ABAP Select data from SAP table PVRCPD_DYNP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PVRCPD_DYNP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PVRCPD_DYNP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PVRCPD_DYNP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PVRCPD_DYNP TYPE STANDARD TABLE OF PVRCPD_DYNP,
      WA_PVRCPD_DYNP TYPE PVRCPD_DYNP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PVRCPD_DYNP> TYPE PVRCPD_DYNP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PVRCPD_DYNP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PVRCPD_DYNP
  INTO TABLE IT_PVRCPD_DYNP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PVRCPD_DYNP
*  INTO TABLE @DATA(IT_PVRCPD_DYNP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PVRCPD_DYNP INDEX 1 INTO DATA(WA_PVRCPD_DYNP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PVRCPD_DYNP ASSIGNING <PVRCPD_DYNP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PVRCPD_DYNP>-PVCDCNT = 1.
<PVRCPD_DYNP>-AENNR = 1.
<PVRCPD_DYNP>-ISTATUS = 1.
<PVRCPD_DYNP>-STATUS_CHG_COUNT = 1.
<PVRCPD_DYNP>-OBJNR = 1.
ENDLOOP.

LOOP AT IT_PVRCPD_DYNP INTO WA_PVRCPD_DYNP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PVRCPD_DYNP-ISTATUS_OLD, sy-vline,
WA_PVRCPD_DYNP-RCPDCNT, sy-vline,
WA_PVRCPD_DYNP-RCPVERS, sy-vline,
WA_PVRCPD_DYNP-VALFROM, sy-vline,
WA_PVRCPD_DYNP-VALTO, sy-vline,
WA_PVRCPD_DYNP-LOTMIN, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PVRCPD_DYNP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PVRCPD_DYNP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PVRCPD_DYNP INTO WA_PVRCPD_DYNP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field AENNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PVRCPD_DYNP-AENNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVRCPD_DYNP-AENNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field LOTUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PVRCPD_DYNP-LOTUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVRCPD_DYNP-LOTUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field PV_MAT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PVRCPD_DYNP-PV_MAT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVRCPD_DYNP-PV_MAT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PROJECT CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_PVRCPD_DYNP-PROJECT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVRCPD_DYNP-PROJECT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field REFLANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_PVRCPD_DYNP-REFLANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVRCPD_DYNP-REFLANG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PVNAME CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PVRCPD_DYNP-PVNAME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVRCPD_DYNP-PVNAME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PVRCPD_DYNP-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVRCPD_DYNP-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PVRCPD_DYNP-PLNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVRCPD_DYNP-PLNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ALNAL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PVRCPD_DYNP-ALNAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVRCPD_DYNP-ALNAL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PVRCPD_DYNP_STR,
PVCDCNT TYPE STRING,
AENNR TYPE STRING,
ISTATUS TYPE STRING,
STATUS_CHG_COUNT TYPE STRING,
OBJNR TYPE STRING,
