ABAP Select data from SAP table QOD_NOTIF_SELECTION_WITH_ATT_S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP QOD_NOTIF_SELECTION_WITH_ATT_S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to QOD_NOTIF_SELECTION_WITH_ATT_S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the QOD_NOTIF_SELECTION_WITH_ATT_S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_QOD_NOTIF_SELECTION_WITH_ATT_S TYPE STANDARD TABLE OF QOD_NOTIF_SELECTION_WITH_ATT_S,
      WA_QOD_NOTIF_SELECTION_WITH_ATT_S TYPE QOD_NOTIF_SELECTION_WITH_ATT_S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <QOD_NOTIF_SELECTION_WITH_ATT_S> TYPE QOD_NOTIF_SELECTION_WITH_ATT_S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_QOD_NOTIF_SELECTION_WITH_ATT_S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM QOD_NOTIF_SELECTION_WITH_ATT_S
  INTO TABLE IT_QOD_NOTIF_SELECTION_WITH_ATT_S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM QOD_NOTIF_SELECTION_WITH_ATT_S
*  INTO TABLE @DATA(IT_QOD_NOTIF_SELECTION_WITH_ATT_S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_QOD_NOTIF_SELECTION_WITH_ATT_S INDEX 1 INTO DATA(WA_QOD_NOTIF_SELECTION_WITH_ATT_S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_QOD_NOTIF_SELECTION_WITH_ATT_S ASSIGNING <QOD_NOTIF_SELECTION_WITH_ATT_S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<QOD_NOTIF_SELECTION_WITH_ATT_S>-NOTIFICATION_ID = 1.
<QOD_NOTIF_SELECTION_WITH_ATT_S>-SHORT_TEXT = 1.
<QOD_NOTIF_SELECTION_WITH_ATT_S>-REFERENCE_NUMBER = 1.
<QOD_NOTIF_SELECTION_WITH_ATT_S>-LONG_TEXT = 1.
<QOD_NOTIF_SELECTION_WITH_ATT_S>-PRIORITY_TEXT = 1.
ENDLOOP.

LOOP AT IT_QOD_NOTIF_SELECTION_WITH_ATT_S INTO WA_QOD_NOTIF_SELECTION_WITH_ATT_S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_QOD_NOTIF_SELECTION_WITH_ATT_S-CREATED_ON, sy-vline,
WA_QOD_NOTIF_SELECTION_WITH_ATT_S-CREATED_BY, sy-vline,
WA_QOD_NOTIF_SELECTION_WITH_ATT_S-START_TIME, sy-vline,
WA_QOD_NOTIF_SELECTION_WITH_ATT_S-MATNR, sy-vline,
WA_QOD_NOTIF_SELECTION_WITH_ATT_S-MATERIAL_TEXT, sy-vline,
WA_QOD_NOTIF_SELECTION_WITH_ATT_S-NOTIF_CODE_TEXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_QOD_NOTIF_SELECTION_WITH_ATT_S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_QOD_NOTIF_SELECTION_WITH_ATT_S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_QOD_NOTIF_SELECTION_WITH_ATT_S INTO WA_QOD_NOTIF_SELECTION_WITH_ATT_S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field NOTIFICATION_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_QOD_NOTIF_SELECTION_WITH_ATT_S-NOTIFICATION_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_QOD_NOTIF_SELECTION_WITH_ATT_S-NOTIFICATION_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_QOD_NOTIF_SELECTION_WITH_ATT_S-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_QOD_NOTIF_SELECTION_WITH_ATT_S-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field NOTIFICATION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_QOD_NOTIF_SELECTION_WITH_ATT_S-NOTIFICATION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_QOD_NOTIF_SELECTION_WITH_ATT_S-NOTIFICATION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit SXIDN, internal->external for field PARTNER_EMAIL CALL FUNCTION 'CONVERSION_EXIT_SXIDN_OUTPUT' EXPORTING input = WA_QOD_NOTIF_SELECTION_WITH_ATT_S-PARTNER_EMAIL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_QOD_NOTIF_SELECTION_WITH_ATT_S-PARTNER_EMAIL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNER_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_QOD_NOTIF_SELECTION_WITH_ATT_S-PARTNER_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_QOD_NOTIF_SELECTION_WITH_ATT_S-PARTNER_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_QOD_NOTIF_SELECTION_WITH_ATT_S_STR,
NOTIFICATION_ID TYPE STRING,
SHORT_TEXT TYPE STRING,
REFERENCE_NUMBER TYPE STRING,
LONG_TEXT TYPE STRING,
PRIORITY_TEXT TYPE STRING,
CREATED_ON TYPE STRING,
CREATED_BY TYPE STRING,
START_TIME TYPE STRING,
MATNR TYPE STRING,
MATERIAL_TEXT TYPE STRING,
NOTIF_CODE_TEXT TYPE STRING,
NOTIF_CODE_GROUP_TEXT TYPE STRING,
DEFECT_CODE_TEXT TYPE STRING,
DEFECT_CODE_GROUP_TEXT TYPE STRING,
NOTIFICATION TYPE STRING,
ATTACHMENT TYPE STRING,
ATT_COUNT TYPE STRING,
STATUS TYPE STRING,
STATUS_TEXT TYPE STRING,
PARTNER_NAME TYPE STRING,
PARTNER_MPHONE TYPE STRING,
PARTNER_WPHONE TYPE STRING,
PARTNER_EMAIL TYPE STRING,
PARTNER_COMPANY TYPE STRING,
DUMMY_PARTNER_INCL TYPE STRING,
PARTNER_ID TYPE STRING,
DUMMY_NOTIF_SEL_INCL TYPE STRING,
QMATTACHMENTSELECTIONSET TYPE STRING,END OF T_EKKO_STR. DATA: WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-NOTIFICATION_ID sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-SHORT_TEXT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-REFERENCE_NUMBER sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-LONG_TEXT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-PRIORITY_TEXT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-CREATED_ON sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-CREATED_BY sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-START_TIME sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-MATNR sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-MATERIAL_TEXT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-NOTIF_CODE_TEXT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-NOTIF_CODE_GROUP_TEXT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-DEFECT_CODE_TEXT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-DEFECT_CODE_GROUP_TEXT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-NOTIFICATION sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-ATTACHMENT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-ATT_COUNT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-STATUS sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-STATUS_TEXT sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-PARTNER_NAME sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-PARTNER_MPHONE sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-PARTNER_WPHONE sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-PARTNER_EMAIL sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-PARTNER_COMPANY sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-DUMMY_PARTNER_INCL sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-PARTNER_ID sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-DUMMY_NOTIF_SEL_INCL sy-vline
WA_QOD_NOTIF_SELECTION_WITH_ATT_S_STR-QMATTACHMENTSELECTIONSET sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.