ABAP Select data from SAP table Q0196 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP Q0196 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to Q0196. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the Q0196 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_Q0196 TYPE STANDARD TABLE OF Q0196,
      WA_Q0196 TYPE Q0196,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <Q0196> TYPE Q0196.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_Q0196.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM Q0196
  INTO TABLE IT_Q0196.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM Q0196
*  INTO TABLE @DATA(IT_Q01962).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_Q0196 INDEX 1 INTO DATA(WA_Q01962).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_Q0196 ASSIGNING <Q0196>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<Q0196>-CPCEE = 1.
<Q0196>-CPCER = 1.
<Q0196>-ASDTE = 1.
<Q0196>-EESRT = 1.
<Q0196>-EECRT = 1.
ENDLOOP.

LOOP AT IT_Q0196 INTO WA_Q0196.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_Q0196-EEPRT, sy-vline,
WA_Q0196-ERSRT, sy-vline,
WA_Q0196-ERCRT, sy-vline,
WA_Q0196-ERPRT, sy-vline,
WA_Q0196-OPEET, sy-vline,
WA_Q0196-OPRET, sy-vline.
ENDLOOP. *Add any further fields from structure WA_Q0196 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_Q0196 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_Q0196 INTO WA_Q0196. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_Q0196_STR,
CPCEE TYPE STRING,
CPCER TYPE STRING,
ASDTE TYPE STRING,
EESRT TYPE STRING,
EECRT TYPE STRING,
EEPRT TYPE STRING,
ERSRT TYPE STRING,
ERCRT TYPE STRING,
ERPRT TYPE STRING,
OPEET TYPE STRING,
OPRET TYPE STRING,
RETPA TYPE STRING,
RETAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_Q0196_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_Q0196_STR-CPCEE sy-vline
WA_Q0196_STR-CPCER sy-vline
WA_Q0196_STR-ASDTE sy-vline
WA_Q0196_STR-EESRT sy-vline
WA_Q0196_STR-EECRT sy-vline
WA_Q0196_STR-EEPRT sy-vline
WA_Q0196_STR-ERSRT sy-vline
WA_Q0196_STR-ERCRT sy-vline
WA_Q0196_STR-ERPRT sy-vline
WA_Q0196_STR-OPEET sy-vline
WA_Q0196_STR-OPRET sy-vline
WA_Q0196_STR-RETPA sy-vline
WA_Q0196_STR-RETAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.