ABAP Select data from SAP table QCERT_TS_QCVK_MIG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP QCERT_TS_QCVK_MIG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to QCERT_TS_QCVK_MIG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the QCERT_TS_QCVK_MIG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_QCERT_TS_QCVK_MIG TYPE STANDARD TABLE OF QCERT_TS_QCVK_MIG,
      WA_QCERT_TS_QCVK_MIG TYPE QCERT_TS_QCVK_MIG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <QCERT_TS_QCVK_MIG> TYPE QCERT_TS_QCVK_MIG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_QCERT_TS_QCVK_MIG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM QCERT_TS_QCVK_MIG
  INTO TABLE IT_QCERT_TS_QCVK_MIG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM QCERT_TS_QCVK_MIG
*  INTO TABLE @DATA(IT_QCERT_TS_QCVK_MIG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_QCERT_TS_QCVK_MIG INDEX 1 INTO DATA(WA_QCERT_TS_QCVK_MIG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_QCERT_TS_QCVK_MIG ASSIGNING <QCERT_TS_QCVK_MIG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<QCERT_TS_QCVK_MIG>-SENDER_TECHNICAL_ID = 1.
<QCERT_TS_QCVK_MIG>-MANDANT = 1.
<QCERT_TS_QCVK_MIG>-CTYP = 1.
<QCERT_TS_QCVK_MIG>-VORLNR = 1.
<QCERT_TS_QCVK_MIG>-VERSION = 1.
ENDLOOP.

LOOP AT IT_QCERT_TS_QCVK_MIG INTO WA_QCERT_TS_QCVK_MIG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_QCERT_TS_QCVK_MIG-SORTFELD, sy-vline,
WA_QCERT_TS_QCVK_MIG-GUELTIGAB, sy-vline,
WA_QCERT_TS_QCVK_MIG-OBJNR, sy-vline,
WA_QCERT_TS_QCVK_MIG-OBTYP, sy-vline,
WA_QCERT_TS_QCVK_MIG-STSMA, sy-vline,
WA_QCERT_TS_QCVK_MIG-ERSTELLER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_QCERT_TS_QCVK_MIG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_QCERT_TS_QCVK_MIG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_QCERT_TS_QCVK_MIG INTO WA_QCERT_TS_QCVK_MIG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field VERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_QCERT_TS_QCVK_MIG-VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_QCERT_TS_QCVK_MIG-VERSION.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_QCERT_TS_QCVK_MIG_STR,
SENDER_TECHNICAL_ID TYPE STRING,
MANDANT TYPE STRING,
CTYP TYPE STRING,
VORLNR TYPE STRING,
VERSION TYPE STRING,
SORTFELD TYPE STRING,
GUELTIGAB TYPE STRING,
OBJNR TYPE STRING,
OBTYP TYPE STRING,
STSMA TYPE STRING,
ERSTELLER TYPE STRING,
ERSTELDAT TYPE STRING,
AENDERER TYPE STRING,
AENDERDAT TYPE STRING,
TDFORM TYPE STRING,
KZGUTLOSE TYPE STRING,
MINQKZ TYPE STRING,
KZLASTLOT TYPE STRING,
KZLIEFSCH TYPE STRING,
HERKUNFT TYPE STRING,
ART TYPE STRING,
KONSISTENT TYPE STRING,
KURZTEXT TYPE STRING,
LTEXTKZ TYPE STRING,
WITHTRANSF TYPE STRING,
QDI_NOPDF TYPE STRING,
ALSTF TYPE STRING,
ADBFORM TYPE STRING,
QKZ_USEADB TYPE STRING,
CHAR_FIELD_CONF TYPE STRING,
CHANGEDDATETIME TYPE STRING,
Q_CERT_PROFILE_STATUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_QCERT_TS_QCVK_MIG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_QCERT_TS_QCVK_MIG_STR-SENDER_TECHNICAL_ID sy-vline
WA_QCERT_TS_QCVK_MIG_STR-MANDANT sy-vline
WA_QCERT_TS_QCVK_MIG_STR-CTYP sy-vline
WA_QCERT_TS_QCVK_MIG_STR-VORLNR sy-vline
WA_QCERT_TS_QCVK_MIG_STR-VERSION sy-vline
WA_QCERT_TS_QCVK_MIG_STR-SORTFELD sy-vline
WA_QCERT_TS_QCVK_MIG_STR-GUELTIGAB sy-vline
WA_QCERT_TS_QCVK_MIG_STR-OBJNR sy-vline
WA_QCERT_TS_QCVK_MIG_STR-OBTYP sy-vline
WA_QCERT_TS_QCVK_MIG_STR-STSMA sy-vline
WA_QCERT_TS_QCVK_MIG_STR-ERSTELLER sy-vline
WA_QCERT_TS_QCVK_MIG_STR-ERSTELDAT sy-vline
WA_QCERT_TS_QCVK_MIG_STR-AENDERER sy-vline
WA_QCERT_TS_QCVK_MIG_STR-AENDERDAT sy-vline
WA_QCERT_TS_QCVK_MIG_STR-TDFORM sy-vline
WA_QCERT_TS_QCVK_MIG_STR-KZGUTLOSE sy-vline
WA_QCERT_TS_QCVK_MIG_STR-MINQKZ sy-vline
WA_QCERT_TS_QCVK_MIG_STR-KZLASTLOT sy-vline
WA_QCERT_TS_QCVK_MIG_STR-KZLIEFSCH sy-vline
WA_QCERT_TS_QCVK_MIG_STR-HERKUNFT sy-vline
WA_QCERT_TS_QCVK_MIG_STR-ART sy-vline
WA_QCERT_TS_QCVK_MIG_STR-KONSISTENT sy-vline
WA_QCERT_TS_QCVK_MIG_STR-KURZTEXT sy-vline
WA_QCERT_TS_QCVK_MIG_STR-LTEXTKZ sy-vline
WA_QCERT_TS_QCVK_MIG_STR-WITHTRANSF sy-vline
WA_QCERT_TS_QCVK_MIG_STR-QDI_NOPDF sy-vline
WA_QCERT_TS_QCVK_MIG_STR-ALSTF sy-vline
WA_QCERT_TS_QCVK_MIG_STR-ADBFORM sy-vline
WA_QCERT_TS_QCVK_MIG_STR-QKZ_USEADB sy-vline
WA_QCERT_TS_QCVK_MIG_STR-CHAR_FIELD_CONF sy-vline
WA_QCERT_TS_QCVK_MIG_STR-CHANGEDDATETIME sy-vline
WA_QCERT_TS_QCVK_MIG_STR-Q_CERT_PROFILE_STATUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.