ABAP Select data from SAP table Q0111 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP Q0111 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to Q0111. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the Q0111 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_Q0111 TYPE STANDARD TABLE OF Q0111,
      WA_Q0111 TYPE Q0111,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <Q0111> TYPE Q0111.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_Q0111.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM Q0111
  INTO TABLE IT_Q0111.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM Q0111
*  INTO TABLE @DATA(IT_Q01112).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_Q0111 INDEX 1 INTO DATA(WA_Q01112).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_Q0111 ASSIGNING <Q0111>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<Q0111>-PFART = 1.
<Q0111>-PFNUM = 1.
<Q0111>-ENDDA = 1.
<Q0111>-BEGDA = 1.
<Q0111>-GLART = 1.
ENDLOOP.

LOOP AT IT_Q0111 INTO WA_Q0111.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_Q0111-GLPRO, sy-vline,
WA_Q0111-GLBAR, sy-vline,
WA_Q0111-GLBPR, sy-vline,
WA_Q0111-GLFIR, sy-vline,
WA_Q0111-GLABT, sy-vline,
WA_Q0111-GLANR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_Q0111 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_Q0111 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_Q0111 INTO WA_Q0111. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_Q0111_STR,
PFART TYPE STRING,
PFNUM TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
GLART TYPE STRING,
GLPRO TYPE STRING,
GLBAR TYPE STRING,
GLBPR TYPE STRING,
GLFIR TYPE STRING,
GLABT TYPE STRING,
GLANR TYPE STRING,
GLTIT TYPE STRING,
GLVOR TYPE STRING,
GLNAM TYPE STRING,
GLSTR TYPE STRING,
GLLND TYPE STRING,
GLPLZ TYPE STRING,
GLORT TYPE STRING,
GLTEL TYPE STRING,
KENNZ TYPE STRING,
INBEG TYPE STRING,
INEND TYPE STRING,
GERBE TYPE STRING,
KOFIR TYPE STRING,
KOABT TYPE STRING,
KOTIT TYPE STRING,
KOANR TYPE STRING,
KOVOR TYPE STRING,
KONAM TYPE STRING,
KOSTR TYPE STRING,
KOLND TYPE STRING,
KOPLZ TYPE STRING,
KOORT TYPE STRING,
KOTEL TYPE STRING,
KORRE TYPE STRING,
INTVA TYPE STRING,
INTVC TYPE STRING,
FRAME1 TYPE STRING,
STTXT TYPE STRING,
GLAUB TYPE STRING,END OF T_EKKO_STR. DATA: WA_Q0111_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_Q0111_STR-PFART sy-vline
WA_Q0111_STR-PFNUM sy-vline
WA_Q0111_STR-ENDDA sy-vline
WA_Q0111_STR-BEGDA sy-vline
WA_Q0111_STR-GLART sy-vline
WA_Q0111_STR-GLPRO sy-vline
WA_Q0111_STR-GLBAR sy-vline
WA_Q0111_STR-GLBPR sy-vline
WA_Q0111_STR-GLFIR sy-vline
WA_Q0111_STR-GLABT sy-vline
WA_Q0111_STR-GLANR sy-vline
WA_Q0111_STR-GLTIT sy-vline
WA_Q0111_STR-GLVOR sy-vline
WA_Q0111_STR-GLNAM sy-vline
WA_Q0111_STR-GLSTR sy-vline
WA_Q0111_STR-GLLND sy-vline
WA_Q0111_STR-GLPLZ sy-vline
WA_Q0111_STR-GLORT sy-vline
WA_Q0111_STR-GLTEL sy-vline
WA_Q0111_STR-KENNZ sy-vline
WA_Q0111_STR-INBEG sy-vline
WA_Q0111_STR-INEND sy-vline
WA_Q0111_STR-GERBE sy-vline
WA_Q0111_STR-KOFIR sy-vline
WA_Q0111_STR-KOABT sy-vline
WA_Q0111_STR-KOTIT sy-vline
WA_Q0111_STR-KOANR sy-vline
WA_Q0111_STR-KOVOR sy-vline
WA_Q0111_STR-KONAM sy-vline
WA_Q0111_STR-KOSTR sy-vline
WA_Q0111_STR-KOLND sy-vline
WA_Q0111_STR-KOPLZ sy-vline
WA_Q0111_STR-KOORT sy-vline
WA_Q0111_STR-KOTEL sy-vline
WA_Q0111_STR-KORRE sy-vline
WA_Q0111_STR-INTVA sy-vline
WA_Q0111_STR-INTVC sy-vline
WA_Q0111_STR-FRAME1 sy-vline
WA_Q0111_STR-STTXT sy-vline
WA_Q0111_STR-GLAUB sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.