ABAP Select data from SAP table Q0657 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP Q0657 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to Q0657. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the Q0657 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_Q0657 TYPE STANDARD TABLE OF Q0657,
      WA_Q0657 TYPE Q0657,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <Q0657> TYPE Q0657.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_Q0657.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM Q0657
  INTO TABLE IT_Q0657.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM Q0657
*  INTO TABLE @DATA(IT_Q06572).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_Q0657 INDEX 1 INTO DATA(WA_Q06572).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_Q0657 ASSIGNING <Q0657>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<Q0657>-CNTDT = 1.
<Q0657>-PYMDT = 1.
<Q0657>-BETRG = 1.
<Q0657>-EITXT = 1.
<Q0657>-INDBW = 1.
ENDLOOP.

LOOP AT IT_Q0657 INTO WA_Q0657.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_Q0657-MOLGA, sy-vline,
WA_Q0657-LGMUS, sy-vline,
WA_Q0657-BANKS, sy-vline,
WA_Q0657-BANKL, sy-vline,
WA_Q0657-BANKN, sy-vline,
WA_Q0657-ZLSCH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_Q0657 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_Q0657 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_Q0657 INTO WA_Q0657. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_Q0657_STR,
CNTDT TYPE STRING,
PYMDT TYPE STRING,
BETRG TYPE STRING,
EITXT TYPE STRING,
INDBW TYPE STRING,
MOLGA TYPE STRING,
LGMUS TYPE STRING,
BANKS TYPE STRING,
BANKL TYPE STRING,
BANKN TYPE STRING,
ZLSCH TYPE STRING,
CALDY TYPE STRING,
CNAMT TYPE STRING,
PYSUM TYPE STRING,
PAYTY TYPE STRING,
PAYID TYPE STRING,
CNTN4 TYPE STRING,END OF T_EKKO_STR. DATA: WA_Q0657_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_Q0657_STR-CNTDT sy-vline
WA_Q0657_STR-PYMDT sy-vline
WA_Q0657_STR-BETRG sy-vline
WA_Q0657_STR-EITXT sy-vline
WA_Q0657_STR-INDBW sy-vline
WA_Q0657_STR-MOLGA sy-vline
WA_Q0657_STR-LGMUS sy-vline
WA_Q0657_STR-BANKS sy-vline
WA_Q0657_STR-BANKL sy-vline
WA_Q0657_STR-BANKN sy-vline
WA_Q0657_STR-ZLSCH sy-vline
WA_Q0657_STR-CALDY sy-vline
WA_Q0657_STR-CNAMT sy-vline
WA_Q0657_STR-PYSUM sy-vline
WA_Q0657_STR-PAYTY sy-vline
WA_Q0657_STR-PAYID sy-vline
WA_Q0657_STR-CNTN4 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.