ABAP Select data from SAP table Q0632 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP Q0632 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to Q0632. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the Q0632 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_Q0632 TYPE STANDARD TABLE OF Q0632,
      WA_Q0632 TYPE Q0632,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <Q0632> TYPE Q0632.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_Q0632.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM Q0632
  INTO TABLE IT_Q0632.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM Q0632
*  INTO TABLE @DATA(IT_Q06322).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_Q0632 INDEX 1 INTO DATA(WA_Q06322).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_Q0632 ASSIGNING <Q0632>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<Q0632>-ATZGD = 1.
<Q0632>-ATZBH = 1.
<Q0632>-RWGBA = 1.
<Q0632>-RWSUM = 1.
<Q0632>-RWTOT = 1.
ENDLOOP.

LOOP AT IT_Q0632 INTO WA_Q0632.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_Q0632-SWGBA, sy-vline,
WA_Q0632-SWSUM, sy-vline,
WA_Q0632-SWTOT, sy-vline,
WA_Q0632-ATZWH, sy-vline,
WA_Q0632-ANREX, sy-vline,
WA_Q0632-ARTIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_Q0632 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_Q0632 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_Q0632 INTO WA_Q0632. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_Q0632_STR,
ATZGD TYPE STRING,
ATZBH TYPE STRING,
RWGBA TYPE STRING,
RWSUM TYPE STRING,
RWTOT TYPE STRING,
SWGBA TYPE STRING,
SWSUM TYPE STRING,
SWTOT TYPE STRING,
ATZWH TYPE STRING,
ANREX TYPE STRING,
ARTIT TYPE STRING,
ARVSW TYPE STRING,
ARNAM TYPE STRING,
AUSVG TYPE STRING,
AVOLL TYPE STRING,
ALEHR TYPE STRING,
ASTAX TYPE STRING,
R3TAB TYPE STRING,
EXTAB TYPE STRING,
R3DAT TYPE STRING,
EXDAT TYPE STRING,
R3TXT TYPE STRING,
EXTXT TYPE STRING,
AMDTX TYPE STRING,
NOARE TYPE STRING,END OF T_EKKO_STR. DATA: WA_Q0632_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_Q0632_STR-ATZGD sy-vline
WA_Q0632_STR-ATZBH sy-vline
WA_Q0632_STR-RWGBA sy-vline
WA_Q0632_STR-RWSUM sy-vline
WA_Q0632_STR-RWTOT sy-vline
WA_Q0632_STR-SWGBA sy-vline
WA_Q0632_STR-SWSUM sy-vline
WA_Q0632_STR-SWTOT sy-vline
WA_Q0632_STR-ATZWH sy-vline
WA_Q0632_STR-ANREX sy-vline
WA_Q0632_STR-ARTIT sy-vline
WA_Q0632_STR-ARVSW sy-vline
WA_Q0632_STR-ARNAM sy-vline
WA_Q0632_STR-AUSVG sy-vline
WA_Q0632_STR-AVOLL sy-vline
WA_Q0632_STR-ALEHR sy-vline
WA_Q0632_STR-ASTAX sy-vline
WA_Q0632_STR-R3TAB sy-vline
WA_Q0632_STR-EXTAB sy-vline
WA_Q0632_STR-R3DAT sy-vline
WA_Q0632_STR-EXDAT sy-vline
WA_Q0632_STR-R3TXT sy-vline
WA_Q0632_STR-EXTXT sy-vline
WA_Q0632_STR-AMDTX sy-vline
WA_Q0632_STR-NOARE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.