ABAP Select data from SAP table Q3417 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP Q3417 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to Q3417. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the Q3417 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_Q3417 TYPE STANDARD TABLE OF Q3417,
      WA_Q3417 TYPE Q3417,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <Q3417> TYPE Q3417.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_Q3417.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM Q3417
  INTO TABLE IT_Q3417.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM Q3417
*  INTO TABLE @DATA(IT_Q34172).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_Q3417 INDEX 1 INTO DATA(WA_Q34172).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_Q3417 ASSIGNING <Q3417>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<Q3417>-TNORM = 1.
<Q3417>-T_TRTYP = 1.
<Q3417>-T_SUBTY = 1.
<Q3417>-T_SBTTX = 1.
<Q3417>-T_OBJPS = 1.
ENDLOOP.

LOOP AT IT_Q3417 INTO WA_Q3417.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_Q3417-T_TRNAM, sy-vline,
WA_Q3417-T_TRBEG, sy-vline,
WA_Q3417-T_TREND, sy-vline,
WA_Q3417-T_TRCOM, sy-vline,
WA_Q3417-T_TRXPR, sy-vline,
WA_Q3417-T_TRFTX, sy-vline.
ENDLOOP. *Add any further fields from structure WA_Q3417 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_Q3417 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_Q3417 INTO WA_Q3417. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_Q3417_STR,
TNORM TYPE STRING,
T_TRTYP TYPE STRING,
T_SUBTY TYPE STRING,
T_SBTTX TYPE STRING,
T_OBJPS TYPE STRING,
T_TRNAM TYPE STRING,
T_TRBEG TYPE STRING,
T_TREND TYPE STRING,
T_TRCOM TYPE STRING,
T_TRXPR TYPE STRING,
T_TRFTX TYPE STRING,
SELEC TYPE STRING,
B_TRTYP TYPE STRING,
B_SUBTY TYPE STRING,
B_SBTTX TYPE STRING,
B_OBJPS TYPE STRING,
B_TRNAM TYPE STRING,
B_TRBEG TYPE STRING,
B_TREND TYPE STRING,
B_TRCOM TYPE STRING,
B_TRXPR TYPE STRING,
B_TRFTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_Q3417_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_Q3417_STR-TNORM sy-vline
WA_Q3417_STR-T_TRTYP sy-vline
WA_Q3417_STR-T_SUBTY sy-vline
WA_Q3417_STR-T_SBTTX sy-vline
WA_Q3417_STR-T_OBJPS sy-vline
WA_Q3417_STR-T_TRNAM sy-vline
WA_Q3417_STR-T_TRBEG sy-vline
WA_Q3417_STR-T_TREND sy-vline
WA_Q3417_STR-T_TRCOM sy-vline
WA_Q3417_STR-T_TRXPR sy-vline
WA_Q3417_STR-T_TRFTX sy-vline
WA_Q3417_STR-SELEC sy-vline
WA_Q3417_STR-B_TRTYP sy-vline
WA_Q3417_STR-B_SUBTY sy-vline
WA_Q3417_STR-B_SBTTX sy-vline
WA_Q3417_STR-B_OBJPS sy-vline
WA_Q3417_STR-B_TRNAM sy-vline
WA_Q3417_STR-B_TRBEG sy-vline
WA_Q3417_STR-B_TREND sy-vline
WA_Q3417_STR-B_TRCOM sy-vline
WA_Q3417_STR-B_TRXPR sy-vline
WA_Q3417_STR-B_TRFTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.