ABAP Select data from SAP table PYC_D_PY_MSG into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP PYC_D_PY_MSG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PYC_D_PY_MSG. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the PYC_D_PY_MSG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_PYC_D_PY_MSG TYPE STANDARD TABLE OF PYC_D_PY_MSG,
WA_PYC_D_PY_MSG TYPE PYC_D_PY_MSG,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PYC_D_PY_MSG> TYPE PYC_D_PY_MSG.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_PYC_D_PY_MSG.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM PYC_D_PY_MSG
INTO TABLE IT_PYC_D_PY_MSG.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM PYC_D_PY_MSG
* INTO TABLE @DATA(IT_PYC_D_PY_MSG2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PYC_D_PY_MSG INDEX 1 INTO DATA(WA_PYC_D_PY_MSG2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PYC_D_PY_MSG ASSIGNING <PYC_D_PY_MSG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<PYC_D_PY_MSG>-MANDT = 1.
<PYC_D_PY_MSG>-PERNR = 1.
<PYC_D_PY_MSG>-IABKR = 1.
<PYC_D_PY_MSG>-IAPER = 1.
<PYC_D_PY_MSG>-IENDD = 1.
ENDLOOP. LOOP AT IT_PYC_D_PY_MSG INTO WA_PYC_D_PY_MSG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_PYC_D_PY_MSG-INPTY, sy-vline,
WA_PYC_D_PY_MSG-INPID, sy-vline,
WA_PYC_D_PY_MSG-TEST_RES, sy-vline,
WA_PYC_D_PY_MSG-SEQNR, sy-vline,
WA_PYC_D_PY_MSG-MSGPO, sy-vline,
WA_PYC_D_PY_MSG-ABKRS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PYC_D_PY_MSG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PYC_D_PY_MSG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PYC_D_PY_MSG INTO WA_PYC_D_PY_MSG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit PIDEX, internal->external for field PERSONID CALL FUNCTION 'CONVERSION_EXIT_PIDEX_OUTPUT' EXPORTING input = WA_PYC_D_PY_MSG-PERSONID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PYC_D_PY_MSG-PERSONID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PYC_D_PY_MSG_STR,
MANDT TYPE STRING,
PERNR TYPE STRING,
IABKR TYPE STRING,
IAPER TYPE STRING,
IENDD TYPE STRING,
INPTY TYPE STRING,
INPID TYPE STRING,
TEST_RES TYPE STRING,
SEQNR TYPE STRING,
MSGPO TYPE STRING,
ABKRS TYPE STRING,
PAPER TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
PAYTY TYPE STRING,
PAYID TYPE STRING,
OCRSN TYPE STRING,
CHKDT TYPE STRING,
PERSONID TYPE STRING,
FUNCO TYPE STRING,
FNUMB TYPE STRING,
PARM1 TYPE STRING,
PARM2 TYPE STRING,
PARM3 TYPE STRING,
PARM4 TYPE STRING,
PROTO TYPE STRING,
SKIP TYPE STRING,
AS_TEXT TYPE STRING,
