ABAP Select data from SAP table PVERSMBOMCRCHECK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP PVERSMBOMCRCHECK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to PVERSMBOMCRCHECK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the PVERSMBOMCRCHECK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_PVERSMBOMCRCHECK TYPE STANDARD TABLE OF PVERSMBOMCRCHECK,
      WA_PVERSMBOMCRCHECK TYPE PVERSMBOMCRCHECK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <PVERSMBOMCRCHECK> TYPE PVERSMBOMCRCHECK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_PVERSMBOMCRCHECK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM PVERSMBOMCRCHECK
  INTO TABLE IT_PVERSMBOMCRCHECK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM PVERSMBOMCRCHECK
*  INTO TABLE @DATA(IT_PVERSMBOMCRCHECK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_PVERSMBOMCRCHECK INDEX 1 INTO DATA(WA_PVERSMBOMCRCHECK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_PVERSMBOMCRCHECK ASSIGNING <PVERSMBOMCRCHECK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<PVERSMBOMCRCHECK>-MANDT = 1.
<PVERSMBOMCRCHECK>-BILLOFMATERIAL = 1.
<PVERSMBOMCRCHECK>-BILLOFMATERIALCATEGORY = 1.
<PVERSMBOMCRCHECK>-BILLOFMATERIALVARIANT = 1.
<PVERSMBOMCRCHECK>-BILLOFMATERIALVERSION = 1.
ENDLOOP.

LOOP AT IT_PVERSMBOMCRCHECK INTO WA_PVERSMBOMCRCHECK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_PVERSMBOMCRCHECK-PLANT, sy-vline,
WA_PVERSMBOMCRCHECK-BOMALTERNATIVETEXT, sy-vline,
WA_PVERSMBOMCRCHECK-BOMGROUP, sy-vline,
WA_PVERSMBOMCRCHECK-BOMHEADERBASEUNIT, sy-vline,
WA_PVERSMBOMCRCHECK-BOMHEADERINTERNALCHANGECOUNT, sy-vline,
WA_PVERSMBOMCRCHECK-BOMHEADERQUANTITYINBASEUNIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_PVERSMBOMCRCHECK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_PVERSMBOMCRCHECK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_PVERSMBOMCRCHECK INTO WA_PVERSMBOMCRCHECK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit NUMCV, internal->external for field BILLOFMATERIAL CALL FUNCTION 'CONVERSION_EXIT_NUMCV_OUTPUT' EXPORTING input = WA_PVERSMBOMCRCHECK-BILLOFMATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVERSMBOMCRCHECK-BILLOFMATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BILLOFMATERIALVARIANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PVERSMBOMCRCHECK-BILLOFMATERIALVARIANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVERSMBOMCRCHECK-BILLOFMATERIALVARIANT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field BOMHEADERBASEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_PVERSMBOMCRCHECK-BOMHEADERBASEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVERSMBOMCRCHECK-BOMHEADERBASEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHGTOENGINEERINGCHGDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PVERSMBOMCRCHECK-CHGTOENGINEERINGCHGDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVERSMBOMCRCHECK-CHGTOENGINEERINGCHGDOCUMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ENGINEERINGCHANGEDOCUMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PVERSMBOMCRCHECK-ENGINEERINGCHANGEDOCUMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVERSMBOMCRCHECK-ENGINEERINGCHANGEDOCUMENT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field MATERIAL CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_PVERSMBOMCRCHECK-MATERIAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVERSMBOMCRCHECK-MATERIAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field CHANGERECORD CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_PVERSMBOMCRCHECK-CHANGERECORD IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_PVERSMBOMCRCHECK-CHANGERECORD.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_PVERSMBOMCRCHECK_STR,
MANDT TYPE STRING,
BILLOFMATERIAL TYPE STRING,
BILLOFMATERIALCATEGORY TYPE STRING,
BILLOFMATERIALVARIANT TYPE STRING,
BILLOFMATERIALVERSION TYPE STRING,
PLANT TYPE STRING,
BOMALTERNATIVETEXT TYPE STRING,
