data from SAP table QPAPC00 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP QPAPC00 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to QPAPC00. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the QPAPC00 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_QPAPC00 TYPE STANDARD TABLE OF QPAPC00,
      WA_QPAPC00 TYPE QPAPC00,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <QPAPC00> TYPE QPAPC00.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_QPAPC00.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM QPAPC00
  INTO TABLE IT_QPAPC00.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM QPAPC00
*  INTO TABLE @DATA(IT_QPAPC002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_QPAPC00 INDEX 1 INTO DATA(WA_QPAPC002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_QPAPC00 ASSIGNING <QPAPC00>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<QPAPC00>-BUKWRK = 1.
<QPAPC00>-STAREA = 1.
<QPAPC00>-APSTA = 1.
<QPAPC00>-STREA = 1.
<QPAPC00>-APSTV = 1.
ENDLOOP.

LOOP AT IT_QPAPC00 INTO WA_QPAPC00.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_QPAPC00-STREV, sy-vline,
WA_QPAPC00-PETTY, sy-vline,
WA_QPAPC00-PETNO, sy-vline,
WA_QPAPC00-PEMLN, sy-vline,
WA_QPAPC00-PSKET, sy-vline,
WA_QPAPC00-PETFT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_QPAPC00 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_QPAPC00 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_QPAPC00 INTO WA_QPAPC00. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_QPAPC00_STR,
BUKWRK TYPE STRING,
STAREA TYPE STRING,
APSTA TYPE STRING,
STREA TYPE STRING,
APSTV TYPE STRING,
STREV TYPE STRING,
PETTY TYPE STRING,
PETNO TYPE STRING,
PEMLN TYPE STRING,
PSKET TYPE STRING,
PETFT TYPE STRING,
PETCS TYPE STRING,END OF T_EKKO_STR. DATA: WA_QPAPC00_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_QPAPC00_STR-BUKWRK sy-vline
WA_QPAPC00_STR-STAREA sy-vline
WA_QPAPC00_STR-APSTA sy-vline
WA_QPAPC00_STR-STREA sy-vline
WA_QPAPC00_STR-APSTV sy-vline
WA_QPAPC00_STR-STREV sy-vline
WA_QPAPC00_STR-PETTY sy-vline
WA_QPAPC00_STR-PETNO sy-vline
WA_QPAPC00_STR-PEMLN sy-vline
WA_QPAPC00_STR-PSKET sy-vline
WA_QPAPC00_STR-PETFT sy-vline
WA_QPAPC00_STR-PETCS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.