ABAP Select data from SAP table Q0114 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP Q0114 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to Q0114. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the Q0114 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_Q0114 TYPE STANDARD TABLE OF Q0114,
      WA_Q0114 TYPE Q0114,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <Q0114> TYPE Q0114.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_Q0114.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM Q0114
  INTO TABLE IT_Q0114.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM Q0114
*  INTO TABLE @DATA(IT_Q01142).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_Q0114 INDEX 1 INTO DATA(WA_Q01142).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_Q0114 ASSIGNING <Q0114>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<Q0114>-UNBER = 1.
<Q0114>-SEQNR = 1.
<Q0114>-STEXT = 1.
<Q0114>-VWANK = 1.
<Q0114>-VWLGA = 1.
ENDLOOP.

LOOP AT IT_Q0114 INTO WA_Q0114.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_Q0114-VWNUM, sy-vline,
WA_Q0114-VWAGA, sy-vline,
WA_Q0114-VWANL, sy-vline,
WA_Q0114-VWBTR, sy-vline,
WA_Q0114-VWEMF, sy-vline,
WA_Q0114-VWEMT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_Q0114 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_Q0114 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_Q0114 INTO WA_Q0114. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_Q0114_STR,
UNBER TYPE STRING,
SEQNR TYPE STRING,
STEXT TYPE STRING,
VWANK TYPE STRING,
VWLGA TYPE STRING,
VWNUM TYPE STRING,
VWAGA TYPE STRING,
VWANL TYPE STRING,
VWBTR TYPE STRING,
VWEMF TYPE STRING,
VWEMT TYPE STRING,
VWMSA TYPE STRING,
GNAV1 TYPE STRING,
GNAV2 TYPE STRING,
GNAV3 TYPE STRING,
VIGNA TYPE STRING,
VIART TYPE STRING,
VINUM TYPE STRING,
LSTJA TYPE STRING,
PAGEA TYPE STRING,
PAGEC TYPE STRING,
WAE01 TYPE STRING,
WAE02 TYPE STRING,
WAE03 TYPE STRING,
WAE04 TYPE STRING,
WAE05 TYPE STRING,
EINH1 TYPE STRING,
EINH2 TYPE STRING,
EINH3 TYPE STRING,
EINH4 TYPE STRING,
EINH5 TYPE STRING,
EINH6 TYPE STRING,
FTXT1 TYPE STRING,
FTXT2 TYPE STRING,
FTXT3 TYPE STRING,
FTXT4 TYPE STRING,
FTXT5 TYPE STRING,
FTXT6 TYPE STRING,
ZVER0 TYPE STRING,
ZVER1 TYPE STRING,
ZVER2 TYPE STRING,
ZMEH1 TYPE STRING,
ZMEH2 TYPE STRING,
ZMEI1 TYPE STRING,
ZMEI2 TYPE STRING,
AVANK TYPE STRING,
ANLAR TYPE STRING,
OBJPS TYPE STRING,
AINTX TYPE STRING,
ANNUM TYPE STRING,
VTMOD TYPE STRING,
SUBTY TYPE STRING,END OF T_EKKO_STR. DATA: WA_Q0114_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_Q0114_STR-UNBER sy-vline
WA_Q0114_STR-SEQNR sy-vline
WA_Q0114_STR-STEXT sy-vline
WA_Q0114_STR-VWANK sy-vline
WA_Q0114_STR-VWLGA sy-vline
WA_Q0114_STR-VWNUM sy-vline
WA_Q0114_STR-VWAGA sy-vline
WA_Q0114_STR-VWANL sy-vline
WA_Q0114_STR-VWBTR sy-vline
WA_Q0114_STR-VWEMF sy-vline
WA_Q0114_STR-VWEMT sy-vline
WA_Q0114_STR-VWMSA sy-vline
WA_Q0114_STR-GNAV1 sy-vline
WA_Q0114_STR-GNAV2 sy-vline
WA_Q0114_STR-GNAV3 sy-vline
WA_Q0114_STR-VIGNA sy-vline
WA_Q0114_STR-VIART sy-vline
WA_Q0114_STR-VINUM sy-vline
WA_Q0114_STR-LSTJA sy-vline
WA_Q0114_STR-PAGEA sy-vline
WA_Q0114_STR-PAGEC sy-vline
WA_Q0114_STR-WAE01 sy-vline
WA_Q0114_STR-WAE02 sy-vline
WA_Q0114_STR-WAE03 sy-vline
WA_Q0114_STR-WAE04 sy-vline
WA_Q0114_STR-WAE05 sy-vline
WA_Q0114_STR-EINH1 sy-vline
WA_Q0114_STR-EINH2 sy-vline
WA_Q0114_STR-EINH3 sy-vline
WA_Q0114_STR-EINH4 sy-vline
WA_Q0114_STR-EINH5 sy-vline
WA_Q0114_STR-EINH6 sy-vline
WA_Q0114_STR-FTXT1 sy-vline
WA_Q0114_STR-FTXT2 sy-vline
WA_Q0114_STR-FTXT3 sy-vline
WA_Q0114_STR-FTXT4 sy-vline
WA_Q0114_STR-FTXT5 sy-vline
WA_Q0114_STR-FTXT6 sy-vline
WA_Q0114_STR-ZVER0 sy-vline
WA_Q0114_STR-ZVER1 sy-vline
WA_Q0114_STR-ZVER2 sy-vline
WA_Q0114_STR-ZMEH1 sy-vline
WA_Q0114_STR-ZMEH2 sy-vline
WA_Q0114_STR-ZMEI1 sy-vline
WA_Q0114_STR-ZMEI2 sy-vline
WA_Q0114_STR-AVANK sy-vline
WA_Q0114_STR-ANLAR sy-vline
WA_Q0114_STR-OBJPS sy-vline
WA_Q0114_STR-AINTX sy-vline
WA_Q0114_STR-ANNUM sy-vline
WA_Q0114_STR-VTMOD sy-vline
WA_Q0114_STR-SUBTY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.