ISTATUS_OLD TYPE STRING,
RCPDCNT TYPE STRING,
RCPVERS TYPE STRING,
VALFROM TYPE STRING,
VALTO TYPE STRING,
LOTMIN TYPE STRING,
LOTMAX TYPE STRING,
LOTUNIT TYPE STRING,
PV_PLANT TYPE STRING,
PV_MAT TYPE STRING,
PV_NR TYPE STRING,
OTYPE_ORGID TYPE STRING,
REALO TYPE STRING,
RCP_TIMSTMP TYPE STRING,
RCP_CREADAT TYPE STRING,
RCP_CREABY TYPE STRING,
RCP_CHNGDAT TYPE STRING,
RCP_CHNGBY TYPE STRING,
REFQUANT TYPE STRING,
PROJECT TYPE STRING,
DEV_TIME TYPE STRING,
PROD_TIME TYPE STRING,
CONF_FLAG TYPE STRING,
REFLANG TYPE STRING,
PVTXCNT TYPE STRING,
RESCREATXCNT TYPE STRING,
COPY_FROM TYPE STRING,
COPY_FROM_RCP TYPE STRING,
PREF_RCP_FLG TYPE STRING,
CONS_FLG TYPE STRING,
STDVAR TYPE STRING,
MANDT TYPE STRING,
PVGUID TYPE STRING,
PVNAME TYPE STRING,
NAMEID TYPE STRING,
PNGUID TYPE STRING,
PVTYPE TYPE STRING,
APPLOBJ_TYPE TYPE STRING,
TIMSTMP TYPE STRING,
HISTFLG TYPE STRING,
CREADAT TYPE STRING,
CREABY TYPE STRING,
CHNGDAT TYPE STRING,
CHNGBY TYPE STRING,
LOGSYS TYPE STRING,
ESTATUS_LINE TYPE STRING,
ISTATUS_TEXT TYPE STRING,
ISTATUS_TEXT30 TYPE STRING,
REASON_CHG TYPE STRING,
PLNTY TYPE STRING,
PLNNR TYPE STRING,
ALNAL TYPE STRING,
REALO_TEXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_PVRCPD_DYNP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PVRCPD_DYNP_STR-PVCDCNT sy-vline
WA_PVRCPD_DYNP_STR-AENNR sy-vline
WA_PVRCPD_DYNP_STR-ISTATUS sy-vline
WA_PVRCPD_DYNP_STR-STATUS_CHG_COUNT sy-vline
WA_PVRCPD_DYNP_STR-OBJNR sy-vline
WA_PVRCPD_DYNP_STR-ISTATUS_OLD sy-vline
WA_PVRCPD_DYNP_STR-RCPDCNT sy-vline
WA_PVRCPD_DYNP_STR-RCPVERS sy-vline
WA_PVRCPD_DYNP_STR-VALFROM sy-vline
WA_PVRCPD_DYNP_STR-VALTO sy-vline
WA_PVRCPD_DYNP_STR-LOTMIN sy-vline
WA_PVRCPD_DYNP_STR-LOTMAX sy-vline
WA_PVRCPD_DYNP_STR-LOTUNIT sy-vline
WA_PVRCPD_DYNP_STR-PV_PLANT sy-vline
WA_PVRCPD_DYNP_STR-PV_MAT sy-vline
WA_PVRCPD_DYNP_STR-PV_NR sy-vline
WA_PVRCPD_DYNP_STR-OTYPE_ORGID sy-vline
WA_PVRCPD_DYNP_STR-REALO sy-vline
WA_PVRCPD_DYNP_STR-RCP_TIMSTMP sy-vline
WA_PVRCPD_DYNP_STR-RCP_CREADAT sy-vline
WA_PVRCPD_DYNP_STR-RCP_CREABY sy-vline
WA_PVRCPD_DYNP_STR-RCP_CHNGDAT sy-vline
WA_PVRCPD_DYNP_STR-RCP_CHNGBY sy-vline
WA_PVRCPD_DYNP_STR-REFQUANT sy-vline
WA_PVRCPD_DYNP_STR-PROJECT sy-vline
WA_PVRCPD_DYNP_STR-DEV_TIME sy-vline
WA_PVRCPD_DYNP_STR-PROD_TIME sy-vline
WA_PVRCPD_DYNP_STR-CONF_FLAG sy-vline
WA_PVRCPD_DYNP_STR-REFLANG sy-vline
WA_PVRCPD_DYNP_STR-PVTXCNT sy-vline
WA_PVRCPD_DYNP_STR-RESCREATXCNT sy-vline
WA_PVRCPD_DYNP_STR-COPY_FROM sy-vline
WA_PVRCPD_DYNP_STR-COPY_FROM_RCP sy-vline
WA_PVRCPD_DYNP_STR-PREF_RCP_FLG sy-vline
WA_PVRCPD_DYNP_STR-CONS_FLG sy-vline
WA_PVRCPD_DYNP_STR-STDVAR sy-vline
WA_PVRCPD_DYNP_STR-MANDT sy-vline
WA_PVRCPD_DYNP_STR-PVGUID sy-vline
WA_PVRCPD_DYNP_STR-PVNAME sy-vline
WA_PVRCPD_DYNP_STR-NAMEID sy-vline
WA_PVRCPD_DYNP_STR-PNGUID sy-vline
WA_PVRCPD_DYNP_STR-PVTYPE sy-vline
WA_PVRCPD_DYNP_STR-APPLOBJ_TYPE sy-vline
WA_PVRCPD_DYNP_STR-TIMSTMP sy-vline
WA_PVRCPD_DYNP_STR-HISTFLG sy-vline
WA_PVRCPD_DYNP_STR-CREADAT sy-vline
WA_PVRCPD_DYNP_STR-CREABY sy-vline
WA_PVRCPD_DYNP_STR-CHNGDAT sy-vline
WA_PVRCPD_DYNP_STR-CHNGBY sy-vline
WA_PVRCPD_DYNP_STR-LOGSYS sy-vline
WA_PVRCPD_DYNP_STR-ESTATUS_LINE sy-vline
WA_PVRCPD_DYNP_STR-ISTATUS_TEXT sy-vline
WA_PVRCPD_DYNP_STR-ISTATUS_TEXT30 sy-vline
WA_PVRCPD_DYNP_STR-REASON_CHG sy-vline
WA_PVRCPD_DYNP_STR-PLNTY sy-vline
WA_PVRCPD_DYNP_STR-PLNNR sy-vline
WA_PVRCPD_DYNP_STR-ALNAL sy-vline
WA_PVRCPD_DYNP_STR-REALO_TEXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.