BOMGROUP TYPE STRING,
BOMHEADERBASEUNIT TYPE STRING,
BOMHEADERINTERNALCHANGECOUNT TYPE STRING,
BOMHEADERQUANTITYINBASEUNIT TYPE STRING,
BOMHEADERTEXT TYPE STRING,
BOMISTOBEDELETED TYPE STRING,
BOMPRIORITIZEDVERSION TYPE STRING,
BOMTECHNICALTYPE TYPE STRING,
BOMUSAGEPRIORITY TYPE STRING,
BOMVERSIONSTATUS TYPE STRING,
BILLOFMATERIALAUTHSNGRP TYPE STRING,
BILLOFMATERIALHEADERUUID TYPE STRING,
BILLOFMATERIALSTATUS TYPE STRING,
BILLOFMATERIALUUID TYPE STRING,
BILLOFMATERIALVARIANTUSAGE TYPE STRING,
CHGTOENGINEERINGCHGDOCUMENT TYPE STRING,
CREATEDBYUSER TYPE STRING,
DOCUMENTISCREATEDBYCAD TYPE STRING,
ENGINEERINGCHANGEDOCUMENT TYPE STRING,
HEADERVALIDITYENDDATE TYPE STRING,
HEADERVALIDITYSTARTDATE TYPE STRING,
ISALE TYPE STRING,
ISCONFIGUREDMATERIAL TYPE STRING,
ISLATESTBOMVERSION TYPE STRING,
ISMARKEDFORDELETION TYPE STRING,
ISMULTIPLEBOMALT TYPE STRING,
LABORATORYORDESIGNOFFICE TYPE STRING,
LASTCHANGEDATE TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
MATFROMLOTSIZEQUANTITY TYPE STRING,
MATERIAL TYPE STRING,
ISVERSIONBILLOFMATERIAL TYPE STRING,
CHANGERECORD TYPE STRING,
CHGRECDASSGD TYPE STRING,
ISMATERIALUNITIZED TYPE STRING,
CHANGERECORDUUID TYPE STRING,
RECORDCREATIONDATE TYPE STRING,
MATERIALTOLOTSIZEQUANTITY TYPE STRING,END OF T_EKKO_STR. DATA: WA_PVERSMBOMCRCHECK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_PVERSMBOMCRCHECK_STR-MANDT sy-vline
WA_PVERSMBOMCRCHECK_STR-BILLOFMATERIAL sy-vline
WA_PVERSMBOMCRCHECK_STR-BILLOFMATERIALCATEGORY sy-vline
WA_PVERSMBOMCRCHECK_STR-BILLOFMATERIALVARIANT sy-vline
WA_PVERSMBOMCRCHECK_STR-BILLOFMATERIALVERSION sy-vline
WA_PVERSMBOMCRCHECK_STR-PLANT sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMALTERNATIVETEXT sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMGROUP sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMHEADERBASEUNIT sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMHEADERINTERNALCHANGECOUNT sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMHEADERQUANTITYINBASEUNIT sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMHEADERTEXT sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMISTOBEDELETED sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMPRIORITIZEDVERSION sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMTECHNICALTYPE sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMUSAGEPRIORITY sy-vline
WA_PVERSMBOMCRCHECK_STR-BOMVERSIONSTATUS sy-vline
WA_PVERSMBOMCRCHECK_STR-BILLOFMATERIALAUTHSNGRP sy-vline
WA_PVERSMBOMCRCHECK_STR-BILLOFMATERIALHEADERUUID sy-vline
WA_PVERSMBOMCRCHECK_STR-BILLOFMATERIALSTATUS sy-vline
WA_PVERSMBOMCRCHECK_STR-BILLOFMATERIALUUID sy-vline
WA_PVERSMBOMCRCHECK_STR-BILLOFMATERIALVARIANTUSAGE sy-vline
WA_PVERSMBOMCRCHECK_STR-CHGTOENGINEERINGCHGDOCUMENT sy-vline
WA_PVERSMBOMCRCHECK_STR-CREATEDBYUSER sy-vline
WA_PVERSMBOMCRCHECK_STR-DOCUMENTISCREATEDBYCAD sy-vline
WA_PVERSMBOMCRCHECK_STR-ENGINEERINGCHANGEDOCUMENT sy-vline
WA_PVERSMBOMCRCHECK_STR-HEADERVALIDITYENDDATE sy-vline
WA_PVERSMBOMCRCHECK_STR-HEADERVALIDITYSTARTDATE sy-vline
WA_PVERSMBOMCRCHECK_STR-ISALE sy-vline
WA_PVERSMBOMCRCHECK_STR-ISCONFIGUREDMATERIAL sy-vline
WA_PVERSMBOMCRCHECK_STR-ISLATESTBOMVERSION sy-vline
WA_PVERSMBOMCRCHECK_STR-ISMARKEDFORDELETION sy-vline
WA_PVERSMBOMCRCHECK_STR-ISMULTIPLEBOMALT sy-vline
WA_PVERSMBOMCRCHECK_STR-LABORATORYORDESIGNOFFICE sy-vline
WA_PVERSMBOMCRCHECK_STR-LASTCHANGEDATE sy-vline
WA_PVERSMBOMCRCHECK_STR-LASTCHANGEDBYUSER sy-vline
WA_PVERSMBOMCRCHECK_STR-MATFROMLOTSIZEQUANTITY sy-vline
WA_PVERSMBOMCRCHECK_STR-MATERIAL sy-vline
WA_PVERSMBOMCRCHECK_STR-ISVERSIONBILLOFMATERIAL sy-vline
WA_PVERSMBOMCRCHECK_STR-CHANGERECORD sy-vline
WA_PVERSMBOMCRCHECK_STR-CHGRECDASSGD sy-vline
WA_PVERSMBOMCRCHECK_STR-ISMATERIALUNITIZED sy-vline
WA_PVERSMBOMCRCHECK_STR-CHANGERECORDUUID sy-vline
WA_PVERSMBOMCRCHECK_STR-RECORDCREATIONDATE sy-vline
WA_PVERSMBOMCRCHECK_STR-MATERIALTOLOTSIZEQUANTITY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.