MSGID TYPE STRING,
MSGTY TYPE STRING,
MSGNO TYPE STRING,
MSGV1 TYPE STRING,
MSGV2 TYPE STRING,
MSGV3 TYPE STRING,
MSGV4 TYPE STRING,
TLEVEL TYPE STRING,
MESSAGE TYPE STRING,
TEXT1 TYPE STRING,
TLENGTH1 TYPE STRING,
TINTENSIV1 TYPE STRING,
TEXT2 TYPE STRING,
TLENGTH2 TYPE STRING,
TINTENSIV2 TYPE STRING,
TEXT3 TYPE STRING,
TLENGTH3 TYPE STRING,
TINTENSIV3 TYPE STRING,
TEXT4 TYPE STRING,
TLENGTH4 TYPE STRING,
TINTENSIV4 TYPE STRING,
EMPTY_LINES TYPE STRING,
LC_USER TYPE STRING,
LC_DT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PYC_D_PY_MSG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PYC_D_PY_MSG_STR-MANDT sy-vline
WA_PYC_D_PY_MSG_STR-PERNR sy-vline
WA_PYC_D_PY_MSG_STR-IABKR sy-vline
WA_PYC_D_PY_MSG_STR-IAPER sy-vline
WA_PYC_D_PY_MSG_STR-IENDD sy-vline
WA_PYC_D_PY_MSG_STR-INPTY sy-vline
WA_PYC_D_PY_MSG_STR-INPID sy-vline
WA_PYC_D_PY_MSG_STR-TEST_RES sy-vline
WA_PYC_D_PY_MSG_STR-SEQNR sy-vline
WA_PYC_D_PY_MSG_STR-MSGPO sy-vline
WA_PYC_D_PY_MSG_STR-ABKRS sy-vline
WA_PYC_D_PY_MSG_STR-PAPER sy-vline
WA_PYC_D_PY_MSG_STR-BEGDA sy-vline
WA_PYC_D_PY_MSG_STR-ENDDA sy-vline
WA_PYC_D_PY_MSG_STR-PAYTY sy-vline
WA_PYC_D_PY_MSG_STR-PAYID sy-vline
WA_PYC_D_PY_MSG_STR-OCRSN sy-vline
WA_PYC_D_PY_MSG_STR-CHKDT sy-vline
WA_PYC_D_PY_MSG_STR-PERSONID sy-vline
WA_PYC_D_PY_MSG_STR-FUNCO sy-vline
WA_PYC_D_PY_MSG_STR-FNUMB sy-vline
WA_PYC_D_PY_MSG_STR-PARM1 sy-vline
WA_PYC_D_PY_MSG_STR-PARM2 sy-vline
WA_PYC_D_PY_MSG_STR-PARM3 sy-vline
WA_PYC_D_PY_MSG_STR-PARM4 sy-vline
WA_PYC_D_PY_MSG_STR-PROTO sy-vline
WA_PYC_D_PY_MSG_STR-SKIP sy-vline
WA_PYC_D_PY_MSG_STR-AS_TEXT sy-vline
WA_PYC_D_PY_MSG_STR-MSGID sy-vline
WA_PYC_D_PY_MSG_STR-MSGTY sy-vline
WA_PYC_D_PY_MSG_STR-MSGNO sy-vline
WA_PYC_D_PY_MSG_STR-MSGV1 sy-vline
WA_PYC_D_PY_MSG_STR-MSGV2 sy-vline
WA_PYC_D_PY_MSG_STR-MSGV3 sy-vline
WA_PYC_D_PY_MSG_STR-MSGV4 sy-vline
WA_PYC_D_PY_MSG_STR-TLEVEL sy-vline
WA_PYC_D_PY_MSG_STR-MESSAGE sy-vline
WA_PYC_D_PY_MSG_STR-TEXT1 sy-vline
WA_PYC_D_PY_MSG_STR-TLENGTH1 sy-vline
WA_PYC_D_PY_MSG_STR-TINTENSIV1 sy-vline
WA_PYC_D_PY_MSG_STR-TEXT2 sy-vline
WA_PYC_D_PY_MSG_STR-TLENGTH2 sy-vline
WA_PYC_D_PY_MSG_STR-TINTENSIV2 sy-vline
WA_PYC_D_PY_MSG_STR-TEXT3 sy-vline
WA_PYC_D_PY_MSG_STR-TLENGTH3 sy-vline
WA_PYC_D_PY_MSG_STR-TINTENSIV3 sy-vline
WA_PYC_D_PY_MSG_STR-TEXT4 sy-vline
WA_PYC_D_PY_MSG_STR-TLENGTH4 sy-vline
WA_PYC_D_PY_MSG_STR-TINTENSIV4 sy-vline
WA_PYC_D_PY_MSG_STR-EMPTY_LINES sy-vline
WA_PYC_D_PY_MSG_STR-LC_USER sy-vline
WA_PYC_D_PY_MSG_STR-LC_DT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.
