ABAP Select data from SAP table PYC_PEM_S_WORKLIST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PYC_PEM_S_WORKLIST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PYC_PEM_S_WORKLIST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PYC_PEM_S_WORKLIST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PYC_PEM_S_WORKLIST TYPE STANDARD TABLE OF PYC_PEM_S_WORKLIST,
      WA_PYC_PEM_S_WORKLIST TYPE PYC_PEM_S_WORKLIST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PYC_PEM_S_WORKLIST> TYPE PYC_PEM_S_WORKLIST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PYC_PEM_S_WORKLIST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PYC_PEM_S_WORKLIST
  INTO TABLE IT_PYC_PEM_S_WORKLIST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PYC_PEM_S_WORKLIST
*  INTO TABLE @DATA(IT_PYC_PEM_S_WORKLIST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PYC_PEM_S_WORKLIST INDEX 1 INTO DATA(WA_PYC_PEM_S_WORKLIST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PYC_PEM_S_WORKLIST ASSIGNING <PYC_PEM_S_WORKLIST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PYC_PEM_S_WORKLIST>-ID = 1.
<PYC_PEM_S_WORKLIST>-UNAME = 1.
<PYC_PEM_S_WORKLIST>-INST_SEL_PAR_TYPE = 1.
<PYC_PEM_S_WORKLIST>-TIME_SEL_PAR_TYPE = 1.
<PYC_PEM_S_WORKLIST>-PROC_ID = 1.
ENDLOOP.

LOOP AT IT_PYC_PEM_S_WORKLIST INTO WA_PYC_PEM_S_WORKLIST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PYC_PEM_S_WORKLIST-PROC_NAME, sy-vline,
WA_PYC_PEM_S_WORKLIST-PYPI_ID, sy-vline,
WA_PYC_PEM_S_WORKLIST-PROC_INST_NAME, sy-vline,
WA_PYC_PEM_S_WORKLIST-STEP_ID, sy-vline,
WA_PYC_PEM_S_WORKLIST-TIME_SEL_PAR_VAL, sy-vline,
WA_PYC_PEM_S_WORKLIST-ERROR_COUNT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PYC_PEM_S_WORKLIST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PYC_PEM_S_WORKLIST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PYC_PEM_S_WORKLIST INTO WA_PYC_PEM_S_WORKLIST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CKINP, internal->external for field PROC_ID CALL FUNCTION 'CONVERSION_EXIT_CKINP_OUTPUT' EXPORTING input = WA_PYC_PEM_S_WORKLIST-PROC_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PYC_PEM_S_WORKLIST-PROC_ID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CKINP, internal->external for field STEP_ID CALL FUNCTION 'CONVERSION_EXIT_CKINP_OUTPUT' EXPORTING input = WA_PYC_PEM_S_WORKLIST-STEP_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PYC_PEM_S_WORKLIST-STEP_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PYC_PEM_S_WORKLIST_STR,
ID TYPE STRING,
UNAME TYPE STRING,
INST_SEL_PAR_TYPE TYPE STRING,
TIME_SEL_PAR_TYPE TYPE STRING,
PROC_ID TYPE STRING,
PROC_NAME TYPE STRING,
PYPI_ID TYPE STRING,
PROC_INST_NAME TYPE STRING,
STEP_ID TYPE STRING,
TIME_SEL_PAR_VAL TYPE STRING,
ERROR_COUNT TYPE STRING,
ERROR_STATUS TYPE STRING,
DUE_DATE_TIME TYPE STRING,
DUE_DATE_TIME_HAS_TIME TYPE STRING,END OF T_EKKO_STR. DATA: WA_PYC_PEM_S_WORKLIST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PYC_PEM_S_WORKLIST_STR-ID sy-vline
WA_PYC_PEM_S_WORKLIST_STR-UNAME sy-vline
WA_PYC_PEM_S_WORKLIST_STR-INST_SEL_PAR_TYPE sy-vline
WA_PYC_PEM_S_WORKLIST_STR-TIME_SEL_PAR_TYPE sy-vline
WA_PYC_PEM_S_WORKLIST_STR-PROC_ID sy-vline
WA_PYC_PEM_S_WORKLIST_STR-PROC_NAME sy-vline
WA_PYC_PEM_S_WORKLIST_STR-PYPI_ID sy-vline
WA_PYC_PEM_S_WORKLIST_STR-PROC_INST_NAME sy-vline
WA_PYC_PEM_S_WORKLIST_STR-STEP_ID sy-vline
WA_PYC_PEM_S_WORKLIST_STR-TIME_SEL_PAR_VAL sy-vline
WA_PYC_PEM_S_WORKLIST_STR-ERROR_COUNT sy-vline
WA_PYC_PEM_S_WORKLIST_STR-ERROR_STATUS sy-vline
WA_PYC_PEM_S_WORKLIST_STR-DUE_DATE_TIME sy-vline
WA_PYC_PEM_S_WORKLIST_STR-DUE_DATE_TIME_HAS_TIME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.