ABAP Select data from SAP table Q0021H into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP Q0021H table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to Q0021H. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the Q0021H table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_Q0021H TYPE STANDARD TABLE OF Q0021H,
      WA_Q0021H TYPE Q0021H,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <Q0021H> TYPE Q0021H.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_Q0021H.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM Q0021H
  INTO TABLE IT_Q0021H.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM Q0021H
*  INTO TABLE @DATA(IT_Q0021H2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_Q0021H INDEX 1 INTO DATA(WA_Q0021H2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_Q0021H ASSIGNING <Q0021H>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<Q0021H>-PERNR = 1.
<Q0021H>-PITYP = 1.
<Q0021H>-PERID = 1.
<Q0021H>-SVNUM = 1.
<Q0021H>-SVKNR = 1.
ENDLOOP.

LOOP AT IT_Q0021H INTO WA_Q0021H.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_Q0021H-STAT1, sy-vline,
WA_Q0021H-STAT2, sy-vline,
WA_Q0021H-STAT3, sy-vline,
WA_Q0021H-STAT4, sy-vline,
WA_Q0021H-STAT5, sy-vline,
WA_Q0021H-STAT6, sy-vline.
ENDLOOP. *Add any further fields from structure WA_Q0021H you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_Q0021H TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_Q0021H INTO WA_Q0021H. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_Q0021H_STR,
PERNR TYPE STRING,
PITYP TYPE STRING,
PERID TYPE STRING,
SVNUM TYPE STRING,
SVKNR TYPE STRING,
STAT1 TYPE STRING,
STAT2 TYPE STRING,
STAT3 TYPE STRING,
STAT4 TYPE STRING,
STAT5 TYPE STRING,
STAT6 TYPE STRING,
PYTEX TYPE STRING,
STAT7 TYPE STRING,
TBTXT TYPE STRING,
ADOKD TYPE STRING,
ADOTX TYPE STRING,
ELEVF TYPE STRING,
EKHSZ TYPE STRING,
CSKJC TYPE STRING,
CJCTX TYPE STRING,END OF T_EKKO_STR. DATA: WA_Q0021H_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_Q0021H_STR-PERNR sy-vline
WA_Q0021H_STR-PITYP sy-vline
WA_Q0021H_STR-PERID sy-vline
WA_Q0021H_STR-SVNUM sy-vline
WA_Q0021H_STR-SVKNR sy-vline
WA_Q0021H_STR-STAT1 sy-vline
WA_Q0021H_STR-STAT2 sy-vline
WA_Q0021H_STR-STAT3 sy-vline
WA_Q0021H_STR-STAT4 sy-vline
WA_Q0021H_STR-STAT5 sy-vline
WA_Q0021H_STR-STAT6 sy-vline
WA_Q0021H_STR-PYTEX sy-vline
WA_Q0021H_STR-STAT7 sy-vline
WA_Q0021H_STR-TBTXT sy-vline
WA_Q0021H_STR-ADOKD sy-vline
WA_Q0021H_STR-ADOTX sy-vline
WA_Q0021H_STR-ELEVF sy-vline
WA_Q0021H_STR-EKHSZ sy-vline
WA_Q0021H_STR-CSKJC sy-vline
WA_Q0021H_STR-CJCTX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.